{"id":{"repo_id":"dcu","oai_identifier":"oai:doras.dcu.ie:17237"},"canonical_url":"https://search.ndltd.org/etd/dcu/oai:doras.dcu.ie:17237","repository":{"repo_id":"dcu","name":"Dublin City University","base_url":"http://doras.dcu.ie/cgi/oai2"},"display":{"title":"Pharmaceutical water systems: a thermal-fluid analysis of pipe dead-legs","abstract":"The most commonly used technique for flow exchange, fluid isolation and removal in pharmaceutical water systems, is the installation of a branch tee with a conventional two-way outlet port valve. This however can create a stagnant or “dead-leg” zone, which is particularly hazardous as bacteria can accumulate and contaminate the entire water system. This project has involved the study of the thermal and fluid dynamics considerations within pipe dead-legs and their impact on high purity water systems. A detailed literature review of the technology surrounding pharmaceutical water systems was carried out to set the background for the analysis of pipe dead-legs. An experimental test rig was designed and constructed to represent a typical single loop water system incorporating a dead-leg test section. Results were obtained for a 6d, 4d and 2d branch tee configuration under dead-leg flow conditions. The effect of the main pipe loop velocity and temperature on the dead-leg end temperature was investigated. Determination of the temperature distribution along the axis of the dead-leg branch under steady state conditions was also investigated. It was shown that the maximum dead-leg end temperature increased for an increase in loop velocity for each configuration. Reducing the dead-leg length from a 6d to a 4d and 2d configuration respectively was shown to significantly increase the dead-leg end temperature. It was found that a zone of uniform temperature and a temperature decay region were present in each branch configuration respectively. It was shown that stagnant fluid was present at the end o f the dead-leg for the 6d and 4d configurations. The 2d dead-leg was found to be the most effective configuration to achieve full loop temperature penetration and mixing of the dead-leg fluid. The 6d rule was shown to be inadequate for both fluid mixing and loop temperature penetration.","abstract_html":"The most commonly used technique for flow exchange, fluid isolation and removal in pharmaceutical water systems, is the installation of a branch tee with a conventional two-way outlet port valve. This however can create a stagnant or “dead-leg” zone, which is particularly hazardous as bacteria can accumulate and contaminate the entire water system. This project has involved the study of the thermal and fluid dynamics considerations within pipe dead-legs and their impact on high purity water systems. A detailed literature review of the technology surrounding pharmaceutical water systems was carried out to set the background for the analysis of pipe dead-legs. An experimental test rig was designed and constructed to represent a typical single loop water system incorporating a dead-leg test section. Results were obtained for a 6d, 4d and 2d branch tee configuration under dead-leg flow conditions. The effect of the main pipe loop velocity and temperature on the dead-leg end temperature was investigated. Determination of the temperature distribution along the axis of the dead-leg branch under steady state conditions was also investigated. It was shown that the maximum dead-leg end temperature increased for an increase in loop velocity for each configuration. Reducing the dead-leg length from a 6d to a 4d and 2d configuration respectively was shown to significantly increase the dead-leg end temperature. It was found that a zone of uniform temperature and a temperature decay region were present in each branch configuration respectively. It was shown that stagnant fluid was present at the end o f the dead-leg for the 6d and 4d configurations. The 2d dead-leg was found to be the most effective configuration to achieve full loop temperature penetration and mixing of the dead-leg fluid. The 6d rule was shown to be inadequate for both fluid mixing and loop temperature penetration.","abstract_has_math":false,"creators":["Austen, Benjamin L."],"institution":"Dublin City University","degree_name":"meng","degree_level":"masters","degree_discipline":null,"degree_department":null,"school":null,"contributors":[],"advisors":[],"committee_chairs":[],"committee_members":[],"year":2005,"date_issued":"2005","date_published":"2005","updated_at":"2026-11-25T19:58:32Z","subjects":[],"languages":["en"],"rights":[],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"https://doras.dcu.ie/17237/","outbound_label":"Repository record","outbound_source":"dc:identifier.uri","record_url":"https://doras.dcu.ie/17237/","record_label":"Repository record","record_kind":"record","record_source":"dc:identifier.uri","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Adcu%3Aoai%3Adoras.dcu.ie%3A17237","prefix":"oai_dc"},"source_record":{"url":"http://doras.dcu.ie/cgi/oai2?verb=GetRecord&metadataPrefix=uketd_dc&identifier=oai%3Adoras.dcu.ie%3A17237","prefix":"uketd_dc"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:creator","label":"Author","values":["Austen, Benjamin L."]