{"id":{"repo_id":"cranfield","oai_identifier":"oai:dspace.lib.cranfield.ac.uk:1826/25752"},"canonical_url":"https://search.ndltd.org/etd/cranfield/oai:dspace.lib.cranfield.ac.uk:1826/25752","repository":{"repo_id":"cranfield","name":"Cranfield University","base_url":"https://dspace.lib.cranfield.ac.uk/server/oai/request"},"display":{"title":"Transforming Sound into Diagnosis - Leveraging Transformer-Based Models for Non-Invasive COVID-19 Detection Using Cough Analysis","abstract":"The COVID-19 pandemic highlighted the urgent need for non-invasive, rapid, and scalable screening tools to alleviate pressure on healthcare systems. This thesis investigates the efficacy of leveraging acoustic information from cough sounds for COVID-19 detection, focusing on the application of modern deep learning architectures. The rationale is that respiratory infections alter the acoustic properties of coughs, creating patterns that can be identified by advanced AI models. This research employed the large-scale, crowdsourced CoughVID dataset. A rigorous data preprocessing pipeline involving normalization, segmentation, and verification was implemented to create curated subsets for analysis. The methodology centered on a systematic, comparative evaluation of three model families: a baseline Convolutional Neural Network (CNN), various Transformer-based architectures (ViT, DeiT, BEiT), and hybrid CNN-Transformer models (ConvNeXt, Swin). Models were trained on Short-Time Fourier Transform (STFT) spectrograms, which were identified as the optimal feature representation in a preliminary experiment. Performance was assessed using accuracy, precision, F1-score, AUC, and a primary focus on recall to reflect clinical screening priorities. The findings demonstrate that hybrid and Transformer-based models, particularly ConvNeXt V2 and the self-supervised BEiT, significantly outperform the baseline CNN. These architectures achieved high recall and robust performance, proving effective at identifying positive cases. The study also revealed that curated data quality and class balance are more critical for model success than sheer data volume. Furthermore, analysis showed performance disparities across demographic subgroups, underscoring the necessity of fairness-aware model development. In conclusion, this thesis establishes that Transformer and hybrid architectures can serve as a powerful foundation for non-invasive respiratory diagnostic tools. By combining advanced models with optimal feature representation and carefully curated data, it is possible to develop reliable and scalable screening systems. The research provides an evidence-based framework for future development, emphasizing robust validation and ethical considerations for clinical deployment.","abstract_html":"The COVID-19 pandemic highlighted the urgent need for non-invasive, rapid, and scalable screening tools to alleviate pressure on healthcare systems. This thesis investigates the efficacy of leveraging acoustic information from cough sounds for COVID-19 detection, focusing on the application of modern deep learning architectures. The rationale is that respiratory infections alter the acoustic properties of coughs, creating patterns that can be identified by advanced AI models. This research employed the large-scale, crowdsourced CoughVID dataset. A rigorous data preprocessing pipeline involving normalization, segmentation, and verification was implemented to create curated subsets for analysis. The methodology centered on a systematic, comparative evaluation of three model families: a baseline Convolutional Neural Network (CNN), various Transformer-based architectures (ViT, DeiT, BEiT), and hybrid CNN-Transformer models (ConvNeXt, Swin). Models were trained on Short-Time Fourier Transform (STFT) spectrograms, which were identified as the optimal feature representation in a preliminary experiment. Performance was assessed using accuracy, precision, F1-score, AUC, and a primary focus on recall to reflect clinical screening priorities. The findings demonstrate that hybrid and Transformer-based models, particularly ConvNeXt V2 and the self-supervised BEiT, significantly outperform the baseline CNN. These architectures achieved high recall and robust performance, proving effective at identifying positive cases. The study also revealed that curated data quality and class balance are more critical for model success than sheer data volume. Furthermore, analysis showed performance disparities across demographic subgroups, underscoring