{"id":{"repo_id":"cranfield","oai_identifier":"oai:dspace.lib.cranfield.ac.uk:1826/22865"},"canonical_url":"https://search.ndltd.org/etd/cranfield/oai:dspace.lib.cranfield.ac.uk:1826/22865","repository":{"repo_id":"cranfield","name":"Cranfield University","base_url":"https://dspace.lib.cranfield.ac.uk/server/oai/request"},"display":{"title":"Rotary mount design for a chromatic confocal sensor, involving additive manufacturing and an opened air bearing","abstract":"In the field of high energy physics, the characterisation and positioning in space of a wire with a diameter of 0.1 mm is one of the steps to increase the precision of future accelerators’ pre-alignment. This reference wire is measured within a high accuracy Coordinate Measuring Machine (CMM) to reduce its positioning uncertainty. No sensor could measure the wire position within the targeted uncertainty. This thesis addresses this issue by proposing a design for the Shape Evaluating Sensor: High Accuracy & Touchless (SESHAT). The SESHAT operates a chromatic confocal sensor. The sensor is fixed to a rotor with a radial opening to allow the stretched wire to traverse it. This rotor is guided by a high precision air bearing controlled by a piezoelectric actuator. The mass limit for the stylus system of the CMM entailed the additive manufacturing of a hollow rotor. The high likelihood of particles on the wire surface involved a form deviation capability for the SESHAT, to reduce position measurement uncertainty. The aim of the research was to design a sensor enabling the Leitz Infinity CMM to perform non-contact form measurement on the PACMAN reference wire to permit its axis positioning with an uncertainty such that 3σ < 0.5 µm. The novelty emphasised in this thesis is focused on three main contributions. The form measurement uncertainty reduction obtained by using a chromatic confocal sensor for non-contact measurement on a wire surface is the first contribution. A mathematical model describing the behaviour of air pads over a through hole in the bearing surface composes the second contribution to knowledge. The demonstrated ability to obtain a micrometric form deviation on a rotary symmetric complex shape generated by additive manufacturing of titanium is the third contribution","abstract_html":"In the field of high energy physics, the characterisation and positioning in space of a wire with a diameter of 0.1 mm is one of the steps to increase the precision of future accelerators’ pre-alignment. This reference wire is measured within a high accuracy Coordinate Measuring Machine (CMM) to reduce its positioning uncertainty. No sensor could measure the wire position within the targeted uncertainty. This thesis addresses this issue by proposing a design for the Shape Evaluating Sensor: High Accuracy &amp; Touchless (SESHAT). The SESHAT operates a chromatic confocal sensor. The sensor is fixed to a rotor with a radial opening to allow the stretched wire to traverse it. This rotor is guided by a high precision air bearing controlled by a piezoelectric actuator. The mass limit for the stylus system of the CMM entailed the additive manufacturing of a hollow rotor. The high likelihood of particles on the wire surface involved a form deviation capability for the SESHAT, to reduce position measurement uncertainty. The aim of the research was to design a sensor enabling the Leitz Infinity CMM to perform non-contact form measurement on the PACMAN reference wire to permit its axis positioning with an uncertainty such that 3σ &lt; 0.5 µm. The novelty emphasised in this thesis is focused on three main contributions. The form measurement uncertainty reduction obtained by using a chromatic confocal sensor for non-contact measurement on a wire surface is the first contribution. A mathematical model describing the behaviour of air pads over a through hole in the bearing surface composes the second contribution to knowledge. The demonstrated ability to obtain a micrometric form deviation on a rotary symmetric complex shape generated by additive manufacturing of titanium is the third contribution","abstract_has_math":false,"creators":["Sanz, Claude"],"institution":"Cranfield University","degree_name":null,"degree_level":null,"degree_discipline":null,"degree_department":null,"school":null,"contributors":[],"advisors":["Giusca, Claudiu","Morantz, Paul","Shore, Paul"],"committee_chairs":[],"committee_members":[],"year":2018,"date_issued":"2018-02","date_published":"2018-02","updated_at":"2026-11-26T14:24:43Z","subjects":["Metrology tool","High Precision Mechanics","Reference","Alignment","Particle Accelerator","Compact Linear Collider CLIC","Coordinate Measuring Machine","European Centre for Nuclear Research CERN"],"languages":["en"],"rights":["© Cranfield University, 2018. All rights reserved. No part of this publication may be reproduced without the written permission of the copyright holder."],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"https://dspace.lib.cranfield.ac.uk/handle/1826/22865","outbound_label":"Repository record","outbound_source":"dc:identifier.uri","record_url":"https://dspace.lib.cranfield.ac.uk/handle/1826/22865","record_label":"Repository record","record_kind":"record","record_source":"dc:identifier.uri","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Acranfield%3Aoai%3Adspace.lib.cranfield.ac.uk%3A1826%2F22865","prefix":"oai_dc"},"source_record":{"url":"https://dspace.lib.cranfield.ac.uk/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Adspace.lib.cranfield.ac.uk%3A1826%2F22865","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Giusca, Claudiu","Morantz, Paul","Shore, Paul"]},{"key":"dc:creator","label":"Author","values":["Sanz, Claude"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2024-08-29T11:00:05Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2024-08-29T11:00:05Z"]},{"key":"dc:date.firstopenaccess","label":"Dc Date Firstopenaccess","values":["2024-08-29"]},{"key":"dc:date.issued","label":"Date","values":["2018-02"]},{"key":"dc:publisher","label":"Institution","values":["Cranfield University"]},{"key":"dc:publisher.department","label":"Dc Publisher Department","values":["SATM"]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]},{"key":"dc:type.qualificationlevel","label":"Dc Type Qualificationlevel","values":["Doctoral"]},{"key":"dc:type.qualificationname","label":"Dc Type Qualificationname","values":["PhD"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Metrology tool","High Precision Mechanics","Reference","Alignment","Particle Accelerator","Compact Linear Collider CLIC","Coordinate Measuring Machine","European Centre for Nuclear Research CERN"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["en"]},{"key":"dc:rights","label":"Dc Rights","values":["© Cranfield University, 2018. All rights reserved. No part of this publication may be reproduced without the written permission of the copyright holder."]