{"id":{"repo_id":"dcu","oai_identifier":"oai:doras.dcu.ie:18931"},"canonical_url":"https://search.ndltd.org/etd/dcu/oai:doras.dcu.ie:18931","repository":{"repo_id":"dcu","name":"Dublin City University","base_url":"http://doras.dcu.ie/cgi/oai2"},"display":{"title":"Strain and strain gradient measurement using fibre bragg grating sensors","abstract":"The use of apodised in-fibre Bragg gratings in the measurement of both strain and strain gradient is discussed. A system of two Bragg gratings of similar but slightly displaced Bragg wavelength, joined using a 3dB coupler was used with a specially designed spectrum analyser of approximately nine picometers wavelength resolution. This consisted of a scanning Fabry Perot interference filter and photodiode detector unit interfaced to a PC. The reflection spectrum of both gratings, one exposed to strain, the other used as a temperature-referencing channel, was constructed using a Voigt type deconvolution. A directed evolution software algorithm was used as a line fitting routine to extract both the Bragg wavelengths and linewidths of the light back reflected from the gratings. A cantilever type strain rig in a temperature-controlled environment was used to create known strain and strain gradient fields. The variations in the Bragg wavelength with strain over a -400 to +600 microstrain range was measured from which the strain sensitivity of 0.962 ± 0.002 pm/microstrain, at ~1300nm was determined. The temperature sensitivity was also evaluated. The linewidth of the back reflected spectrum from the Bragg grating was measured as a function of strain gradient (g) over the range - 1.0 to +1.5 microstrain per mm and was'fitted to a quadratic in g . This functional form was explained using a model based on coupled mode theory applied to apodised gratings.","abstract_html":"The use of apodised in-fibre Bragg gratings in the measurement of both strain and strain gradient is discussed. A system of two Bragg gratings of similar but slightly displaced Bragg wavelength, joined using a 3dB coupler was used with a specially designed spectrum analyser of approximately nine picometers wavelength resolution. This consisted of a scanning Fabry Perot interference filter and photodiode detector unit interfaced to a PC. The reflection spectrum of both gratings, one exposed to strain, the other used as a temperature-referencing channel, was constructed using a Voigt type deconvolution. A directed evolution software algorithm was used as a line fitting routine to extract both the Bragg wavelengths and linewidths of the light back reflected from the gratings. A cantilever type strain rig in a temperature-controlled environment was used to create known strain and strain gradient fields. The variations in the Bragg wavelength with strain over a -400 to +600 microstrain range was measured from which the strain sensitivity of 0.962 ± 0.002 pm/microstrain, at ~1300nm was determined. The temperature sensitivity was also evaluated. The linewidth of the back reflected spectrum from the Bragg grating was measured as a function of strain gradient (g) over the range - 1.0 to +1.5 microstrain per mm and was&#x27;fitted to a quadratic in g . This functional form was explained using a model based on coupled mode theory applied to apodised gratings.","abstract_has_math":false,"creators":["Kennedy, Michael C"],"institution":"Dublin City University","degree_name":"phd","degree_level":"doctoral","degree_discipline":null,"degree_department":null,"school":null,"contributors":[],"advisors":[],"committee_chairs":[],"committee_members":[],"year":1999,"date_issued":"1999","date_published":"1999","updated_at":"2026-11-25T19:58:49Z","subjects":[],"languages":["en"],"rights":[],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"https://doras.dcu.ie/18931/","outbound_label":"Repository record","outbound_source":"dc:identifier.uri","record_url":"https://doras.dcu.ie/18931/","record_label":"Repository record","record_kind":"record","record_source":"dc:identifier.uri","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Adcu%3Aoai%3Adoras.dcu.ie%3A18931","prefix":"oai_dc"},"source_record":{"url":"http://doras.dcu.ie/cgi/oai2?verb=GetRecord&metadataPrefix=uketd_dc&identifier=oai%3Adoras.dcu.ie%3A18931","prefix":"uketd_dc"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:creator","label":"Author","values":["Kennedy, Michael