{"id":{"repo_id":"cornell","oai_identifier":"oai:ecommons.cornell.edu:1813/70044"},"canonical_url":"https://search.ndltd.org/etd/cornell/oai:ecommons.cornell.edu:1813/70044","repository":{"repo_id":"cornell","name":"Cornell University","base_url":"https://ecommons.cornell.edu/server/oai/request"},"display":{"title":"LAB-ON-A-CHIP TECHNIQUES FOR APPLICATIONS IN SINGLE MOLECULE BIOPHYSICS AND NEUROBIOLOGY","abstract":"“Lab-on-a-chip” technology refers to the concept of shrinking normally macroscopic laboratory instruments down to the micrometer or nanometer scale, with “on-chip” specifically normally referring to silicon chip-based devices (including glass, a.k.a silicon dioxide). This thesis has two lab-on-a-chip components. The first part is developing new lab-on-a-chip technology. Optical tweezers are typically room-sized optics setups designed for precision (nanometer-scale) manipulation of single molecules. On-chip high-throughput optical tweezers (analogous to conveyor belts) were fabricated and optimized on coin-sized silicon-based devices. For the second part, existing lab-on-a-chip technology was used to conduct a toxicology study. Specifically planar microelectrode arrays were used to characterize the toxicity of next generation nanomedicine nanoparticles. Historical electrode arrays are large devices implanted into an animal brain, but microelectrode arrays are small chip-based arrays that can directly probe single neurons plated in culture in the microelectrode dish (neuron culture is similar to a miniature two-dimensional “brain”) , thus shrinking the electrode array technology down to the microscale.","abstract_html":"“Lab-on-a-chip” technology refers to the concept of shrinking normally macroscopic laboratory instruments down to the micrometer or nanometer scale, with “on-chip” specifically normally referring to silicon chip-based devices (including glass, a.k.a silicon dioxide). This thesis has two lab-on-a-chip components. The first part is developing new lab-on-a-chip technology. Optical tweezers are typically room-sized optics setups designed for precision (nanometer-scale) manipulation of single molecules. On-chip high-throughput optical tweezers (analogous to conveyor belts) were fabricated and optimized on coin-sized silicon-based devices. For the second part, existing lab-on-a-chip technology was used to conduct a toxicology study. Specifically planar microelectrode arrays were used to characterize the toxicity of next generation nanomedicine nanoparticles. Historical electrode arrays are large devices implanted into an animal brain, but microelectrode arrays are small chip-based arrays that can directly probe single neurons plated in culture in the microelectrode dish (neuron culture is similar to a miniature two-dimensional “brain”) , thus shrinking the electrode array technology down to the microscale.","abstract_has_math":false,"creators":["Badman, Ryan P."],"institution":null,"degree_name":"Ph. D., Physics","degree_level":"Doctor of Philosophy","degree_discipline":"Physics","degree_department":null,"school":null,"contributors":[],"advisors":[],"committee_chairs":["Wang, Michelle D."],"committee_members":["Wang, Z. Jane","Franck, Carl Peter"],"year":2019,"date_issued":"2019-12","date_published":"2019-12","updated_at":"2026-11-19T03:20:50Z","subjects":["microcylinder","nanoparticle","nanophotonics","nanotoxicology","optical trapping","refractive index"],"languages":["en"],"rights":["Attribution-NoDerivatives 4.0 International"],"rights_urls":["https://creativecommons.org/licenses/by-nd/4.0/"],"identifier_entries":[{"key":"dc:identifier.doi","label":"DOI","values":["https://doi.org/10.7298/mwvk-3a07"],"render_values":[{"text":"https://doi.org/10.7298/mwvk-3a07","href":"https://doi.org/10.7298/mwvk-3a07","code":true}]},{"key":"dc:identifier.bibid","label":"Dc Identifier Bibid","values":["13119762"],"render_values":[{"text":"13119762","href":null,"code":true}]},{"key":"dc:identifier.other","label":"Dc Identifier Other","values":["ProQuest