{"id":{"repo_id":"cranfield","oai_identifier":"oai:dspace.lib.cranfield.ac.uk:1826/24119"},"canonical_url":"https://search.ndltd.org/etd/cranfield/oai:dspace.lib.cranfield.ac.uk:1826/24119","repository":{"repo_id":"cranfield","name":"Cranfield University","base_url":"https://dspace.lib.cranfield.ac.uk/server/oai/request"},"display":{"title":"Design of ultra-precision piston/cylinders for directly calibrated hydraulic amplification","abstract":"Force calibrations in the Mega Newton range are not currently providing the accuracy required by industry. This work addresses a hydraulic force standards, which perform such calibrations, which work b amplifying the force produced on a small piston/cylinder assembly (PCA) by connecting it hydraulically to a larger PCA. The force standards are currently calibrated using a transducer to the more accurate deadweight machines, but not without a resulting uncertainty of 0.01 % - 0.02 % imparted by the transducer performing the calibration. Because of this, the potential for evaluating uncertainties within the machine from first principles and using it as a primary machine, with traceability maintained to the weights is evaluated. First of all the potential for the resulting reduction in uncertainties is evaluated analytically, then FEA/CFD work is carried out to produce analytical formulae which allow for the design of a directly calibrated system. The analysis is carried out for both the rotational and non-rotational variants of PCA. Finally, the design of a primary hydraulic standard is carried out using FEA/CFD.","abstract_html":"Force calibrations in the Mega Newton range are not currently providing the accuracy required by industry. This work addresses a hydraulic force standards, which perform such calibrations, which work b amplifying the force produced on a small piston/cylinder assembly (PCA) by connecting it hydraulically to a larger PCA. The force standards are currently calibrated using a transducer to the more accurate deadweight machines, but not without a resulting uncertainty of 0.01 % - 0.02 % imparted by the transducer performing the calibration. Because of this, the potential for evaluating uncertainties within the machine from first principles and using it as a primary machine, with traceability maintained to the weights is evaluated. First of all the potential for the resulting reduction in uncertainties is evaluated analytically, then FEA/CFD work is carried out to produce analytical formulae which allow for the design of a directly calibrated system. The analysis is carried out for both the rotational and non-rotational variants of PCA. Finally, the design of a primary hydraulic standard is carried out using FEA/CFD.","abstract_has_math":false,"creators":["Dennis, Ashley Grant"],"institution":"Cranfield University","degree_name":null,"degree_level":null,"degree_discipline":null,"degree_department":null,"school":null,"contributors":[],"advisors":["Giusca, Claudiu","Goel, Saurav"],"committee_chairs":[],"committee_members":[],"year":2022,"date_issued":"2022-01","date_published":"2022-01","updated_at":"2026-11-26T14:24:47Z","subjects":["Force Metrology","Mega Newton","Pressure Balance","Direct Calibration","Primary Standard","FEA","CFD"],"languages":["en"],"rights":["© Cranfield University, 2022. All rights reserved. No part of this publication may be reproduced without the written permission of the copyright holder."],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"https://dspace.lib.cranfield.ac.uk/handle/1826/24119","outbound_label":"Repository record","outbound_source":"dc:identifier.uri","record_url":"https://dspace.lib.cranfield.ac.uk/handle/1826/24119","record_label":"Repository record","record_kind":"record","record_source":"dc:identifier.uri","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Acranfield%3Aoai%3Adspace.lib.cranfield.ac.uk%3A1826%2F24119","prefix":"oai_dc"},"source_record":{"url":"https://dspace.lib.cranfield.ac.uk/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Adspace.lib.cranfield.ac.uk%3A1826%2F24119","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Giusca, Claudiu","Goel, Saurav"]},{"key":"dc:creator","label":"Author","values":["Dennis, Ashley Grant"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2025-07-01T10:10:31Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2025-07-01T10:10:31Z"]},{"key":"dc:date.firstopenaccess","label":"Dc Date Firstopenaccess","values":["2025-07-01"]},{"key":"dc:date.issued","label":"Date","values":["2022-01"]},{"key":"dc:publisher","label":"Institution","values":["Cranfield