{"id":{"repo_id":"cz-tech","oai_identifier":"oai:dspace.cvut.cz:10467/104580"},"canonical_url":"https://search.ndltd.org/etd/cz-tech/oai:dspace.cvut.cz:10467/104580","repository":{"repo_id":"cz-tech","name":"Czech Technical University","base_url":"https://dspace.cvut.cz/server/oai/request"},"display":{"title":"Analýza propojení vysokofrekvenčního tryskového a CPAP ventilátoru","abstract":"Premature birth can be a cause for different diseases, to face this problem there are already existing ventilation supports in the clinical practice. For example, nowadays one of the approaches to treat neonates with respiratory diseases is using high-frequency jet ventilation in tandem with conventional ventilator. HFJV delivers high frequency breaths with the tidal volumes compared to the anatomical dead space, while expiration is passive due to chest recoil. Meanwhile conventional ventilator provides continuous pressure of air inside the lungs, keeping the respiratory system from collapsing. Continuous positive airway pressure ventilator can provide everything CV does in this ventilation circuit. Both respiratory support systems require a connector for the LifePort adapter of the HFJV to function. Since already existing versions of this connector for CPAP or CV and HFJV have some disadvantages concerning the high internal volume, it adds up to increasing the total dead space of the ventilation circuit. Increased total dead space consecutively increases the work of breathing of the patient. In case of prematurely born neonates, high work of breathing can cause a respiratory stress and develop into more severe complications. Therefore, the main aim of the thesis was to design the connector that would tolerate spontaneous breathing of the patient and have the least dead space possible, to reduce the total dead space of the ventilation circuit. This would lead to the reduction of the work of breathing of the patient. Multiple solutions of the problem were introduced, printed, and tested on the lung simulator. Work of breathing of the patient was evaluated and compared to already existing CV circuit to prove the efficiency of offered designs.","abstract_html":"Premature birth can be a cause for different diseases, to face this problem there are already existing ventilation supports in the clinical practice. For example, nowadays one of the approaches to treat neonates with respiratory diseases is using high-frequency jet ventilation in tandem with conventional ventilator. HFJV delivers high frequency breaths with the tidal volumes compared to the anatomical dead space, while expiration is passive due to chest recoil. Meanwhile conventional ventilator provides continuous pressure of air inside the lungs, keeping the respiratory system from collapsing. Continuous positive airway pressure ventilator can provide everything CV does in this ventilation circuit. Both respiratory support systems require a connector for the LifePort adapter of the HFJV to function. Since already existing versions of this connector for CPAP or CV and HFJV have some disadvantages concerning the high internal volume, it adds up to increasing the total dead space of the ventilation circuit. Increased total dead space consecutively increases the work of breathing of the patient. In case of prematurely born neonates, high work of breathing can cause a respiratory stress and develop into more severe complications. Therefore, the main aim of the thesis was to design the connector that would tolerate spontaneous breathing of the patient and have the least dead space possible, to reduce the total dead space of the ventilation circuit. This would lead to the reduction of the work of breathing of the patient. Multiple solutions of the problem were introduced, printed, and tested on the lung simulator. Work of breathing of the patient was evaluated and compared to already existing CV circuit to prove the efficiency of offered designs.","abstract_has_math":false,"creators":["Ivaneishvili, Luka","Luka Ivaneishvili"],"institution":"České vysoké učení technické v Praze","degree_name":null,"degree_level":null,"degree_discipline":null,"degree_department":null,"school":null,"contributors":[],"advisors":["Kudrna, Petr","Kudrna Petr"],"committee_chairs":[],"committee_members":["Bláha, Václav","Bláha Václav"],"year":2022,"date_issued":"2022-06-13","date_published":"2022-06-13","updated_at":"2026-11-28T18:41:19Z","subjects":["Continuous Positive Airway Pressure","CPAP","Imposed work of breathing","IWOB","High