Submission ID: 11785","ProQuest Publication ID: 27545340"],"render_values":[{"text":"ProQuest Submission ID: 11785","href":null,"code":true},{"text":"ProQuest Publication ID: 27545340","href":null,"code":true}]}],"person_identifier_entries":[]},"links":{"outbound_url":"https://hdl.handle.net/1813/70044","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"https://hdl.handle.net/1813/70044","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://ecommons.cornell.edu/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Aecommons.cornell.edu%3A1813%2F70044","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.chair","label":"Chair","values":["Wang, Michelle D."]},{"key":"dc:contributor.committeemember","label":"Committee Member","values":["Wang, Z. Jane","Franck, Carl Peter"]},{"key":"dc:creator","label":"Author","values":["Badman, Ryan P."]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2020-06-23T18:01:05Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2022-01-17T07:00:13Z"]},{"key":"dc:date.issued","label":"Date","values":["2019-12"]},{"key":"dc:relation.uri","label":"Dc Relation URI","values":["https://newcatalog.library.cornell.edu/catalog/13119762"]},{"key":"dc:type","label":"Dc Type","values":["dissertation or thesis"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Physics"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Doctor of Philosophy"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Ph. D., Physics"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["microcylinder","nanoparticle","nanophotonics","nanotoxicology","optical trapping","refractive index"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["en"]},{"key":"dc:rights","label":"Dc Rights","values":["Attribution-NoDerivatives 4.0 International"]},{"key":"dc:rights.uri","label":"Rights URI","values":["https://creativecommons.org/licenses/by-nd/4.0/"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.bibid","label":"Dc Identifier Bibid","values":["13119762"]},{"key":"dc:identifier.doi","label":"DOI","values":["https://doi.org/10.7298/mwvk-3a07"]},{"key":"dc:identifier.other","label":"Dc Identifier Other","values":["ProQuest Submission ID: 11785","ProQuest Publication ID: 27545340"]},{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://hdl.handle.net/1813/70044"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"cerif:openaire","label":"Cerif Openaire","values":["<Publication xmlns=\"https://www.openaire.eu/cerif-profile/1.1/\" id=\"4541e3a8-6448-4374-8b85-dc71db5fd441\"> <Type xmlns=\"https://www.openaire.eu/cerif-profile/vocab/COAR_Publication_Types\">http://purl.org/coar/resource_type/c_1843</Type> <Language>en</Language> <Title>LAB-ON-A-CHIP TECHNIQUES FOR APPLICATIONS IN SINGLE MOLECULE BIOPHYSICS AND NEUROBIOLOGY</Title> <PublishedIn> <Publication> </Publication> </PublishedIn> <PublicationDate>2019-12</PublicationDate> <DOI>https://doi.org/10.7298/mwvk-3a07</DOI> <Authors> <Author> <DisplayName>Badman, Ryan P.</DisplayName> <Affiliation> <OrgUnit> </OrgUnit> </Affiliation> </Author> </Authors> <Editors> </Editors> <Publishers> <Publisher> <OrgUnit /> </Publisher> </Publishers> <License>https://creativecommons.org/licenses/by-nd/4.0/</License> <Keyword>microcylinder</Keyword> <Keyword>nanoparticle</Keyword> <Keyword>nanophotonics</Keyword> <Keyword>nanotoxicology</Keyword> <Keyword>optical trapping</Keyword> <Keyword>refractive index</Keyword> <Abstract>“Lab-on-a-chip” technology refers to the concept of shrinking normally macroscopic laboratory instruments down to the micrometer or nanometer scale, with “on-chip” specifically normally referring to silicon chip-based devices (including glass, a.k.a silicon dioxide). This thesis has two lab-on-a-chip components. The first part is developing new lab-on-a-chip technology. Optical tweezers are typically room-sized optics setups designed for precision (nanometer-scale) manipulation of single molecules. On-chip high-throughput optical tweezers (analogous to conveyor belts) were fabricated and optimized