University"]},{"key":"dc:publisher.department","label":"Dc Publisher Department","values":["SATM"]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]},{"key":"dc:type.qualificationlevel","label":"Dc Type Qualificationlevel","values":["Doctoral"]},{"key":"dc:type.qualificationname","label":"Dc Type Qualificationname","values":["PhD"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Force Metrology","Mega Newton","Pressure Balance","Direct Calibration","Primary Standard","FEA","CFD"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["en"]},{"key":"dc:rights","label":"Dc Rights","values":["© Cranfield University, 2022. All rights reserved. No part of this publication may be reproduced without the written permission of the copyright holder."]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://dspace.lib.cranfield.ac.uk/handle/1826/24119"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["Force calibrations in the Mega Newton range are not currently providing the accuracy required by industry. This work addresses a hydraulic force standards, which perform such calibrations, which work b amplifying the force produced on a small piston/cylinder assembly (PCA) by connecting it hydraulically to a larger PCA. The force standards are currently calibrated using a transducer to the more accurate deadweight machines, but not without a resulting uncertainty of 0.01 % - 0.02 % imparted by the transducer performing the calibration. Because of this, the potential for evaluating uncertainties within the machine from first principles and using it as a primary machine, with traceability maintained to the weights is evaluated. First of all the potential for the resulting reduction in uncertainties is evaluated analytically, then FEA/CFD work is carried out to produce analytical formulae which allow for the design of a directly calibrated system. The analysis is carried out for both the rotational and non-rotational variants of PCA. Finally, the design of a primary hydraulic standard is carried out using FEA/CFD."]},{"key":"dc:description.coursename","label":"Dc Description Coursename","values":["PhD in Manufacturing"]},{"key":"dc:title","label":"Title","values":["Design of ultra-precision piston/cylinders for directly calibrated hydraulic amplification"]},{"key":"others:access_status","label":"Others Access Status","values":["open.access"]}]}],"canonical_facts":{"dc:contributor.advisor":["Giusca, Claudiu","Goel, Saurav"],"dc:creator":["Dennis, Ashley Grant"],"dc:date.accessioned":["2025-07-01T10:10:31Z"],"dc:date.available":["2025-07-01T10:10:31Z"],"dc:date.firstopenaccess":["2025-07-01"],"dc:date.issued":["2022-01"],"dc:description.abstract":["Force calibrations in the Mega Newton range are not currently providing the accuracy required by industry. This work addresses a hydraulic force standards, which perform such calibrations, which work b amplifying the force produced on a small piston/cylinder assembly (PCA) by connecting it hydraulically to a larger PCA. The force standards are currently calibrated using a transducer to the more accurate deadweight machines, but not without a resulting uncertainty of 0.01 % - 0.02 % imparted by the transducer performing the calibration. Because of this, the potential for evaluating uncertainties within the machine from first principles and using it as a primary machine, with traceability maintained to the weights is evaluated. First of all the potential for the resulting reduction in uncertainties is evaluated analytically, then FEA/CFD work is carried out to produce analytical formulae which allow for the design of a directly calibrated system. The analysis is carried out for both the rotational and non-rotational variants of PCA. Finally, the design of a primary hydraulic standard is carried out using FEA/CFD."],"dc:description.coursename":["PhD in Manufacturing"],"dc:identifier.uri":["https://dspace.lib.cranfield.ac.uk/handle/1826/24119"],"dc:language.iso":["en"],"dc:publisher":["Cranfield University"],"dc:publisher.department":["SATM"],"dc:rights":["© Cranfield University, 2022. All rights reserved. No part of this publication may be reproduced without the written permission of the copyright holder."],"dc:subject":["Force Metrology","Mega Newton","Pressure Balance","Direct Calibration","Primary Standard","FEA","CFD"],"dc:title":["Design of ultra-precision piston/cylinders for directly calibrated hydraulic amplification"],"dc:type":["Thesis"],"dc:type.qualificationlevel":["Doctoral"],"dc:type.qualificationname":["PhD"],"others:access_status":["open.access"]},"updated_at":"2026-11-26T14:24:47Z"}