{"id":{"repo_id":"csusb","oai_identifier":"oai:scholarworks.lib.csusb.edu:etd-project-3801"},"canonical_url":"https://search.ndltd.org/etd/csusb/oai:scholarworks.lib.csusb.edu:etd-project-3801","repository":{"repo_id":"csusb","name":"CSUniversity San Bernardino","base_url":"https://scholarworks.lib.csusb.edu/do/oai/"},"display":{"title":"Optimization of a sequential alignment verification and positioning system (SAVPS) for proton radiosurgery","abstract":"Functional proton-beam stereotactic radiosurgery requires sub-millimeter alignment accuracy. A patient tracking system called Sequential Alignment and Position Verification System (SAVPS) is under development at Loma Linda University Medical Center. An optical positioning system (OPS), manufactured by Vicon Peak, has been chosen to verify the correct alignment of the target with the proton beam axis. The main objective of this thesis is to optimize an existing version of SAVPS by conducting error analysis. An image processing algorithm was developed and applied to estimate the error introduced by the Patient Positioning System (PPS) in order to derive the true error of the SAVPS.","abstract_html":"Functional proton-beam stereotactic radiosurgery requires sub-millimeter alignment accuracy. A patient tracking system called Sequential Alignment and Position Verification System (SAVPS) is under development at Loma Linda University Medical Center. An optical positioning system (OPS), manufactured by Vicon Peak, has been chosen to verify the correct alignment of the target with the proton beam axis. The main objective of this thesis is to optimize an existing version of SAVPS by conducting error analysis. An image processing algorithm was developed and applied to estimate the error introduced by the Patient Positioning System (PPS) in order to derive the true error of the SAVPS.","abstract_has_math":false,"creators":["Neupane, Mahesh Raj"],"institution":null,"degree_name":"Master of Science in Computer Science","degree_level":"Thesis","degree_discipline":"School of Computer Science and Engineering","degree_department":null,"school":null,"contributors":[],"advisors":[],"committee_chairs":[],"committee_members":[],"year":null,"date_issued":"","date_published":null,"updated_at":"2026-11-19T08:06:39Z","subjects":["Radiosurgery","Radiosurgery Quality control","Stereoencephalotomy","Stereoencephalotomy Quality control","Proton beams Therapeutic use","Protons Therapeutic use","Radiosurgery Instrumentation","Radiation dosimetry","Brain Tumors Radiotherapy","Radioisotope brachytherapy","Stereoencephalotomy.","Software Engineering"],"languages":[],"rights":[],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"https://scholarworks.lib.csusb.edu/etd-project/2784","outbound_label":"Repository record","outbound_source":"dc:identifier","record_url":"https://scholarworks.lib.csusb.edu/etd-project/2784","record_label":"Repository record","record_kind":"record","record_source":"dc:identifier","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://scholarworks.lib.csusb.edu/do/oai/?verb=GetRecord&metadataPrefix=oai_etdms&identifier=oai%3Ascholarworks.lib.csusb.edu%3Aetd-project-3801","prefix":"oai_etdms"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:creator","label":"Author","values":["Neupane, Mahesh Raj"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.created","label":"Dc Date Created","values":["2005-01-01T08:00:00Z"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["School of Computer Science and Engineering"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Thesis"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Science in Computer Science"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Radiosurgery","Radiosurgery Quality control","Stereoencephalotomy","Stereoencephalotomy Quality control","Proton beams Therapeutic use","Protons Therapeutic use","Radiosurgery Instrumentation","Radiation dosimetry","Brain Tumors Radiotherapy","Radioisotope brachytherapy","Stereoencephalotomy.","Software Engineering"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["https://scholarworks.lib.csusb.edu/etd-project/2784"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["Functional proton-beam stereotactic radiosurgery requires sub-millimeter alignment accuracy. A patient tracking system called Sequential Alignment and Position Verification System (SAVPS) is under development at Loma Linda University Medical Center. An optical positioning system (OPS), manufactured by Vicon Peak, has been chosen to verify the correct alignment of the target with the proton beam axis. The main objective of this thesis is to optimize an existing version of SAVPS by conducting error analysis. An image processing algorithm was developed and applied to estimate the error introduced by the Patient Positioning System (PPS) in order to derive the true error of the SAVPS."]},{"key":"dc:title","label":"Title","values":["Optimization of a sequential alignment verification and positioning system (SAVPS) for proton radiosurgery"]}]}],"canonical_facts":{"dc:creator":["Neupane, Mahesh Raj"],"dc:date.created":["2005-01-01T08:00:00Z"],"dc:description.abstract":["Functional proton-beam stereotactic radiosurgery requires sub-millimeter alignment accuracy. A patient tracking system called Sequential Alignment and Position Verification System (SAVPS) is under development at Loma Linda University Medical Center. An optical positioning system (OPS), manufactured by Vicon Peak, has been chosen to verify the correct alignment of the target with the proton beam axis. The main objective of this thesis is to optimize an existing version of SAVPS by conducting error analysis. An image processing algorithm was developed and applied to estimate the error introduced by the Patient Positioning System (PPS) in order to derive the true error of the SAVPS."],"dc:identifier":["https://scholarworks.lib.csusb.edu/etd-project/2784"],"dc:subject":["Radiosurgery","Radiosurgery Quality control","Stereoencephalotomy","Stereoencephalotomy Quality control","Proton beams Therapeutic use","Protons Therapeutic use","Radiosurgery Instrumentation","Radiation dosimetry","Brain Tumors Radiotherapy","Radioisotope brachytherapy","Stereoencephalotomy.","Software Engineering"],"dc:title":["Optimization of a sequential alignment verification and positioning system (SAVPS) for proton radiosurgery"],"thesis:degree_discipline":["School of Computer Science and Engineering"],"thesis:degree_level":["Thesis"],"thesis:degree_name":["Master of Science in Computer Science"]},"updated_at":"2026-11-19T08:06:39Z"}