{"id":{"repo_id":"cranfield","oai_identifier":"oai:dspace.lib.cranfield.ac.uk:1826/5665"},"canonical_url":"https://search.ndltd.org/etd/cranfield/oai:dspace.lib.cranfield.ac.uk:1826/5665","repository":{"repo_id":"cranfield","name":"Cranfield University","base_url":"https://dspace.lib.cranfield.ac.uk/server/oai/request"},"display":{"title":"Development of sensors for the detection of clinically relevant substances using molecular imprinting","abstract":"This thesis investigates the development of sensing devices based on molecularly imprinted polymers for the detection of clinically relevant analytes. Three analytes were considered, metronidazole, creatinine and propofol. A molecularly imprinted polymer (MIP) was computationally designed for metronidazole and tested using SPE techniques. This polymer was then grafted onto a transducer surface using an immobilised initiator. Amperometric and impedance detection of metronidazole were investigated. The capacitive detection of creatinine was reproduced from the literature (Panasyuk- Delaney et al., 2002) as this approach could be applied to other MIPs to form a universal platform for sensor development. However, the sensors produced using this methodology were difficult to reproduce and attempts to improve them were unsuccessful. A model for capacitive electrodes was developed to explain the obtained results. To address the key challenges found in the aforementioned work, a dual polymerisable monomer was used as a conductive anchor for the amperometric and impedance detection of propofol. The developed amperometric sensors demonstrated very high sensitivity (limit of detection was below 5 µM), although the electrodes lacked in selectivity. In conclusion, this thesis illustrates some of the key areas which need to be considered in the development of MIP-based devices and investigates some innovative solutions to these problems.","abstract_html":"This thesis investigates the development of sensing devices based on molecularly imprinted polymers for the detection of clinically relevant analytes. Three analytes were considered, metronidazole, creatinine and propofol. A molecularly imprinted polymer (MIP) was computationally designed for metronidazole and tested using SPE techniques. This polymer was then grafted onto a transducer surface using an immobilised initiator. Amperometric and impedance detection of metronidazole were investigated. The capacitive detection of creatinine was reproduced from the literature (Panasyuk- Delaney et al., 2002) as this approach could be applied to other MIPs to form a universal platform for sensor development. However, the sensors produced using this methodology were difficult to reproduce and attempts to improve them were unsuccessful. A model for capacitive electrodes was developed to explain the obtained results. To address the key challenges found in the aforementioned work, a dual polymerisable monomer was used as a conductive anchor for the amperometric and impedance detection of propofol. The developed amperometric sensors demonstrated very high sensitivity (limit of detection was below 5 µM), although the electrodes lacked in selectivity. In conclusion, this thesis illustrates some of the key areas which need to be considered in the development of MIP-based devices and investigates some innovative solutions to these problems.","abstract_has_math":false,"creators":["Fowler, Steven A."],"institution":"Cranfield University","degree_name":null,"degree_level":null,"degree_discipline":null,"degree_department":null,"school":null,"contributors":[],"advisors":["Piletsky, Sergey A.","Laitenberger, Peter"],"committee_chairs":[],"committee_members":[],"year":2009,"date_issued":"2009","date_published":"2009","updated_at":"2026-11-26T14:23:43Z","subjects":[],"languages":["en"],"rights":["© Cranfield University, 2009. All rights reserved. No part of this publication may be reproduced without the written permission of the copyright holder."],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"http://dspace.lib.cranfield.ac.uk/handle/1826/5665","outbound_label":"Repository record","outbound_source":"dc:identifier.uri","record_url":"http://dspace.lib.cranfield.ac.uk/handle/1826/5665","record_label":"Repository record","record_kind":"record","record_source":"dc:identifier.uri","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Acranfield%3Aoai%3Adspace.lib.cranfield.ac.uk%3A1826%2F5665","prefix":"oai_dc"},"source_record":{"url":"https://dspace.lib.cranfield.ac.uk/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Adspace.lib.cranfield.ac.uk%3A1826%2F5665","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Piletsky, Sergey A.","Laitenberger, Peter"]},{"key":"dc:creator","label":"Author","values":["Fowler, Steven A."]