{"id":{"repo_id":"cranfield","oai_identifier":"oai:dspace.lib.cranfield.ac.uk:1826/19538"},"canonical_url":"https://search.ndltd.org/etd/cranfield/oai:dspace.lib.cranfield.ac.uk:1826/19538","repository":{"repo_id":"cranfield","name":"Cranfield University","base_url":"https://dspace.lib.cranfield.ac.uk/server/oai/request"},"display":{"title":"Towards the molecular diagnosis of bladder and colorectal cancer : Analysis of CD44 exon splicing","abstract":"The literature suggests that CD44 has the potential to be used as a non-invasive tumour specific marker for early detection and monitoring. The gene transcript can undergo alternative splicing, leading to the production of a number of isoforms and it has been noted that in neoplastic states this splicing becomes abberant, leading to the production of a number o f variant isoforms. The aim of this study was to analyse CD44 variant expression with the goal o f reaching a platform from which a non- invasive assay for routine clinical use could be produced. In this study, the analysis o f exon junction splicing in bladder cancer has also led to the finding of a tumour specific junction expressed in 64% o f tumours studied. This exon junction (5/11) was found to be the same as that expressed in colorectal cancer. Though mRNA based assays would provide a satisfactory method for exon junction identification, a protein based approach would provide the platform for a more robust assay. Translation of gene expression data led to the design of a short synthetic peptide which overlapped the 5/11 junction, and this was used to produce a novel polyclonal antibody for this transitional epitope. The resulting polyclonal antibody was affinity purified and used in a pilot study of 5/11 expression in bladder and colorectal tumours. In bladder tumours the antibody demonstrated an overall specificity o f 76.5% and an overal sensitivity of 73.1 %, comparable to current commercially available early detection assays. In a Dukes staged colorectal cancer study, no link between stage and grade was noted, but the antibody gave an overall specificity of 76%. Though further analysis is required, it is thought the 5/11 antibody may prove to be a useful tool in the development o f a sensitive and specific assay for the non-invasive detection of bladder and colorectal cancer.","abstract_html":"The literature suggests that CD44 has the potential to be used as a non-invasive tumour specific marker for early detection and monitoring. The gene transcript can undergo alternative splicing, leading to the production of a number of isoforms and it has been noted that in neoplastic states this splicing becomes abberant, leading to the production of a number o f variant isoforms. The aim of this study was to analyse CD44 variant expression with the goal o f reaching a platform from which a non- invasive assay for routine clinical use could be produced. In this study, the analysis o f exon junction splicing in bladder cancer has also led to the finding of a tumour specific junction expressed in 64% o f tumours studied. This exon junction (5/11) was found to be the same as that expressed in colorectal cancer. Though mRNA based assays would provide a satisfactory method for exon junction identification, a protein based approach would provide the platform for a more robust assay. Translation of gene expression data led to the design of a short synthetic peptide which overlapped the 5/11 junction, and this was used to produce a novel polyclonal antibody for this transitional epitope. The resulting polyclonal antibody was affinity purified and used in a pilot study of 5/11 expression in bladder and colorectal tumours. In bladder tumours the antibody demonstrated an overall specificity o f 76.5% and an overal sensitivity of 73.1 %, comparable to current commercially available early detection assays. In a Dukes staged colorectal cancer study, no link between stage and grade was noted, but the antibody gave an overall specificity of 76%. Though further analysis is required, it is thought the 5/11 antibody may prove to be a useful tool in the development o f a sensitive and specific assay for the non-invasive detection of bladder and colorectal cancer.","abstract_has_math":false,"creators":["Morgan, Sarah Louise"],"institution":null,"degree_name":null,"degree_level":null,"degree_discipline":null,"degree_department":null,"school":null,"contributors":[],"advisors":["Woodman, Anthony C."],"committee_chairs":[],"committee_members":[],"year":2002,"date_issued":"2002-08","date_published":"2002-08","updated_at":"2026-11-26T14:26:48Z","subjects":[],"languages":["en"],"rights":["© Cranfield University, 2015. All rights reserved. No part of this publication may be reproduced without the written permission of the copyright holder."],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"https://dspace.lib.cranfield.ac.uk/handle/1826/19538","outbound_label":"Repository record","outbound_source":"dc:identifier.uri","record_url":"https://dspace.lib.cranfield.ac.uk/handle/1826/19538","record_label":"Repository record","record_kind":"record","record_source":"dc:identifier.uri","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Acranfield%3Aoai%3Adspace.lib.cranfield.ac.uk%3A1826%2F19538","prefix":"oai_dc"},"source_record":{"url":"https://dspace.lib.cranfield.ac.uk/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Adspace.lib.cranfield.ac.uk%3A1826%2F19538","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Woodman, Anthony C."]