{"id":{"repo_id":"cranfield","oai_identifier":"oai:dspace.lib.cranfield.ac.uk:1826/18380"},"canonical_url":"https://search.ndltd.org/etd/cranfield/oai:dspace.lib.cranfield.ac.uk:1826/18380","repository":{"repo_id":"cranfield","name":"Cranfield University","base_url":"https://dspace.lib.cranfield.ac.uk/server/oai/request"},"display":{"title":"Modelling and evaluation of 2-amino-2-methyl-1-propanol (amp) based process for CO₂ capture from natural gas-fired power plant.","abstract":"It is widely accepted that emissions of CO₂, which is a major greenhouse gas, are the primary cause of climate change. This has led to the development of carbon capture and storage (CCS) technologies in which CO₂ is captured from large-scale point sources such as power plants. However, retrofits of carbon capture plants result in high-efficiency penalties, which have been reported to fall in the range of 7–12% points in the case of post-combustion capture (PCC) from natural gas combined cycle (NGCC) power plants. Therefore, a reduction of these efficiency losses is a high priority in order to deploy CCS at a large scale. At the moment, chemical solvent scrubbing using amines, such as monoethanolamine (MEA), is considered as the most mature option for CO₂ capture from fossil fuel-fired power plants. However, due to high heat requirements for solvent regeneration, the use of substitute solvents has been considered. This thesis investigates the capture of CO₂ from the flue gas of a NGCC power plant using 2-amino-2-methyl-1-propanol (AMP) solvent, the aim of which was to identify and evaluate opportunities for improvement. The methodology adopted in achieving the set objectives is subdivided into three sections. Firstly, a rate-based model for AMP pilot-scale PCC plant was developed with default parameters in Aspen Plus®, validated with published experimental data, and scaled up to commercial scale. Afterwards, the AMP-based plant was retrofitted into the 474 MWe NGCC power plant model, and an economic analysis was performed with the MEA-based PCC plant used as a benchmark. Lastly, the AMP-based CO₂ capture plant with solvent storage was retrofitted into the NGCC. A thermodynamic assessment revealed that the AMP-based process resulted in 25.6% lower reboiler duty, compared to that of the MEA-based process. Regardless of the superior thermodynamic performance, the economic performance of the AMP-based process was shown to be better than that of the MEA-based process only for make-up rates below 0.03% of total flowrate in the system. Furthermore, results revealed that the process with solvent storage was found to increase the profit by approximately 1% compared to that without solvent storage. Hence, this thesis showed that the use of AMP as a solvent in chemical solvent scrubbing is a good option, but may not be the most feasible option from the economic standpoint","abstract_html":"It is widely accepted that emissions of CO₂, which is a major greenhouse gas, are the primary cause of climate change. This has led to the development of carbon capture and storage (CCS) technologies in which CO₂ is captured from large-scale point sources such as power plants. However, retrofits of carbon capture plants result in high-efficiency penalties, which have been reported to fall in the range of 7–12% points in the case of post-combustion capture (PCC) from natural gas combined cycle (NGCC) power plants. Therefore, a reduction of these efficiency losses is a high priority in order to deploy CCS at a large scale. At the moment, chemical solvent scrubbing using amines, such as monoethanolamine (MEA), is considered as the most mature option for CO₂ capture from fossil fuel-fired power plants. However, due to high heat requirements for solvent regeneration, the use of substitute solvents has been considered. This thesis investigates the capture of CO₂ from the flue gas of a NGCC power plant using 2-amino-2-methyl-1-propanol (AMP) solvent, the aim of which was to identify and evaluate opportunities for improvement. The methodology adopted in achieving the set objectives is subdivided into three sections. Firstly, a rate-based model for AMP pilot-scale PCC plant was developed with default parameters in Aspen Plus®, validated with published experimental data, and scaled up to commercial scale. Afterwards, the AMP-based plant was retrofitted into the 474 MWe NGCC power plant model, and an economic analysis was performed with the MEA-based PCC plant used as a benchmark. Lastly, the AMP-based CO₂ capture plant with solvent storage was retrofitted into the NGCC. A thermodynamic assessment revealed that the AMP-based process resulted in 25.6% lower reboiler duty, compared to that of the MEA-based