frequency jet ventilation","HFJV","Infant flow generator"],"languages":[],"rights":["A university thesis is a work protected by the Copyright Act of the Czech Republic. Extracts, copies and transcripts of the thesis are allowed for personal use only and at one`s own expense. The use of thesis should be in compliance with the Copyright Act.","Vysokoškolská závěrečná práce je dílo chráněné autorským zákonem. Je možné pořizovat z něj na své náklady a pro svoji osobní potřebu výpisy, opisy a rozmnoženiny. Jeho využití musí být v souladu s autorským zákonem v platném znění."],"rights_urls":[],"identifier_entries":[{"key":"dc:identifier","label":"Identifier","values":["KOS-1089127202305"],"render_values":[{"text":"KOS-1089127202305","href":null,"code":true}]}],"person_identifier_entries":[]},"links":{"outbound_url":"https://hdl.handle.net/10467/104580","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"https://hdl.handle.net/10467/104580","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Acz-tech%3Aoai%3Adspace.cvut.cz%3A10467%2F104580","prefix":"oai_dc"},"source_record":{"url":"https://dspace.cvut.cz/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Adspace.cvut.cz%3A10467%2F104580","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Kudrna, Petr","Kudrna Petr"]},{"key":"dc:contributor.committeemember","label":"Committee Member","values":["Bláha, Václav","Bláha Václav"]},{"key":"dc:creator","label":"Author","values":["Ivaneishvili, Luka","Luka Ivaneishvili"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2022-10-21T09:06:06Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2022-10-21T09:06:06Z"]},{"key":"dc:date.issued","label":"Date","values":["2022-06-13"]},{"key":"dc:publisher","label":"Institution","values":["České vysoké učení technické v Praze","Czech Technical University in Prague"]},{"key":"dc:relation.advisorentity","label":"Dc Relation Advisorentity","values":["53d04acf-f68a-4dd9-b3b9-c8b36971518a"]},{"key":"dc:type","label":"Dc Type","values":["bakalářská práce","bachelor thesis"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Continuous Positive Airway Pressure","CPAP","Imposed work of breathing","IWOB","High frequency jet ventilation","HFJV","Infant flow generator"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:rights","label":"Dc Rights","values":["A university thesis is a work protected by the Copyright Act of the Czech Republic. Extracts, copies and transcripts of the thesis are allowed for personal use only and at one`s own expense. The use of thesis should be in compliance with the Copyright Act.","Vysokoškolská závěrečná práce je dílo chráněné autorským zákonem. Je možné pořizovat z něj na své náklady a pro svoji osobní potřebu výpisy, opisy a rozmnoženiny. Jeho využití musí být v souladu s autorským zákonem v platném znění."]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["KOS-1089127202305"]},{"key":"dc:identifier.uri","label":"Identifier URI","values":["http://hdl.handle.net/10467/104580"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["Premature birth can be a cause for different diseases, to face this problem there are already existing ventilation supports in the clinical practice. For example, nowadays one of the approaches to treat neonates with respiratory diseases is using high-frequency jet ventilation in tandem with conventional ventilator. HFJV delivers high frequency breaths with the tidal volumes compared to the anatomical dead space, while expiration is passive due to chest recoil. Meanwhile conventional ventilator provides continuous pressure of air inside the lungs, keeping the respiratory system from collapsing. Continuous positive airway pressure ventilator can provide everything CV does in this ventilation circuit. Both respiratory support systems require a connector for the LifePort adapter of the HFJV to function. Since already existing versions of this connector for CPAP or CV and HFJV have some disadvantages concerning the high internal volume, it adds up to increasing the total dead space of the ventilation circuit. Increased total dead space consecutively increases the work of breathing of the patient. In case of prematurely born neonates, high work of breathing can cause a respiratory stress and develop into more severe complications. Therefore, the main aim of the thesis was to design the connector that would tolerate spontaneous breathing of the patient and have the least dead space possible, to reduce the total dead space of the ventilation circuit. This would lead to the reduction of the work of breathing of the patient. Multiple solutions of the problem were introduced, printed, and tested on the lung simulator. Work of breathing of the patient was evaluated and compared to already existing CV circuit to prove the efficiency of offered designs."]