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["2005"]},{"key":"dc:date.issued","label":"Date","values":["2005"]},{"key":"dc:publisher.institution","label":"Dc Publisher Institution","values":["Dublin City University"]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]},{"key":"dc:type.qualificationlevel","label":"Dc Type Qualificationlevel","values":["masters"]},{"key":"dc:type.qualificationname","label":"Dc Type Qualificationname","values":["meng"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language","label":"Dc Language","values":["en"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://doras.dcu.ie/17237/"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["The most commonly used technique for flow exchange, fluid isolation and removal in pharmaceutical water systems, is the installation of a branch tee with a conventional two-way outlet port valve. This however can create a stagnant or “dead-leg” zone, which is particularly hazardous as bacteria can accumulate and contaminate the entire water system. This project has involved the study of the thermal and fluid dynamics considerations within pipe dead-legs and their impact on high purity water systems. A detailed literature review of the technology surrounding pharmaceutical water systems was carried out to set the background for the analysis of pipe dead-legs. An experimental test rig was designed and constructed to represent a typical single loop water system incorporating a dead-leg test section. Results were obtained for a 6d, 4d and 2d branch tee configuration under dead-leg flow conditions. The effect of the main pipe loop velocity and temperature on the dead-leg end temperature was investigated. Determination of the temperature distribution along the axis of the dead-leg branch under steady state conditions was also investigated. It was shown that the maximum dead-leg end temperature increased for an increase in loop velocity for each configuration. Reducing the dead-leg length from a 6d to a 4d and 2d configuration respectively was shown to significantly increase the dead-leg end temperature. It was found that a zone of uniform temperature and a temperature decay region were present in each branch configuration respectively. It was shown that stagnant fluid was present at the end o f the dead-leg for the 6d and 4d configurations. The 2d dead-leg was found to be the most effective configuration to achieve full loop temperature penetration and mixing of the dead-leg fluid. The 6d rule was shown to be inadequate for both fluid mixing and loop temperature penetration."]},{"key":"dc:format","label":"Dc Format","values":["application/pdf"]},{"key":"dcterms:accessrights","label":"Dcterms Accessrights","values":["public"]},{"key":"dc:title","label":"Title","values":["Pharmaceutical water systems: a thermal-fluid analysis of pipe dead-legs"]}]}],"canonical_facts":{"dc:creator":["Austen, Benjamin L."],"dc:date":["2005"],"dc:date.issued":["2005"],"dc:description.abstract":["The most commonly used technique for flow exchange, fluid isolation and removal in pharmaceutical water systems, is the installation of a branch tee with a conventional two-way outlet port valve. This however can create a stagnant or “dead-leg” zone, which is particularly hazardous as bacteria can accumulate and contaminate the entire water system. This project has involved the study of the thermal and fluid dynamics considerations within pipe dead-legs and their impact on high purity water systems. A detailed literature review of the technology surrounding pharmaceutical water systems was carried out to set the background for the analysis of pipe dead-legs. An experimental test rig was designed and constructed to represent a typical single loop water system incorporating a dead-leg test section. Results were obtained for a 6d, 4d and 2d branch tee configuration under dead-leg flow conditions. The effect of the main pipe loop velocity and temperature on the dead-leg end temperature was investigated. Determination of the temperature distribution along the axis of the dead-leg branch under steady state conditions was also investigated. It was shown that the maximum dead-leg end temperature increased for an increase in loop velocity for each configuration. Reducing the dead-leg length from a 6d to a 4d and 2d configuration respectively was shown to significantly increase the dead-leg end temperature. It was found that a zone of uniform temperature and a temperature decay region were present in each branch configuration respectively. It was shown that stagnant fluid was present at the end o f the dead-leg for the 6d and 4d configurations. The 2d dead-leg was found to be the most effective configuration to achieve full loop temperature penetration and mixing of the dead-leg fluid. The 6d rule was shown to be inadequate for both fluid mixing and loop temperature penetration."],"dc:format":["application/pdf"],"dc:identifier.uri":["https://doras.dcu.ie/17237/"],"dc:language":["en"],"dc:publisher.institution":["Dublin City University"],"dcterms:accessrights":["public"],"dc:title":["Pharmaceutical water systems: a thermal-fluid analysis of pipe dead-legs"],"dc:type":["Thesis"],"dc:type.qualificationlevel":["masters"],"dc:type.qualificationname":["meng"]},"updated_at":"2026-11-25T19:58:32Z"}