{"id":{"repo_id":"cranfield","oai_identifier":"oai:dspace.lib.cranfield.ac.uk:1826/25905"},"canonical_url":"https://search.ndltd.org/etd/cranfield/oai:dspace.lib.cranfield.ac.uk:1826/25905","repository":{"repo_id":"cranfield","name":"Cranfield University","base_url":"https://dspace.lib.cranfield.ac.uk/server/oai/request"},"display":{"title":"Will it Stick? A feasibility study on fan-powered cars to drive upside down","abstract":"This study investigates the feasibility of sustaining a road vehicle in an inverted orientation using a fan-driven underfloor suction system. A modified DrivAer fastback model with restrictor walls and twin fan apertures was analysed under stationary conditions. The simulations were performed in ANSYS Fluent by solving the steady incompressible Reynolds-Averaged Navier–Stokes equations with the realizable k-epsilon model and Enhanced Wall Treatment. Verification was conducted through a three-grid study, yielding an apparent order of 1.27 and an asymptotic-range indicator of 1.01; discretisation error was below 1% on the fine mesh and about 3.7% on the medium mesh. Two parametric campaigns quantified sensitivity to ride height and skirt height. At a fixed ride height of 20 mm, the system produced 37.94 kN of downforce at a suction level of −21 kPa and a total mass flow rate of 10.85 kg s⁻¹, exceeding the required 34.62 kN adhesion load by 9.6%. Downforce degraded rapidly with increased ride height due to leakage and footprint fragmentation, and taller skirts likewise reduced performance. Mapping the CFD duty point to hardware indicated a per-fan requirement of 4.52 m³ s⁻¹ at 21 kPa, tip speeds near 187 m s⁻¹ for a 0.46–0.48 m impeller, and an electrical input of about 278 kW for two fans. A 120 s inverted adhesion event would consume approximately 9.3 kWh, while a conservative mass model suggested a system addition of about 320 kg. The findings demonstrate that a fan-powered suction system can theoretically generate sufficient adhesion for inverted operation, but the solution is highly ride-height sensitive and power intensive. Future work should incorporate coupled fan maps, unsteady leakage dynamics, and experimental validation to strengthen practical applicability.","abstract_html":"This study investigates the feasibility of sustaining a road vehicle in an inverted orientation using a fan-driven underfloor suction system. A modified DrivAer fastback model with restrictor walls and twin fan apertures was analysed under stationary conditions. The simulations were performed in ANSYS Fluent by solving the steady incompressible Reynolds-Averaged Navier–Stokes equations with the realizable k-epsilon model and Enhanced Wall Treatment. Verification was conducted through a three-grid study, yielding an apparent order of 1.27 and an asymptotic-range indicator of 1.01; discretisation error was below 1% on the fine mesh and about 3.7% on the medium mesh. Two parametric campaigns quantified sensitivity to ride height and skirt height. At a fixed ride height of 20 mm, the system produced 37.94 kN of downforce at a suction level of −21 kPa and a total mass flow rate of 10.85 kg s⁻¹, exceeding the required 34.62 kN adhesion load by 9.6%. Downforce degraded rapidly with increased ride height due to leakage and footprint fragmentation, and taller skirts likewise reduced performance. Mapping the CFD duty point to hardware indicated a per-fan requirement of 4.52 m³ s⁻¹ at 21 kPa, tip speeds near 187 m s⁻¹ for a 0.46–0.48 m impeller, and an electrical input of about 278 kW for two fans. A 120 s inverted adhesion event would consume approximately 9.3 kWh, while a conservative mass model suggested a system addition of about 320 kg. The findings demonstrate that a fan-powered suction system can theoretically generate sufficient adhesion for inverted operation, but the solution is highly ride-height sensitive and power intensive. Future work should incorporate coupled fan maps, unsteady leakage dynamics, and experimental validation to strengthen practical applicability.","abstract_has_math":false,"creators":["Dhage, Soham"],"institution":"Cranfield University","degree_name":null,"degree_level":null,"degree_discipline":null,"degree_department":null,"school":null,"contributors":[],"advisors":["Teschner, Tom-Robin"],"committee_chairs":[],"committee_members":[],"year":2025,"date_issued":"2025-08","date_published":"2025-08","updated_at":"2026-11-28T14:12:29Z","subjects":["Computational fluid dynamics","Fan car","Ground effect","Underfloor suction","DrivAer","Inverted driving","Vehicle aerodynamics","RANS"],"languages":["en"],"rights":[],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"https://dspace.lib.cranfield.ac.uk/handle/1826/25905","outbound_label":"Repository record","outbound_source":"dc:identifier.uri","record_url":"https://dspace.lib.cranfield.ac.uk/handle/1826/25905","record_label":"Repository record","record_kind":"record","record_source":"dc:identifier.uri","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Acranfield%3Aoai%3Adspace.lib.cranfield.ac.uk%3A1826%2F25905","prefix":"oai_dc"},"source_record":{"url":"https://dspace.lib.cranfield.ac.uk/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Adspace.lib.cranfield.ac.uk%3A1826%2F25905","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Teschner, Tom-Robin"]},{"key":"dc:creator","label":"Author","values":["Dhage, Soham"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2026-11-27T14:27:25Z"]},{"key":"dc:date.issued","label":"Date","values":["2025-08"]},{"key":"dc:publisher","label":"Institution","values":["Cranfield