},{"key":"dc:creator","label":"Author","values":["Morgan, Sarah Louise"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2023-04-20T15:11:23Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2023-04-20T15:11:23Z"]},{"key":"dc:date.issued","label":"Date","values":["2002-08"]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["en"]},{"key":"dc:rights","label":"Dc Rights","values":["© Cranfield University, 2015. All rights reserved. No part of this publication may be reproduced without the written permission of the copyright holder."]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://dspace.lib.cranfield.ac.uk/handle/1826/19538"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["The literature suggests that CD44 has the potential to be used as a non-invasive tumour specific marker for early detection and monitoring. The gene transcript can undergo alternative splicing, leading to the production of a number of isoforms and it has been noted that in neoplastic states this splicing becomes abberant, leading to the production of a number o f variant isoforms. The aim of this study was to analyse CD44 variant expression with the goal o f reaching a platform from which a non- invasive assay for routine clinical use could be produced. In this study, the analysis o f exon junction splicing in bladder cancer has also led to the finding of a tumour specific junction expressed in 64% o f tumours studied. This exon junction (5/11) was found to be the same as that expressed in colorectal cancer. Though mRNA based assays would provide a satisfactory method for exon junction identification, a protein based approach would provide the platform for a more robust assay. Translation of gene expression data led to the design of a short synthetic peptide which overlapped the 5/11 junction, and this was used to produce a novel polyclonal antibody for this transitional epitope. The resulting polyclonal antibody was affinity purified and used in a pilot study of 5/11 expression in bladder and colorectal tumours. In bladder tumours the antibody demonstrated an overall specificity o f 76.5% and an overal sensitivity of 73.1 %, comparable to current commercially available early detection assays. In a Dukes staged colorectal cancer study, no link between stage and grade was noted, but the antibody gave an overall specificity of 76%. Though further analysis is required, it is thought the 5/11 antibody may prove to be a useful tool in the development o f a sensitive and specific assay for the non-invasive detection of bladder and colorectal cancer."]},{"key":"dc:description.coursename","label":"Dc Description Coursename","values":["PhD"]},{"key":"dc:title","label":"Title","values":["Towards the molecular diagnosis of bladder and colorectal cancer : Analysis of CD44 exon splicing"]},{"key":"others:access_status","label":"Others Access Status","values":["open.access"]}]}],"canonical_facts":{"dc:contributor.advisor":["Woodman, Anthony C."],"dc:creator":["Morgan, Sarah Louise"],"dc:date.accessioned":["2023-04-20T15:11:23Z"],"dc:date.available":["2023-04-20T15:11:23Z"],"dc:date.issued":["2002-08"],"dc:description.abstract":["The literature suggests that CD44 has the potential to be used as a non-invasive tumour specific marker for early detection and monitoring. The gene transcript can undergo alternative splicing, leading to the production of a number of isoforms and it has been noted that in neoplastic states this splicing becomes abberant, leading to the production of a number o f variant isoforms. The aim of this study was to analyse CD44 variant expression with the goal o f reaching a platform from which a non- invasive assay for routine clinical use could be produced. In this study, the analysis o f exon junction splicing in bladder cancer has also led to the finding of a tumour specific junction expressed in 64% o f tumours studied. This exon junction (5/11) was found to be the same as that expressed in colorectal cancer. Though mRNA based assays would provide a satisfactory method for exon junction identification, a protein based approach would provide the platform for a more robust assay. Translation of gene expression data led to the design of a short synthetic peptide which overlapped the 5/11 junction, and this was used to produce a novel polyclonal antibody for this transitional epitope. The resulting polyclonal antibody was affinity purified and used in a pilot study of 5/11 expression in bladder and colorectal tumours. In bladder tumours the antibody demonstrated an overall specificity o f 76.5% and an overal sensitivity of 73.1 %, comparable to current commercially available early detection assays. In a Dukes staged colorectal cancer study, no link between stage and grade was noted, but the antibody gave an overall specificity of 76%. Though further analysis is required, it is thought the 5/11 antibody may prove to be a useful tool in the development o f a sensitive and specific assay for the non-invasive detection of bladder and colorectal cancer."],"dc:description.coursename":["PhD"],"dc:identifier.uri":["https://dspace.lib.cranfield.ac.uk/handle/1826/19538"],"dc:language.iso":["en"],"dc:rights":["© Cranfield University, 2015. All rights reserved. No part of this publication may be reproduced without the written permission of the copyright holder."],"dc:title":["Towards the molecular diagnosis of bladder and colorectal cancer : Analysis of CD44 exon splicing"],"dc:type":["Thesis"],"others:access_status":["open.access"]},"updated_at":"2026-11-26T14:26:48Z"}