the necessity of fairness-aware model development. In conclusion, this thesis establishes that Transformer and hybrid architectures can serve as a powerful foundation for non-invasive respiratory diagnostic tools. By combining advanced models with optimal feature representation and carefully curated data, it is possible to develop reliable and scalable screening systems. The research provides an evidence-based framework for future development, emphasizing robust validation and ethical considerations for clinical deployment.","abstract_has_math":false,"creators":["Pourghorban, Amirsalar"],"institution":"Cranfield University","degree_name":null,"degree_level":null,"degree_discipline":null,"degree_department":null,"school":null,"contributors":[],"advisors":["Samie, Mohammad"],"committee_chairs":[],"committee_members":[],"year":2025,"date_issued":"2025-08","date_published":"2025-08","updated_at":"2026-11-26T14:27:44Z","subjects":["Respiratory audio analysis","Cough-based diagnostics","Feature extraction methods","Deep learning","Vision Transformers","Hybrid CNN–Transformer architectures","Spectrogram classification","Non-invasive screening"],"languages":["en"],"rights":[],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"https://dspace.lib.cranfield.ac.uk/handle/1826/25752","outbound_label":"Repository record","outbound_source":"dc:identifier.uri","record_url":"https://dspace.lib.cranfield.ac.uk/handle/1826/25752","record_label":"Repository record","record_kind":"record","record_source":"dc:identifier.uri","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Acranfield%3Aoai%3Adspace.lib.cranfield.ac.uk%3A1826%2F25752","prefix":"oai_dc"},"source_record":{"url":"https://dspace.lib.cranfield.ac.uk/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Adspace.lib.cranfield.ac.uk%3A1826%2F25752","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Samie, Mohammad"]},{"key":"dc:creator","label":"Author","values":["Pourghorban, Amirsalar"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2026-10-30T09:26:53Z"]},{"key":"dc:date.firstopenaccess","label":"Dc Date Firstopenaccess","values":["2026-10-30"]},{"key":"dc:date.issued","label":"Date","values":["2025-08"]},{"key":"dc:publisher","label":"Institution","values":["Cranfield University"]},{"key":"dc:publisher.department","label":"Dc Publisher Department","values":["AA"]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]},{"key":"dc:type.qualificationlevel","label":"Dc Type Qualificationlevel","values":["Doctoral"]},{"key":"dc:type.qualificationname","label":"Dc Type Qualificationname","values":["PhD"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Respiratory audio analysis","Cough-based diagnostics","Feature extraction methods","Deep learning","Vision Transformers","Hybrid CNN–Transformer architectures","Spectrogram classification","Non-invasive screening"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["en"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://dspace.lib.cranfield.ac.uk/handle/1826/25752"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["The COVID-19 pandemic highlighted the urgent need for non-invasive, rapid, and scalable screening tools to alleviate pressure on healthcare systems. This thesis investigates the efficacy of leveraging acoustic information from cough sounds for COVID-19 detection, focusing on the application of modern deep learning architectures. The rationale is that respiratory infections alter the acoustic properties of coughs, creating patterns that can be identified by advanced AI models. This research employed the large-scale, crowdsourced CoughVID dataset. A rigorous data preprocessing pipeline involving normalization, segmentation, and verification was implemented to create curated subsets for analysis. The methodology centered on a systematic, comparative evaluation of three model families: a baseline Convolutional Neural Network (CNN), various Transformer-based architectures (ViT, DeiT, BEiT), and hybrid CNN-Transformer models (ConvNeXt, Swin). Models were trained on Short-Time Fourier Transform (STFT) spectrograms, which were identified as the optimal feature representation in a preliminary experiment. Performance was assessed using accuracy, precision, F1-score, AUC, and a primary focus on recall to reflect clinical screening priorities. The findings demonstrate that hybrid and Transformer-based models, particularly ConvNeXt V2 and the self-supervised BEiT, significantly outperform the baseline CNN. These architectures achieved