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2011-07-11T15:16:38Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2011-07-11T15:16:38Z"]},{"key":"dc:date.issued","label":"Date","values":["2009"]},{"key":"dc:publisher","label":"Institution","values":["Cranfield University"]},{"key":"dc:type","label":"Dc Type","values":["Thesis or dissertation"]},{"key":"dc:type.qualificationlevel","label":"Dc Type Qualificationlevel","values":["Doctoral"]},{"key":"dc:type.qualificationname","label":"Dc Type Qualificationname","values":["PhD"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["en"]},{"key":"dc:rights","label":"Dc Rights","values":["© Cranfield University, 2009. All rights reserved. No part of this publication may be reproduced without the written permission of the copyright holder."]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["http://dspace.lib.cranfield.ac.uk/handle/1826/5665"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["This thesis investigates the development of sensing devices based on molecularly imprinted polymers for the detection of clinically relevant analytes. Three analytes were considered, metronidazole, creatinine and propofol. A molecularly imprinted polymer (MIP) was computationally designed for metronidazole and tested using SPE techniques. This polymer was then grafted onto a transducer surface using an immobilised initiator. Amperometric and impedance detection of metronidazole were investigated. The capacitive detection of creatinine was reproduced from the literature (Panasyuk- Delaney et al., 2002) as this approach could be applied to other MIPs to form a universal platform for sensor development. However, the sensors produced using this methodology were difficult to reproduce and attempts to improve them were unsuccessful. A model for capacitive electrodes was developed to explain the obtained results. To address the key challenges found in the aforementioned work, a dual polymerisable monomer was used as a conductive anchor for the amperometric and impedance detection of propofol. The developed amperometric sensors demonstrated very high sensitivity (limit of detection was below 5 µM), although the electrodes lacked in selectivity. In conclusion, this thesis illustrates some of the key areas which need to be considered in the development of MIP-based devices and investigates some innovative solutions to these problems."]},{"key":"dc:title","label":"Title","values":["Development of sensors for the detection of clinically relevant substances using molecular imprinting"]},{"key":"others:access_status","label":"Others Access Status","values":["open.access"]}]}],"canonical_facts":{"dc:contributor.advisor":["Piletsky, Sergey A.","Laitenberger, Peter"],"dc:creator":["Fowler, Steven A."],"dc:date.accessioned":["2011-07-11T15:16:38Z"],"dc:date.available":["2011-07-11T15:16:38Z"],"dc:date.issued":["2009"],"dc:description.abstract":["This thesis investigates the development of sensing devices based on molecularly imprinted polymers for the detection of clinically relevant analytes. Three analytes were considered, metronidazole, creatinine and propofol. A molecularly imprinted polymer (MIP) was computationally designed for metronidazole and tested using SPE techniques. This polymer was then grafted onto a transducer surface using an immobilised initiator. Amperometric and impedance detection of metronidazole were investigated. The capacitive detection of creatinine was reproduced from the literature (Panasyuk- Delaney et al., 2002) as this approach could be applied to other MIPs to form a universal platform for sensor development. However, the sensors produced using this methodology were difficult to reproduce and attempts to improve them were unsuccessful. A model for capacitive electrodes was developed to explain the obtained results. To address the key challenges found in the aforementioned work, a dual polymerisable monomer was used as a conductive anchor for the amperometric and impedance detection of propofol. The developed amperometric sensors demonstrated very high sensitivity (limit of detection was below 5 µM), although the electrodes lacked in selectivity. In conclusion, this thesis illustrates some of the key areas which need to be considered in the development of MIP-based devices and investigates some innovative solutions to these problems."],"dc:identifier.uri":["http://dspace.lib.cranfield.ac.uk/handle/1826/5665"],"dc:language.iso":["en"],"dc:publisher":["Cranfield University"],"dc:rights":["© Cranfield University, 2009. All rights reserved. No part of this publication may be reproduced without the written permission of the copyright holder."],"dc:title":["Development of sensors for the detection of clinically relevant substances using molecular imprinting"],"dc:type":["Thesis or dissertation"],"dc:type.qualificationlevel":["Doctoral"],"dc:type.qualificationname":["PhD"],"others:access_status":["open.access"]},"updated_at":"2026-11-26T14:23:43Z"}