},{"key":"dc:title","label":"Title","values":["Analýza propojení vysokofrekvenčního tryskového a CPAP ventilátoru","Analysis of the connection between a high-frequency jet and a CPAP ventilator"]},{"key":"dspace:entity.type","label":"Dspace Entity Type","values":["Publication"]},{"key":"others:access_status","label":"Others Access Status","values":["open.access"]},{"key":"relation:isauthorofpublication","label":"Relation Isauthorofpublication","values":["e19a68ec-ca7b-46ad-bc23-f3bbf83e5062"]},{"key":"relation:isauthorofpublication.latestfordiscovery","label":"Relation Isauthorofpublication Latestfordiscovery","values":["e19a68ec-ca7b-46ad-bc23-f3bbf83e5062"]}]}],"canonical_facts":{"dc:contributor.advisor":["Kudrna, Petr","Kudrna Petr"],"dc:contributor.committeemember":["Bláha, Václav","Bláha Václav"],"dc:creator":["Ivaneishvili, Luka","Luka Ivaneishvili"],"dc:date.accessioned":["2022-10-21T09:06:06Z"],"dc:date.available":["2022-10-21T09:06:06Z"],"dc:date.issued":["2022-06-13"],"dc:description.abstract":["Premature birth can be a cause for different diseases, to face this problem there are already existing ventilation supports in the clinical practice. For example, nowadays one of the approaches to treat neonates with respiratory diseases is using high-frequency jet ventilation in tandem with conventional ventilator. HFJV delivers high frequency breaths with the tidal volumes compared to the anatomical dead space, while expiration is passive due to chest recoil. Meanwhile conventional ventilator provides continuous pressure of air inside the lungs, keeping the respiratory system from collapsing. Continuous positive airway pressure ventilator can provide everything CV does in this ventilation circuit. Both respiratory support systems require a connector for the LifePort adapter of the HFJV to function. Since already existing versions of this connector for CPAP or CV and HFJV have some disadvantages concerning the high internal volume, it adds up to increasing the total dead space of the ventilation circuit. Increased total dead space consecutively increases the work of breathing of the patient. In case of prematurely born neonates, high work of breathing can cause a respiratory stress and develop into more severe complications. Therefore, the main aim of the thesis was to design the connector that would tolerate spontaneous breathing of the patient and have the least dead space possible, to reduce the total dead space of the ventilation circuit. This would lead to the reduction of the work of breathing of the patient. Multiple solutions of the problem were introduced, printed, and tested on the lung simulator. Work of breathing of the patient was evaluated and compared to already existing CV circuit to prove the efficiency of offered designs."],"dc:identifier":["KOS-1089127202305"],"dc:identifier.uri":["http://hdl.handle.net/10467/104580"],"dc:publisher":["České vysoké učení technické v Praze","Czech Technical University in Prague"],"dc:relation.advisorentity":["53d04acf-f68a-4dd9-b3b9-c8b36971518a"],"dc:rights":["A university thesis is a work protected by the Copyright Act of the Czech Republic. Extracts, copies and transcripts of the thesis are allowed for personal use only and at one`s own expense. The use of thesis should be in compliance with the Copyright Act.","Vysokoškolská závěrečná práce je dílo chráněné autorským zákonem. Je možné pořizovat z něj na své náklady a pro svoji osobní potřebu výpisy, opisy a rozmnoženiny. Jeho využití musí být v souladu s autorským zákonem v platném znění."],"dc:subject":["Continuous Positive Airway Pressure","CPAP","Imposed work of breathing","IWOB","High frequency jet ventilation","HFJV","Infant flow generator"],"dc:title":["Analýza propojení vysokofrekvenčního tryskového a CPAP ventilátoru","Analysis of the connection between a high-frequency jet and a CPAP ventilator"],"dc:type":["bakalářská práce","bachelor thesis"],"dspace:entity.type":["Publication"],"others:access_status":["open.access"],"relation:isauthorofpublication":["e19a68ec-ca7b-46ad-bc23-f3bbf83e5062"],"relation:isauthorofpublication.latestfordiscovery":["e19a68ec-ca7b-46ad-bc23-f3bbf83e5062"]},"updated_at":"2026-11-28T18:41:19Z"}