University"]},{"key":"dc:publisher.department","label":"Dc Publisher Department","values":["AI, Robotics and Space"]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]},{"key":"dc:type.qualificationlevel","label":"Dc Type Qualificationlevel","values":["Masters"]},{"key":"dc:type.qualificationname","label":"Dc Type Qualificationname","values":["MSc"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Computational fluid dynamics","Fan car","Ground effect","Underfloor suction","DrivAer","Inverted driving","Vehicle aerodynamics","RANS"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["en"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://dspace.lib.cranfield.ac.uk/handle/1826/25905"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["This study investigates the feasibility of sustaining a road vehicle in an inverted orientation using a fan-driven underfloor suction system. A modified DrivAer fastback model with restrictor walls and twin fan apertures was analysed under stationary conditions. The simulations were performed in ANSYS Fluent by solving the steady incompressible Reynolds-Averaged Navier–Stokes equations with the realizable k-epsilon model and Enhanced Wall Treatment. Verification was conducted through a three-grid study, yielding an apparent order of 1.27 and an asymptotic-range indicator of 1.01; discretisation error was below 1% on the fine mesh and about 3.7% on the medium mesh. Two parametric campaigns quantified sensitivity to ride height and skirt height. At a fixed ride height of 20 mm, the system produced 37.94 kN of downforce at a suction level of −21 kPa and a total mass flow rate of 10.85 kg s⁻¹, exceeding the required 34.62 kN adhesion load by 9.6%. Downforce degraded rapidly with increased ride height due to leakage and footprint fragmentation, and taller skirts likewise reduced performance. Mapping the CFD duty point to hardware indicated a per-fan requirement of 4.52 m³ s⁻¹ at 21 kPa, tip speeds near 187 m s⁻¹ for a 0.46–0.48 m impeller, and an electrical input of about 278 kW for two fans. A 120 s inverted adhesion event would consume approximately 9.3 kWh, while a conservative mass model suggested a system addition of about 320 kg. The findings demonstrate that a fan-powered suction system can theoretically generate sufficient adhesion for inverted operation, but the solution is highly ride-height sensitive and power intensive. Future work should incorporate coupled fan maps, unsteady leakage dynamics, and experimental validation to strengthen practical applicability."]},{"key":"dc:description.coursename","label":"Dc Description Coursename","values":["MSc in Computational Fluid Dynamics"]},{"key":"dc:title","label":"Title","values":["Will it Stick? A feasibility study on fan-powered cars to drive upside down"]},{"key":"others:access_status","label":"Others Access Status","values":["open.access"]}]}],"canonical_facts":{"dc:contributor.advisor":["Teschner, Tom-Robin"],"dc:creator":["Dhage, Soham"],"dc:date.accessioned":["2026-11-27T14:27:25Z"],"dc:date.issued":["2025-08"],"dc:description.abstract":["This study investigates the feasibility of sustaining a road vehicle in an inverted orientation using a fan-driven underfloor suction system. A modified DrivAer fastback model with restrictor walls and twin fan apertures was analysed under stationary conditions. The simulations were performed in ANSYS Fluent by solving the steady incompressible Reynolds-Averaged Navier–Stokes equations with the realizable k-epsilon model and Enhanced Wall Treatment. Verification was conducted through a three-grid study, yielding an apparent order of 1.27 and an asymptotic-range indicator of 1.01; discretisation error was below 1% on the fine mesh and about 3.7% on the medium mesh. Two parametric campaigns quantified sensitivity to ride height and skirt height. At a fixed ride height of 20 mm, the system produced 37.94 kN of downforce at a suction level of −21 kPa and a total mass flow rate of 10.85 kg s⁻¹, exceeding the required 34.62 kN adhesion load by 9.6%. Downforce degraded rapidly with increased ride height due to leakage and footprint fragmentation, and taller skirts likewise reduced performance. Mapping the CFD duty point to hardware indicated a per-fan requirement of 4.52 m³ s⁻¹ at 21 kPa, tip speeds near 187 m s⁻¹ for a 0.46–0.48 m impeller, and an electrical input of about 278 kW for two fans. A 120 s inverted adhesion event would consume approximately 9.3 kWh, while a conservative mass model suggested a system addition of about 320 kg. The findings demonstrate that a fan-powered suction system can theoretically generate sufficient adhesion for inverted operation, but the solution is highly ride-height sensitive and power intensive. Future work should incorporate coupled fan maps, unsteady leakage dynamics, and experimental validation to strengthen practical applicability."],"dc:description.coursename":["MSc in Computational Fluid Dynamics"],"dc:identifier.uri":["https://dspace.lib.cranfield.ac.uk/handle/1826/25905"],"dc:language.iso":["en"],"dc:publisher":["Cranfield University"],"dc:publisher.department":["AI, Robotics and Space"],"dc:subject":["Computational fluid dynamics","Fan car","Ground effect","Underfloor suction","DrivAer","Inverted driving","Vehicle aerodynamics","RANS"],"dc:title":["Will it Stick? A feasibility study on fan-powered cars to drive upside down"],"dc:type":["Thesis"],"dc:type.qualificationlevel":["Masters"],"dc:type.qualificationname":["MSc"],"others:access_status":["open.access"]},"updated_at":"2026-11-28T14:12:29Z"}