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://dspace.lib.cranfield.ac.uk/handle/1826/22865"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description","label":"Description","values":["Shore, Paul - Associate Supervisor"]},{"key":"dc:description.abstract","label":"Abstract","values":["In the field of high energy physics, the characterisation and positioning in space of a wire with a diameter of 0.1 mm is one of the steps to increase the precision of future accelerators’ pre-alignment. This reference wire is measured within a high accuracy Coordinate Measuring Machine (CMM) to reduce its positioning uncertainty. No sensor could measure the wire position within the targeted uncertainty. This thesis addresses this issue by proposing a design for the Shape Evaluating Sensor: High Accuracy & Touchless (SESHAT). The SESHAT operates a chromatic confocal sensor. The sensor is fixed to a rotor with a radial opening to allow the stretched wire to traverse it. This rotor is guided by a high precision air bearing controlled by a piezoelectric actuator. The mass limit for the stylus system of the CMM entailed the additive manufacturing of a hollow rotor. The high likelihood of particles on the wire surface involved a form deviation capability for the SESHAT, to reduce position measurement uncertainty. The aim of the research was to design a sensor enabling the Leitz Infinity CMM to perform non-contact form measurement on the PACMAN reference wire to permit its axis positioning with an uncertainty such that 3σ < 0.5 µm. The novelty emphasised in this thesis is focused on three main contributions. The form measurement uncertainty reduction obtained by using a chromatic confocal sensor for non-contact measurement on a wire surface is the first contribution. A mathematical model describing the behaviour of air pads over a through hole in the bearing surface composes the second contribution to knowledge. The demonstrated ability to obtain a micrometric form deviation on a rotary symmetric complex shape generated by additive manufacturing of titanium is the third contribution"]},{"key":"dc:description.coursename","label":"Dc Description Coursename","values":["PhD in Manufacturing"]},{"key":"dc:title","label":"Title","values":["Rotary mount design for a chromatic confocal sensor, involving additive manufacturing and an opened air bearing"]},{"key":"others:access_status","label":"Others Access Status","values":["open.access"]}]}],"canonical_facts":{"dc:contributor.advisor":["Giusca, Claudiu","Morantz, Paul","Shore, Paul"],"dc:creator":["Sanz, Claude"],"dc:date.accessioned":["2024-08-29T11:00:05Z"],"dc:date.available":["2024-08-29T11:00:05Z"],"dc:date.firstopenaccess":["2024-08-29"],"dc:date.issued":["2018-02"],"dc:description":["Shore, Paul - Associate Supervisor"],"dc:description.abstract":["In the field of high energy physics, the characterisation and positioning in space of a wire with a diameter of 0.1 mm is one of the steps to increase the precision of future accelerators’ pre-alignment. This reference wire is measured within a high accuracy Coordinate Measuring Machine (CMM) to reduce its positioning uncertainty. No sensor could measure the wire position within the targeted uncertainty. This thesis addresses this issue by proposing a design for the Shape Evaluating Sensor: High Accuracy & Touchless (SESHAT). The SESHAT operates a chromatic confocal sensor. The sensor is fixed to a rotor with a radial opening to allow the stretched wire to traverse it. This rotor is guided by a high precision air bearing controlled by a piezoelectric actuator. The mass limit for the stylus system of the CMM entailed the additive manufacturing of a hollow rotor. The high likelihood of particles on the wire surface involved a form deviation capability for the SESHAT, to reduce position measurement uncertainty. The aim of the research was to design a sensor enabling the Leitz Infinity CMM to perform non-contact form measurement on the PACMAN reference wire to permit its axis positioning with an uncertainty such that 3σ < 0.5 µm. The novelty emphasised in this thesis is focused on three main contributions. The form measurement uncertainty reduction obtained by using a chromatic confocal sensor for non-contact measurement on a wire surface is the first contribution. A mathematical model describing the behaviour of air pads over a through hole in the bearing surface composes the second contribution to knowledge. The demonstrated ability to obtain a micrometric form deviation on a rotary symmetric complex shape generated by additive manufacturing of titanium is the third contribution"],"dc:description.coursename":["PhD in Manufacturing"],"dc:identifier.uri":["https://dspace.lib.cranfield.ac.uk/handle/1826/22865"],"dc:language.iso":["en"],"dc:publisher":["Cranfield University"],"dc:publisher.department":["SATM"],"dc:rights":["© Cranfield University, 2018. All rights reserved. No part of this publication may be reproduced without the written permission of the copyright holder."],"dc:subject":["Metrology tool","High Precision Mechanics","Reference","Alignment","Particle Accelerator","Compact Linear Collider CLIC","Coordinate Measuring Machine","European Centre for Nuclear Research CERN"],"dc:title":["Rotary mount design for a chromatic confocal sensor, involving additive manufacturing and an opened air bearing"],"dc:type":["Thesis"],"dc:type.qualificationlevel":["Doctoral"],"dc:type.qualificationname":["PhD"],"others:access_status":["open.access"]},"updated_at":"2026-11-26T14:24:43Z"}