{"id":{"repo_id":"cornell","oai_identifier":"oai:ecommons.cornell.edu:1813/70278"},"canonical_url":"https://search.ndltd.org/etd/cornell/oai:ecommons.cornell.edu:1813/70278","repository":{"repo_id":"cornell","name":"Cornell University","base_url":"https://ecommons.cornell.edu/server/oai/request"},"display":{"title":"Improving the Assisted Bidirectional Glenn Design for Better Ejector Pump Effect and Lower SVC Pressure","abstract":"The assisted bidirectional Glenn (ABG) procedure was proposed to address the drawbacks of the modified Blalock-Taussig shunt (mBTS) and the bidirectional Glenn (BGD) procedures, as an alternative to first and second stage palliation for neonates with single-ventricle physiology. This thesis introduces a modified ABG (mABG) design to address previous ABG drawbacks of high SVC pressure. The performances are compared with realistic 3-dimensional multiscale simulations. Two simulation methods developed to improve accuracy and reduce costs are introduced: an adaptive mesh refinement method and an aortic pressure regulatory method. A parametric optimization study shows that the optimal nozzle area is around 16% of the SVC cross-sectional area, the optimal nozzle width and the optimal shunt diameter are both 3.5 mm. Simulations show the mABG was able to preserve all advantages of the original ABG procedure while reducing the SVC pressure to 4.3 mmHg at normal PVR. There is no significant improvement in the SVC pressure for high PVR, motivating more extensive paramedic studies.","abstract_html":"The assisted bidirectional Glenn (ABG) procedure was proposed to address the drawbacks of the modified Blalock-Taussig shunt (mBTS) and the bidirectional Glenn (BGD) procedures, as an alternative to first and second stage palliation for neonates with single-ventricle physiology. This thesis introduces a modified ABG (mABG) design to address previous ABG drawbacks of high SVC pressure. The performances are compared with realistic 3-dimensional multiscale simulations. Two simulation methods developed to improve accuracy and reduce costs are introduced: an adaptive mesh refinement method and an aortic pressure regulatory method. A parametric optimization study shows that the optimal nozzle area is around 16% of the SVC cross-sectional area, the optimal nozzle width and the optimal shunt diameter are both 3.5 mm. Simulations show the mABG was able to preserve all advantages of the original ABG procedure while reducing the SVC pressure to 4.3 mmHg at normal PVR. There is no significant improvement in the SVC pressure for high PVR, motivating more extensive paramedic studies.","abstract_has_math":false,"creators":["Jia, Dongjie"],"institution":"Cornell University","degree_name":"M.S., Mechanical Engineering","degree_level":"Master of Science","degree_discipline":"Mechanical Engineering","degree_department":null,"school":null,"contributors":[],"advisors":[],"committee_chairs":["Esmaily Moghadam, Mahdi"],"committee_members":["Antaki, James"],"year":2020,"date_issued":"2020-05","date_published":"2020-05","updated_at":"2026-11-19T03:21:11Z","subjects":["Assisted bidirectional Glenn","Computational fluid dynamics","Hypoplastic left heart syndrome"],"languages":["en"],"rights":[],"rights_urls":[],"identifier_entries":[{"key":"dc:identifier.doi","label":"DOI","values":["https://doi.org/10.7298/w849-c929"],"render_values":[{"text":"https://doi.org/10.7298/w849-c929","href":"https://doi.org/10.7298/w849-c929","code":true}]},{"key":"dc:identifier.bibid","label":"Dc Identifier Bibid","values":["13254351"],"render_values":[{"text":"13254351","href":null,"code":true}]},{"key":"dc:identifier.other","label":"Dc Identifier Other","values":["ProQuest Submission ID: 10898","ProQuest Publication ID: 27993439"],"render_values":[{"text":"ProQuest Submission ID: 10898","href":null,"code":true},{"text":"ProQuest Publication ID: 27993439","href":null,"code":true}]}],"person_identifier_entries":[]},"links":{"outbound_url":"https://hdl.handle.net/1813/70278","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"https://hdl.handle.net/1813/70278","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://ecommons.cornell.edu/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Aecommons.cornell.edu%3A1813%2F70278","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.chair","label":"Chair","values":["Esmaily Moghadam, Mahdi"]},{"key":"dc:contributor.committeemember","label":"Committee Member","values":["Antaki, James"]},{"key":"dc:creator","label":"Author","values":["Jia, Dongjie"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2020-08-10T20:07:31Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2022-06-08T06:00:25Z"]},{"key":"dc:date.issued","label":"Date","values":["2020-05"]},{"key":"dc:relation.uri","label":"Dc Relation URI","values":["https://catalog.library.cornell.edu/catalog/13254351"]},{"key":"dc:type","label":"Dc Type","values":["dissertation or