{"id":{"repo_id":"dcu","oai_identifier":"oai:doras.dcu.ie:18900"},"canonical_url":"https://search.ndltd.org/etd/dcu/oai:doras.dcu.ie:18900","repository":{"repo_id":"dcu","name":"Dublin City University","base_url":"http://doras.dcu.ie/cgi/oai2"},"display":{"title":"Fixed optics Fourier transform spectrometers with photodetector-arrays","abstract":"Two different types of stationary Fourier transform spectrometer, one of them based on a triangular interferometer and the second one based on a Savart-plate interferometer, were built and tested. The theoretical background that underlies the operation of fixed optics spectrometers is given as well as a description of the mathematical routines used for the reconstruction of the spectrum from the interferograms produced by a particular light source. Finally, the spectra of various light sources were measured and the performance limits and accuracy of the two instruments were established.","abstract_html":"Two different types of stationary Fourier transform spectrometer, one of them based on a triangular interferometer and the second one based on a Savart-plate interferometer, were built and tested. The theoretical background that underlies the operation of fixed optics spectrometers is given as well as a description of the mathematical routines used for the reconstruction of the spectrum from the interferograms produced by a particular light source. Finally, the spectra of various light sources were measured and the performance limits and accuracy of the two instruments were established.","abstract_has_math":false,"creators":["Kalisch, Dirk Christian"],"institution":"Dublin City University","degree_name":"msc","degree_level":"masters","degree_discipline":null,"degree_department":null,"school":null,"contributors":[],"advisors":[],"committee_chairs":[],"committee_members":[],"year":1997,"date_issued":"1997","date_published":"1997","updated_at":"2026-11-25T19:58:49Z","subjects":[],"languages":["en"],"rights":[],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"https://doras.dcu.ie/18900/","outbound_label":"Repository record","outbound_source":"dc:identifier.uri","record_url":"https://doras.dcu.ie/18900/","record_label":"Repository record","record_kind":"record","record_source":"dc:identifier.uri","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Adcu%3Aoai%3Adoras.dcu.ie%3A18900","prefix":"oai_dc"},"source_record":{"url":"http://doras.dcu.ie/cgi/oai2?verb=GetRecord&metadataPrefix=uketd_dc&identifier=oai%3Adoras.dcu.ie%3A18900","prefix":"uketd_dc"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:creator","label":"Author","values":["Kalisch, Dirk Christian"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["1997"]},{"key":"dc:date.issued","label":"Date","values":["1997"]},{"key":"dc:publisher.institution","label":"Dc Publisher Institution","values":["Dublin City University"]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]},{"key":"dc:type.qualificationlevel","label":"Dc Type Qualificationlevel","values":["masters"]},{"key":"dc:type.qualificationname","label":"Dc Type Qualificationname","values":["msc"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language","label":"Dc Language","values":["en"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://doras.dcu.ie/18900/"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["Two different types of stationary Fourier transform spectrometer, one of them based on a triangular interferometer and the second one based on a Savart-plate interferometer, were built and tested. The theoretical background that underlies the operation of fixed optics spectrometers is given as well as a description of the mathematical routines used for the reconstruction of the spectrum from the interferograms produced by a particular light source. Finally, the spectra of various light sources were measured and the performance limits and accuracy of the two instruments were established."]},{"key":"dc:format","label":"Dc Format","values":["application/pdf"]},{"key":"dcterms:accessrights","label":"Dcterms Accessrights","values":["public"]},{"key":"dc:title","label":"Title","values":["Fixed optics Fourier transform spectrometers with photodetector-arrays"]}]}],"canonical_facts":{"dc:creator":["Kalisch, Dirk Christian"],"dc:date":["1997"],"dc:date.issued":["1997"],"dc:description.abstract":["Two different types of stationary Fourier transform spectrometer, one of them based on a triangular interferometer and the second one based on a Savart-plate interferometer, were built and tested. The theoretical background that underlies the operation of fixed optics spectrometers is given as well as a description of the mathematical routines used for the reconstruction of the spectrum from the interferograms produced by a particular light source. Finally, the spectra of various light sources were measured and the performance limits and accuracy of the two instruments were established."],"dc:format":["application/pdf"],"dc:identifier.uri":["https://doras.dcu.ie/18900/"],"dc:language":["en"],"dc:publisher.institution":["Dublin City University"],"dcterms:accessrights":["public"],"dc:title":["Fixed optics Fourier transform spectrometers with photodetector-arrays"],"dc:type":["Thesis"],"dc:type.qualificationlevel":["masters"],"dc:type.qualificationname":["msc"]},"updated_at":"2026-11-25T19:58:49Z"}