C"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["1999"]},{"key":"dc:date.issued","label":"Date","values":["1999"]},{"key":"dc:publisher.institution","label":"Dc Publisher Institution","values":["Dublin City University"]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]},{"key":"dc:type.qualificationlevel","label":"Dc Type Qualificationlevel","values":["doctoral"]},{"key":"dc:type.qualificationname","label":"Dc Type Qualificationname","values":["phd"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language","label":"Dc Language","values":["en"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://doras.dcu.ie/18931/"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["The use of apodised in-fibre Bragg gratings in the measurement of both strain and strain gradient is discussed. A system of two Bragg gratings of similar but slightly displaced Bragg wavelength, joined using a 3dB coupler was used with a specially designed spectrum analyser of approximately nine picometers wavelength resolution. This consisted of a scanning Fabry Perot interference filter and photodiode detector unit interfaced to a PC. The reflection spectrum of both gratings, one exposed to strain, the other used as a temperature-referencing channel, was constructed using a Voigt type deconvolution. A directed evolution software algorithm was used as a line fitting routine to extract both the Bragg wavelengths and linewidths of the light back reflected from the gratings. A cantilever type strain rig in a temperature-controlled environment was used to create known strain and strain gradient fields. The variations in the Bragg wavelength with strain over a -400 to +600 microstrain range was measured from which the strain sensitivity of 0.962 ± 0.002 pm/microstrain, at ~1300nm was determined. The temperature sensitivity was also evaluated. The linewidth of the back reflected spectrum from the Bragg grating was measured as a function of strain gradient (g) over the range - 1.0 to +1.5 microstrain per mm and was'fitted to a quadratic in g . This functional form was explained using a model based on coupled mode theory applied to apodised gratings."]},{"key":"dc:format","label":"Dc Format","values":["application/pdf"]},{"key":"dcterms:accessrights","label":"Dcterms Accessrights","values":["public"]},{"key":"dc:title","label":"Title","values":["Strain and strain gradient measurement using fibre bragg grating sensors"]}]}],"canonical_facts":{"dc:creator":["Kennedy, Michael C"],"dc:date":["1999"],"dc:date.issued":["1999"],"dc:description.abstract":["The use of apodised in-fibre Bragg gratings in the measurement of both strain and strain gradient is discussed. A system of two Bragg gratings of similar but slightly displaced Bragg wavelength, joined using a 3dB coupler was used with a specially designed spectrum analyser of approximately nine picometers wavelength resolution. This consisted of a scanning Fabry Perot interference filter and photodiode detector unit interfaced to a PC. The reflection spectrum of both gratings, one exposed to strain, the other used as a temperature-referencing channel, was constructed using a Voigt type deconvolution. A directed evolution software algorithm was used as a line fitting routine to extract both the Bragg wavelengths and linewidths of the light back reflected from the gratings. A cantilever type strain rig in a temperature-controlled environment was used to create known strain and strain gradient fields. The variations in the Bragg wavelength with strain over a -400 to +600 microstrain range was measured from which the strain sensitivity of 0.962 ± 0.002 pm/microstrain, at ~1300nm was determined. The temperature sensitivity was also evaluated. The linewidth of the back reflected spectrum from the Bragg grating was measured as a function of strain gradient (g) over the range - 1.0 to +1.5 microstrain per mm and was'fitted to a quadratic in g . This functional form was explained using a model based on coupled mode theory applied to apodised gratings."],"dc:format":["application/pdf"],"dc:identifier.uri":["https://doras.dcu.ie/18931/"],"dc:language":["en"],"dc:publisher.institution":["Dublin City University"],"dcterms:accessrights":["public"],"dc:title":["Strain and strain gradient measurement using fibre bragg grating sensors"],"dc:type":["Thesis"],"dc:type.qualificationlevel":["doctoral"],"dc:type.qualificationname":["phd"]},"updated_at":"2026-11-25T19:58:49Z"}