thesis"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Mechanical Engineering"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Master of Science"]},{"key":"thesis:degree_name","label":"Degree Name","values":["M.S., Mechanical Engineering"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["Cornell University"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Assisted bidirectional Glenn","Computational fluid dynamics","Hypoplastic left heart syndrome"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["en"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.bibid","label":"Dc Identifier Bibid","values":["13254351"]},{"key":"dc:identifier.doi","label":"DOI","values":["https://doi.org/10.7298/w849-c929"]},{"key":"dc:identifier.other","label":"Dc Identifier Other","values":["ProQuest Submission ID: 10898","ProQuest Publication ID: 27993439"]},{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://hdl.handle.net/1813/70278"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"cerif:openaire","label":"Cerif Openaire","values":["<Publication xmlns=\"https://www.openaire.eu/cerif-profile/1.1/\" id=\"56f24b62-45bd-43db-8854-44e8f9232b0c\"> <Type xmlns=\"https://www.openaire.eu/cerif-profile/vocab/COAR_Publication_Types\">http://purl.org/coar/resource_type/c_1843</Type> <Language>en</Language> <Title>Improving the Assisted Bidirectional Glenn Design for Better Ejector Pump Effect and Lower SVC Pressure</Title> <PublishedIn> <Publication> </Publication> </PublishedIn> <PublicationDate>2020-05</PublicationDate> <DOI>https://doi.org/10.7298/w849-c929</DOI> <Authors> <Author> <DisplayName>Jia, Dongjie</DisplayName> <Affiliation> <OrgUnit> </OrgUnit> </Affiliation> </Author> </Authors> <Editors> </Editors> <Publishers> <Publisher> <OrgUnit /> </Publisher> </Publishers> <Keyword>Assisted bidirectional Glenn</Keyword> <Keyword>Computational fluid dynamics</Keyword> <Keyword>Hypoplastic left heart syndrome</Keyword> <Abstract>The assisted bidirectional Glenn (ABG) procedure was proposed to address the drawbacks of the modified Blalock-Taussig shunt (mBTS) and the bidirectional Glenn (BGD) procedures, as an alternative to first and second stage palliation for neonates with single-ventricle physiology. This thesis introduces a modified ABG (mABG) design to address previous ABG drawbacks of high SVC pressure. The performances are compared with realistic 3-dimensional multiscale simulations. Two simulation methods developed to improve accuracy and reduce costs are introduced: an adaptive mesh refinement method and an aortic pressure regulatory method. A parametric optimization study shows that the optimal nozzle area is around 16% of the SVC cross-sectional area, the optimal nozzle width and the optimal shunt diameter are both 3.5 mm. Simulations show the mABG was able to preserve all advantages of the original ABG procedure while reducing the SVC pressure to 4.3 mmHg at normal PVR. There is no significant improvement in the SVC pressure for high PVR, motivating more extensive paramedic studies.</Abstract> <Access xmlns=\"http://purl.org/coar/access_right\" > </Access> </Publication>"]},{"key":"cris:virtual.author","label":"Cris Virtual Author","values":["Jia, Dongjie"]},{"key":"cris:virtualsource.collection","label":"Cris Virtualsource Collection","values":["5893a6ea-7af3-41d7-abc6-04bcd26ab5df"]},{"key":"dc:description","label":"Description","values":["59 pages"]},{"key":"dc:description.abstract","label":"Abstract","values":["The assisted bidirectional Glenn (ABG) procedure was proposed to address the drawbacks of the modified Blalock-Taussig shunt (mBTS) and the bidirectional Glenn (BGD) procedures, as an alternative to first and second stage palliation for neonates with single-ventricle physiology. This thesis introduces a modified ABG (mABG) design to address previous ABG drawbacks of high SVC pressure. The performances are compared with realistic 3-dimensional multiscale simulations. Two simulation methods developed to improve accuracy and reduce costs are introduced: an adaptive mesh refinement method and an aortic pressure regulatory method. A parametric optimization study shows that the optimal nozzle area is around 16% of the SVC cross-sectional area, the optimal nozzle width and the optimal shunt diameter are both 3.5 mm. Simulations show the mABG was able to preserve all advantages of the original ABG procedure while reducing the SVC pressure to 4.3 mmHg at normal PVR. There is no significant improvement in the SVC pressure for high PVR, motivating more extensive paramedic studies."]