on coin-sized silicon-based devices. For the second part, existing lab-on-a-chip technology was used to conduct a toxicology study. Specifically planar microelectrode arrays were used to characterize the toxicity of next generation nanomedicine nanoparticles. Historical electrode arrays are large devices implanted into an animal brain, but microelectrode arrays are small chip-based arrays that can directly probe single neurons plated in culture in the microelectrode dish (neuron culture is similar to a miniature two-dimensional “brain”) , thus shrinking the electrode array technology down to the microscale.</Abstract> <Access xmlns=\"http://purl.org/coar/access_right\" > </Access> </Publication>"]},{"key":"cris:virtual.author","label":"Cris Virtual Author","values":["Badman, Ryan P."]},{"key":"cris:virtualsource.collection","label":"Cris Virtualsource Collection","values":["5893a6ea-7af3-41d7-abc6-04bcd26ab5df"]},{"key":"dc:description","label":"Description","values":["151 pages"]},{"key":"dc:description.abstract","label":"Abstract","values":["“Lab-on-a-chip” technology refers to the concept of shrinking normally macroscopic laboratory instruments down to the micrometer or nanometer scale, with “on-chip” specifically normally referring to silicon chip-based devices (including glass, a.k.a silicon dioxide). This thesis has two lab-on-a-chip components. The first part is developing new lab-on-a-chip technology. Optical tweezers are typically room-sized optics setups designed for precision (nanometer-scale) manipulation of single molecules. On-chip high-throughput optical tweezers (analogous to conveyor belts) were fabricated and optimized on coin-sized silicon-based devices. For the second part, existing lab-on-a-chip technology was used to conduct a toxicology study. Specifically planar microelectrode arrays were used to characterize the toxicity of next generation nanomedicine nanoparticles. Historical electrode arrays are large devices implanted into an animal brain, but microelectrode arrays are small chip-based arrays that can directly probe single neurons plated in culture in the microelectrode dish (neuron culture is similar to a miniature two-dimensional “brain”) , thus shrinking the electrode array technology down to the microscale."]},{"key":"dc:description.collection","label":"Dc Description Collection","values":["Cornell Theses and Dissertations"]},{"key":"dc:format.mimetype","label":"Dc Format Mimetype","values":["application/pdf"]},{"key":"dcterms:license","label":"Dcterms License","values":["https://hdl.handle.net/1813/59810"]},{"key":"dc:title","label":"Title","values":["LAB-ON-A-CHIP TECHNIQUES FOR APPLICATIONS IN SINGLE MOLECULE BIOPHYSICS AND NEUROBIOLOGY"]},{"key":"dspace:entity.type","label":"Dspace Entity Type","values":["Publication"]},{"key":"others:access_status","label":"Others Access Status","values":["open.access"]}]}],"canonical_facts":{"cerif:openaire":["<Publication xmlns=\"https://www.openaire.eu/cerif-profile/1.1/\" id=\"4541e3a8-6448-4374-8b85-dc71db5fd441\"> <Type xmlns=\"https://www.openaire.eu/cerif-profile/vocab/COAR_Publication_Types\">http://purl.org/coar/resource_type/c_1843</Type> <Language>en</Language> <Title>LAB-ON-A-CHIP TECHNIQUES FOR APPLICATIONS IN SINGLE MOLECULE BIOPHYSICS AND NEUROBIOLOGY</Title> <PublishedIn> <Publication> </Publication> </PublishedIn> <PublicationDate>2019-12</PublicationDate> <DOI>https://doi.org/10.7298/mwvk-3a07</DOI> <Authors> <Author> <DisplayName>Badman, Ryan P.