process. Regardless of the superior thermodynamic performance, the economic performance of the AMP-based process was shown to be better than that of the MEA-based process only for make-up rates below 0.03% of total flowrate in the system. Furthermore, results revealed that the process with solvent storage was found to increase the profit by approximately 1% compared to that without solvent storage. Hence, this thesis showed that the use of AMP as a solvent in chemical solvent scrubbing is a good option, but may not be the most feasible option from the economic standpoint","abstract_has_math":false,"creators":["Osagie, Ebuwa Iyore"],"institution":null,"degree_name":null,"degree_level":null,"degree_discipline":null,"degree_department":null,"school":null,"contributors":[],"advisors":["Manovic, Vasilije","Hanak, Dawid P."],"committee_chairs":[],"committee_members":[],"year":2018,"date_issued":"2018-08","date_published":"2018-08","updated_at":"2026-11-26T14:25:51Z","subjects":["Post-combustion capture","2-amino-2-methyl-1-propanol","natural gas combined cycle","modelling and simulation","solvent storage","economic analysis"],"languages":["en"],"rights":["© Cranfield University, 2015. All rights reserved. No part of this publication may be reproduced without the written permission of the copyright holder."],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"https://dspace.lib.cranfield.ac.uk/handle/1826/18380","outbound_label":"Repository record","outbound_source":"dc:identifier.uri","record_url":"https://dspace.lib.cranfield.ac.uk/handle/1826/18380","record_label":"Repository record","record_kind":"record","record_source":"dc:identifier.uri","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Acranfield%3Aoai%3Adspace.lib.cranfield.ac.uk%3A1826%2F18380","prefix":"oai_dc"},"source_record":{"url":"https://dspace.lib.cranfield.ac.uk/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Adspace.lib.cranfield.ac.uk%3A1826%2F18380","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Manovic, Vasilije","Hanak, Dawid P."]},{"key":"dc:creator","label":"Author","values":["Osagie, Ebuwa Iyore"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2022-08-31T09:23:27Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2022-08-31T09:23:27Z"]},{"key":"dc:date.issued","label":"Date","values":["2018-08"]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]},{"key":"dc:type.qualificationlevel","label":"Dc Type Qualificationlevel","values":["Doctoral"]},{"key":"dc:type.qualificationname","label":"Dc Type Qualificationname","values":["PhD"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Post-combustion capture","2-amino-2-methyl-1-propanol","natural gas combined cycle","modelling and simulation","solvent storage","economic analysis"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["en"]},{"key":"dc:rights","label":"Dc Rights","values":["© Cranfield University, 2015. All rights reserved. No part of this publication may be reproduced without the written permission of the copyright holder."]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://dspace.lib.cranfield.ac.uk/handle/1826/18380"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["It is widely accepted that emissions of CO₂, which is a major greenhouse gas, are the primary cause of climate change. This has led to the development of carbon capture and storage (CCS) technologies in which CO₂ is captured from large-scale point sources such as power plants. However, retrofits of carbon capture plants result in high-efficiency penalties, which have been reported to fall in the range of 7–12% points in the case of post-combustion capture (PCC) from natural gas combined cycle (NGCC) power plants. Therefore, a reduction of these efficiency losses is a high priority in order to deploy CCS at a large scale. At the moment, chemical solvent scrubbing using amines, such as monoethanolamine (MEA), is considered as the most mature option for CO₂ capture from fossil fuel-fired power plants. However, due to high heat requirements for solvent regeneration, the use of substitute solvents has been considered. This thesis investigates the capture of CO₂ from the flue gas of a NGCC power plant using 2-amino-2-methyl-1-propanol (AMP) solvent, the aim of which was to identify and evaluate opportunities for improvement. The methodology adopted in achieving the set objectives is subdivided into three sections. Firstly, a rate-based model for AMP pilot-scale PCC plant was developed with default parameters in Aspen Plus®, validated with published experimental data, and scaled up to commercial scale. Afterwards, the AMP-based plant was retrofitted into the 474 MWe NGCC power plant model, and an economic analysis was