},{"key":"dc:description.collection","label":"Dc Description Collection","values":["Cornell Theses and Dissertations"]},{"key":"dc:format.mimetype","label":"Dc Format Mimetype","values":["application/pdf"]},{"key":"dcterms:license","label":"Dcterms License","values":["https://hdl.handle.net/1813/59810"]},{"key":"dc:title","label":"Title","values":["Improving the Assisted Bidirectional Glenn Design for Better Ejector Pump Effect and Lower SVC Pressure"]},{"key":"dspace:entity.type","label":"Dspace Entity Type","values":["Publication"]},{"key":"others:access_status","label":"Others Access Status","values":["open.access"]}]}],"canonical_facts":{"cerif:openaire":["<Publication xmlns=\"https://www.openaire.eu/cerif-profile/1.1/\" id=\"56f24b62-45bd-43db-8854-44e8f9232b0c\"> <Type xmlns=\"https://www.openaire.eu/cerif-profile/vocab/COAR_Publication_Types\">http://purl.org/coar/resource_type/c_1843</Type> <Language>en</Language> <Title>Improving the Assisted Bidirectional Glenn Design for Better Ejector Pump Effect and Lower SVC Pressure</Title> <PublishedIn> <Publication> </Publication> </PublishedIn> <PublicationDate>2020-05</PublicationDate> <DOI>https://doi.org/10.7298/w849-c929</DOI> <Authors> <Author> <DisplayName>Jia, Dongjie</DisplayName> <Affiliation> <OrgUnit> </OrgUnit> </Affiliation> </Author> </Authors> <Editors> </Editors> <Publishers> <Publisher> <OrgUnit /> </Publisher> </Publishers> <Keyword>Assisted bidirectional Glenn</Keyword> <Keyword>Computational fluid dynamics</Keyword> <Keyword>Hypoplastic left heart syndrome</Keyword> <Abstract>The assisted bidirectional Glenn (ABG) procedure was proposed to address the drawbacks of the modified Blalock-Taussig shunt (mBTS) and the bidirectional Glenn (BGD) procedures, as an alternative to first and second stage palliation for neonates with single-ventricle physiology. This thesis introduces a modified ABG (mABG) design to address previous ABG drawbacks of high SVC pressure. The performances are compared with realistic 3-dimensional multiscale simulations. Two simulation methods developed to improve accuracy and reduce costs are introduced: an adaptive mesh refinement method and an aortic pressure regulatory method. A parametric optimization study shows that the optimal nozzle area is around 16% of the SVC cross-sectional area, the optimal nozzle width and the optimal shunt diameter are both 3.5 mm. Simulations show the mABG was able to preserve all advantages of the original ABG procedure while reducing the SVC pressure to 4.3 mmHg at normal PVR. There is no significant improvement in the SVC pressure for high PVR, motivating more extensive paramedic studies.</Abstract> <Access xmlns=\"http://purl.org/coar/access_right\" > </Access> </Publication>"],"cris:virtual.author":["Jia, Dongjie"],"cris:virtualsource.collection":["5893a6ea-7af3-41d7-abc6-04bcd26ab5df"],"dc:contributor.chair":["Esmaily Moghadam, Mahdi"],"dc:contributor.committeemember":["Antaki, James"],"dc:creator":["Jia, Dongjie"],"dc:date.accessioned":["2020-08-10T20:07:31Z"],"dc:date.available":["2022-06-08T06:00:25Z"],"dc:date.issued":["2020-05"],"dc:description":["59 pages"],"dc:description.abstract":["The assisted bidirectional Glenn (ABG) procedure was proposed to address the drawbacks of the modified Blalock-Taussig shunt (mBTS) and the bidirectional Glenn (BGD) procedures, as an alternative to first and second stage palliation for neonates with single-ventricle physiology. This thesis introduces a modified ABG (mABG) design to address previous ABG drawbacks of high SVC pressure. The performances are compared with realistic 3-dimensional multiscale simulations. Two simulation methods developed to improve accuracy and reduce costs are introduced: an adaptive mesh refinement method and an aortic pressure regulatory method. A parametric optimization study shows that the optimal nozzle area is around 16% of the SVC cross-sectional area, the optimal nozzle width and the optimal shunt diameter are both 3.5 mm. Simulations show the mABG was able to preserve all advantages of the original ABG procedure while reducing the SVC pressure to 4.3 mmHg at normal PVR. There is no significant improvement in the SVC pressure for high PVR, motivating more extensive paramedic studies."],"dc:description.collection":["Cornell Theses and Dissertations"],"dc:format.mimetype":["application/pdf"],"dc:identifier.bibid":["13254351"],"dc:identifier.doi":["https://doi.org/10.7298/w849-c929"],"dc:identifier.other":["ProQuest Submission ID: 10898","ProQuest Publication ID: 27993439"],"dc:identifier.uri":["https://hdl.handle.net/1813/70278"],"dc:language.iso":["en"],"dc:relation.uri":["https://catalog.library.cornell.edu/catalog/13254351"],"dc:subject":["Assisted bidirectional Glenn","Computational fluid dynamics","Hypoplastic left heart syndrome"],"dcterms:license":["https://hdl.handle.net/1813/59810"],"dc:title":["Improving the Assisted Bidirectional Glenn Design for Better Ejector Pump Effect and Lower SVC Pressure"],"dc:type":["dissertation or thesis"],"dspace:entity.type":["Publication"],"others:access_status":["open.access"],"thesis:degree_discipline":["Mechanical Engineering"],"thesis:degree_level":["Master of Science"],"thesis:degree_name":["M.S., Mechanical Engineering"],"thesis:institution_name":["Cornell University"]},"updated_at":"2026-11-19T03:21:11Z"}