</DisplayName> <Affiliation> <OrgUnit> </OrgUnit> </Affiliation> </Author> </Authors> <Editors> </Editors> <Publishers> <Publisher> <OrgUnit /> </Publisher> </Publishers> <License>https://creativecommons.org/licenses/by-nd/4.0/</License> <Keyword>microcylinder</Keyword> <Keyword>nanoparticle</Keyword> <Keyword>nanophotonics</Keyword> <Keyword>nanotoxicology</Keyword> <Keyword>optical trapping</Keyword> <Keyword>refractive index</Keyword> <Abstract>“Lab-on-a-chip” technology refers to the concept of shrinking normally macroscopic laboratory instruments down to the micrometer or nanometer scale, with “on-chip” specifically normally referring to silicon chip-based devices (including glass, a.k.a silicon dioxide). This thesis has two lab-on-a-chip components. The first part is developing new lab-on-a-chip technology. Optical tweezers are typically room-sized optics setups designed for precision (nanometer-scale) manipulation of single molecules. On-chip high-throughput optical tweezers (analogous to conveyor belts) were fabricated and optimized on coin-sized silicon-based devices. For the second part, existing lab-on-a-chip technology was used to conduct a toxicology study. Specifically planar microelectrode arrays were used to characterize the toxicity of next generation nanomedicine nanoparticles. Historical electrode arrays are large devices implanted into an animal brain, but microelectrode arrays are small chip-based arrays that can directly probe single neurons plated in culture in the microelectrode dish (neuron culture is similar to a miniature two-dimensional “brain”) , thus shrinking the electrode array technology down to the microscale.</Abstract> <Access xmlns=\"http://purl.org/coar/access_right\" > </Access> </Publication>"],"cris:virtual.author":["Badman, Ryan P."],"cris:virtualsource.collection":["5893a6ea-7af3-41d7-abc6-04bcd26ab5df"],"dc:contributor.chair":["Wang, Michelle D."],"dc:contributor.committeemember":["Wang, Z. Jane","Franck, Carl Peter"],"dc:creator":["Badman, Ryan P."],"dc:date.accessioned":["2020-06-23T18:01:05Z"],"dc:date.available":["2022-01-17T07:00:13Z"],"dc:date.issued":["2019-12"],"dc:description":["151 pages"],"dc:description.abstract":["“Lab-on-a-chip” technology refers to the concept of shrinking normally macroscopic laboratory instruments down to the micrometer or nanometer scale, with “on-chip” specifically normally referring to silicon chip-based devices (including glass, a.k.a silicon dioxide). This thesis has two lab-on-a-chip components. The first part is developing new lab-on-a-chip technology. Optical tweezers are typically room-sized optics setups designed for precision (nanometer-scale) manipulation of single molecules. On-chip high-throughput optical tweezers (analogous to conveyor belts) were fabricated and optimized on coin-sized silicon-based devices. For the second part, existing lab-on-a-chip technology was used to conduct a toxicology study. Specifically planar microelectrode arrays were used to characterize the toxicity of next generation nanomedicine nanoparticles. Historical electrode arrays are large devices implanted into an animal brain, but microelectrode arrays are small chip-based arrays that can directly probe single neurons plated in culture in the microelectrode dish (neuron culture is similar to a miniature two-dimensional “brain”) , thus shrinking the electrode array technology down to the microscale."],"dc:description.collection":["Cornell Theses and Dissertations"],"dc:format.mimetype":["application/pdf"],"dc:identifier.bibid":["13119762"],"dc:identifier.doi":["https://doi.org/10.7298/mwvk-3a07"],"dc:identifier.other":["ProQuest Submission ID: 11785","ProQuest Publication ID: 27545340"],"dc:identifier.uri":["https://hdl.handle.net/1813/70044"],"dc:language.iso":["en"],"dc:relation.uri":["https://newcatalog.library.cornell.edu/catalog/13119762"],"dc:rights":["Attribution-NoDerivatives 4.0 International"],"dc:rights.uri":["https://creativecommons.org/licenses/by-nd/4.0/"],"dc:subject":["microcylinder","nanoparticle","nanophotonics","nanotoxicology","optical trapping","refractive index"],"dcterms:license":["https://hdl.handle.net/1813/59810"],"dc:title":["LAB-ON-A-CHIP TECHNIQUES FOR APPLICATIONS IN SINGLE MOLECULE BIOPHYSICS AND NEUROBIOLOGY"],"dc:type":["dissertation or thesis"],"dspace:entity.type":["Publication"],"others:access_status":["open.access"],"thesis:degree_discipline":["Physics"],"thesis:degree_level":["Doctor of Philosophy"],"thesis:degree_name":["Ph. D., Physics"]},"updated_at":"2026-11-19T03:20:50Z"}