performed with the MEA-based PCC plant used as a benchmark. Lastly, the AMP-based CO₂ capture plant with solvent storage was retrofitted into the NGCC. A thermodynamic assessment revealed that the AMP-based process resulted in 25.6% lower reboiler duty, compared to that of the MEA-based process. Regardless of the superior thermodynamic performance, the economic performance of the AMP-based process was shown to be better than that of the MEA-based process only for make-up rates below 0.03% of total flowrate in the system. Furthermore, results revealed that the process with solvent storage was found to increase the profit by approximately 1% compared to that without solvent storage. Hence, this thesis showed that the use of AMP as a solvent in chemical solvent scrubbing is a good option, but may not be the most feasible option from the economic standpoint"]},{"key":"dc:description.coursename","label":"Dc Description Coursename","values":["PhD in Energy and Power"]},{"key":"dc:title","label":"Title","values":["Modelling and evaluation of 2-amino-2-methyl-1-propanol (amp) based process for CO₂ capture from natural gas-fired power plant."]},{"key":"others:access_status","label":"Others Access Status","values":["open.access"]}]}],"canonical_facts":{"dc:contributor.advisor":["Manovic, Vasilije","Hanak, Dawid P."],"dc:creator":["Osagie, Ebuwa Iyore"],"dc:date.accessioned":["2022-08-31T09:23:27Z"],"dc:date.available":["2022-08-31T09:23:27Z"],"dc:date.issued":["2018-08"],"dc:description.abstract":["It is widely accepted that emissions of CO₂, which is a major greenhouse gas, are the primary cause of climate change. This has led to the development of carbon capture and storage (CCS) technologies in which CO₂ is captured from large-scale point sources such as power plants. However, retrofits of carbon capture plants result in high-efficiency penalties, which have been reported to fall in the range of 7–12% points in the case of post-combustion capture (PCC) from natural gas combined cycle (NGCC) power plants. Therefore, a reduction of these efficiency losses is a high priority in order to deploy CCS at a large scale. At the moment, chemical solvent scrubbing using amines, such as monoethanolamine (MEA), is considered as the most mature option for CO₂ capture from fossil fuel-fired power plants. However, due to high heat requirements for solvent regeneration, the use of substitute solvents has been considered. This thesis investigates the capture of CO₂ from the flue gas of a NGCC power plant using 2-amino-2-methyl-1-propanol (AMP) solvent, the aim of which was to identify and evaluate opportunities for improvement. The methodology adopted in achieving the set objectives is subdivided into three sections. Firstly, a rate-based model for AMP pilot-scale PCC plant was developed with default parameters in Aspen Plus®, validated with published experimental data, and scaled up to commercial scale. Afterwards, the AMP-based plant was retrofitted into the 474 MWe NGCC power plant model, and an economic analysis was performed with the MEA-based PCC plant used as a benchmark. Lastly, the AMP-based CO₂ capture plant with solvent storage was retrofitted into the NGCC. A thermodynamic assessment revealed that the AMP-based process resulted in 25.6% lower reboiler duty, compared to that of the MEA-based process. Regardless of the superior thermodynamic performance, the economic performance of the AMP-based process was shown to be better than that of the MEA-based process only for make-up rates below 0.03% of total flowrate in the system. Furthermore, results revealed that the process with solvent storage was found to increase the profit by approximately 1% compared to that without solvent storage. Hence, this thesis showed that the use of AMP as a solvent in chemical solvent scrubbing is a good option, but may not be the most feasible option from the economic standpoint"],"dc:description.coursename":["PhD in Energy and Power"],"dc:identifier.uri":["https://dspace.lib.cranfield.ac.uk/handle/1826/18380"],"dc:language.iso":["en"],"dc:rights":["© Cranfield University, 2015. All rights reserved. No part of this publication may be reproduced without the written permission of the copyright holder."],"dc:subject":["Post-combustion capture","2-amino-2-methyl-1-propanol","natural gas combined cycle","modelling and simulation","solvent storage","economic analysis"],"dc:title":["Modelling and evaluation of 2-amino-2-methyl-1-propanol (amp) based process for CO₂ capture from natural gas-fired power plant."],"dc:type":["Thesis"],"dc:type.qualificationlevel":["Doctoral"],"dc:type.qualificationname":["PhD"],"others:access_status":["open.access"]},"updated_at":"2026-11-26T14:25:51Z"}