{"id":{"repo_id":"cranfield","oai_identifier":"oai:dspace.lib.cranfield.ac.uk:1826/4023"},"canonical_url":"https://search.ndltd.org/etd/cranfield/oai:dspace.lib.cranfield.ac.uk:1826/4023","repository":{"repo_id":"cranfield","name":"Cranfield University","base_url":"https://dspace.lib.cranfield.ac.uk/server/oai/request"},"display":{"title":"A study on the performance of passively heated solar houses","abstract":"In this paper , analytical techniques are developed for evaluating the performance of passively heated buildings. As most buildings use conservatories to enhance their performance , the direct gain types having attached conservatories are considered in detail. The complexity of the problem is minimized by ensuring all equations are developed from first principles. Auxilliary energy predictions for space heating by the method is in close agreement with monitored data for three occupied houses in Milton Keynes in England.","abstract_html":"In this paper , analytical techniques are developed for evaluating the performance of passively heated buildings. As most buildings use conservatories to enhance their performance , the direct gain types having attached conservatories are considered in detail. The complexity of the problem is minimized by ensuring all equations are developed from first principles. Auxilliary energy predictions for space heating by the method is in close agreement with monitored data for three occupied houses in Milton Keynes in England.","abstract_has_math":false,"creators":["Neba-Fabs, N. E."],"institution":"Cranfield University","degree_name":null,"degree_level":null,"degree_discipline":null,"degree_department":null,"school":null,"contributors":[],"advisors":["Batty, W. J."],"committee_chairs":[],"committee_members":[],"year":1990,"date_issued":"1990-03","date_published":"1990-03","updated_at":"2026-11-26T14:21:42Z","subjects":[],"languages":["en"],"rights":[],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"https://hdl.handle.net/1826/4023","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"https://hdl.handle.net/1826/4023","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Acranfield%3Aoai%3Adspace.lib.cranfield.ac.uk%3A1826%2F4023","prefix":"oai_dc"},"source_record":{"url":"https://dspace.lib.cranfield.ac.uk/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Adspace.lib.cranfield.ac.uk%3A1826%2F4023","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Batty, W. J."]},{"key":"dc:creator","label":"Author","values":["Neba-Fabs, N. E."]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2009-11-30T12:08:05Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2009-11-30T12:08:05Z"]},{"key":"dc:date.issued","label":"Date","values":["1990-03"]},{"key":"dc:publisher","label":"Institution","values":["Cranfield University"]},{"key":"dc:type","label":"Dc Type","values":["Thesis or dissertation"]},{"key":"dc:type.qualificationlevel","label":"Dc Type Qualificationlevel","values":["Doctoral"]},{"key":"dc:type.qualificationname","label":"Dc Type Qualificationname","values":["PhD"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["en"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["http://hdl.handle.net/1826/4023"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["In this paper , analytical techniques are developed for evaluating the performance of passively heated buildings. As most buildings use conservatories to enhance their performance , the direct gain types having attached conservatories are considered in detail. The complexity of the problem is minimized by ensuring all equations are developed from first principles. Auxilliary energy predictions for space heating by the method is in close agreement with monitored data for three occupied houses in Milton Keynes in England."]},{"key":"dc:title","label":"Title","values":["A study on the performance of passively heated solar houses"]},{"key":"others:access_status","label":"Others Access Status","values":["open.access"]}]}],"canonical_facts":{"dc:contributor.advisor":["Batty, W. J."],"dc:creator":["Neba-Fabs, N. E."],"dc:date.accessioned":["2009-11-30T12:08:05Z"],"dc:date.available":["2009-11-30T12:08:05Z"],"dc:date.issued":["1990-03"],"dc:description.abstract":["In this paper , analytical techniques are developed for evaluating the performance of passively heated buildings. As most buildings use conservatories to enhance their performance , the direct gain types having attached conservatories are considered in detail. The complexity of the problem is minimized by ensuring all equations are developed from first principles. Auxilliary energy predictions for space heating by the method is in close agreement with monitored data for three occupied houses in Milton Keynes in England."],"dc:identifier.uri":["http://hdl.handle.net/1826/4023"],"dc:language.iso":["en"],"dc:publisher":["Cranfield University"],"dc:title":["A study on the performance of passively heated solar houses"],"dc:type":["Thesis or dissertation"],"dc:type.qualificationlevel":["Doctoral"],"dc:type.qualificationname":["PhD"],"others:access_status":["open.access"]},"updated_at":"2026-11-26T14:21:42Z"}