high recall and robust performance, proving effective at identifying positive cases. The study also revealed that curated data quality and class balance are more critical for model success than sheer data volume. Furthermore, analysis showed performance disparities across demographic subgroups, underscoring the necessity of fairness-aware model development. In conclusion, this thesis establishes that Transformer and hybrid architectures can serve as a powerful foundation for non-invasive respiratory diagnostic tools. By combining advanced models with optimal feature representation and carefully curated data, it is possible to develop reliable and scalable screening systems. The research provides an evidence-based framework for future development, emphasizing robust validation and ethical considerations for clinical deployment."]},{"key":"dc:description.coursename","label":"Dc Description Coursename","values":["PhD in Transport Systems"]},{"key":"dc:title","label":"Title","values":["Transforming Sound into Diagnosis - Leveraging Transformer-Based Models for Non-Invasive COVID-19 Detection Using Cough Analysis"]},{"key":"others:access_status","label":"Others Access Status","values":["open.access"]}]}],"canonical_facts":{"dc:contributor.advisor":["Samie, Mohammad"],"dc:creator":["Pourghorban, Amirsalar"],"dc:date.accessioned":["2026-10-30T09:26:53Z"],"dc:date.firstopenaccess":["2026-10-30"],"dc:date.issued":["2025-08"],"dc:description.abstract":["The COVID-19 pandemic highlighted the urgent need for non-invasive, rapid, and scalable screening tools to alleviate pressure on healthcare systems. This thesis investigates the efficacy of leveraging acoustic information from cough sounds for COVID-19 detection, focusing on the application of modern deep learning architectures. The rationale is that respiratory infections alter the acoustic properties of coughs, creating patterns that can be identified by advanced AI models. This research employed the large-scale, crowdsourced CoughVID dataset. A rigorous data preprocessing pipeline involving normalization, segmentation, and verification was implemented to create curated subsets for analysis. The methodology centered on a systematic, comparative evaluation of three model families: a baseline Convolutional Neural Network (CNN), various Transformer-based architectures (ViT, DeiT, BEiT), and hybrid CNN-Transformer models (ConvNeXt, Swin). Models were trained on Short-Time Fourier Transform (STFT) spectrograms, which were identified as the optimal feature representation in a preliminary experiment. Performance was assessed using accuracy, precision, F1-score, AUC, and a primary focus on recall to reflect clinical screening priorities. The findings demonstrate that hybrid and Transformer-based models, particularly ConvNeXt V2 and the self-supervised BEiT, significantly outperform the baseline CNN. These architectures achieved high recall and robust performance, proving effective at identifying positive cases. The study also revealed that curated data quality and class balance are more critical for model success than sheer data volume. Furthermore, analysis showed performance disparities across demographic subgroups, underscoring the necessity of fairness-aware model development. In conclusion, this thesis establishes that Transformer and hybrid architectures can serve as a powerful foundation for non-invasive respiratory diagnostic tools. By combining advanced models with optimal feature representation and carefully curated data, it is possible to develop reliable and scalable screening systems. The research provides an evidence-based framework for future development, emphasizing robust validation and ethical considerations for clinical deployment."],"dc:description.coursename":["PhD in Transport Systems"],"dc:identifier.uri":["https://dspace.lib.cranfield.ac.uk/handle/1826/25752"],"dc:language.iso":["en"],"dc:publisher":["Cranfield University"],"dc:publisher.department":["AA"],"dc:subject":["Respiratory audio analysis","Cough-based diagnostics","Feature extraction methods","Deep learning","Vision Transformers","Hybrid CNN–Transformer architectures","Spectrogram classification","Non-invasive screening"],"dc:title":["Transforming Sound into Diagnosis - Leveraging Transformer-Based Models for Non-Invasive COVID-19 Detection Using Cough Analysis"],"dc:type":["Thesis"],"dc:type.qualificationlevel":["Doctoral"],"dc:type.qualificationname":["PhD"],"others:access_status":["open.access"]},"updated_at":"2026-11-26T14:27:44Z"}