{"id":{"repo_id":"dcu","oai_identifier":"oai:doras.dcu.ie:20791"},"canonical_url":"https://search.ndltd.org/etd/dcu/oai:doras.dcu.ie:20791","repository":{"repo_id":"dcu","name":"Dublin City University","base_url":"http://doras.dcu.ie/cgi/oai2"},"display":{"title":"Development of a microfluidic device and imaging system for the monitoring of anti-platelet therapy","abstract":"This work details the development of two distinct prototype point-of-care diagnostic systems to be used to determine the ecacy of anti-platelet ther- apies. Novel micro uidic chips were designed for each system, to enable the on-chip testing of multiple anti-platelet therapies. The prototypes work with whole blood and integrate with a new detection method used to de- termine the percentage of platelets adhered to an array of brinogen spots. The system uses customised image analysis software to objectively quantify single platelet binding events from a single blood sample, without the need to add any form of labelling to the blood. The system was validated by comparing the percentage of platelets adhered from `normal' blood samples compared to samples treated with an established platelet therapy. These treatments inhibit a specic receptor on the platelet surface, thus inter- fering with stable adhesion to brinogen, rendering platelets \\less sticky\". This prototype point-of-care device could allow for the automated testing of large numbers of patient samples, potentially diagnosing individuals at risk of suering a cardiovascular event or undiagnosed bleeding disorder.","abstract_html":"This work details the development of two distinct prototype point-of-care diagnostic systems to be used to determine the ecacy of anti-platelet ther- apies. Novel micro uidic chips were designed for each system, to enable the on-chip testing of multiple anti-platelet therapies. The prototypes work with whole blood and integrate with a new detection method used to de- termine the percentage of platelets adhered to an array of brinogen spots. The system uses customised image analysis software to objectively quantify single platelet binding events from a single blood sample, without the need to add any form of labelling to the blood. The system was validated by comparing the percentage of platelets adhered from `normal&#x27; blood samples compared to samples treated with an established platelet therapy. These treatments inhibit a specic receptor on the platelet surface, thus inter- fering with stable adhesion to brinogen, rendering platelets \\less sticky&quot;. This prototype point-of-care device could allow for the automated testing of large numbers of patient samples, potentially diagnosing individuals at risk of suering a cardiovascular event or undiagnosed bleeding disorder.","abstract_has_math":false,"creators":["McCluskey, Peter"],"institution":"Dublin City University","degree_name":"phd","degree_level":"doctoral","degree_discipline":null,"degree_department":null,"school":null,"contributors":[],"advisors":[],"committee_chairs":[],"committee_members":[],"year":2015,"date_issued":"2015-11","date_published":"2015-11","updated_at":"2026-11-25T19:59:03Z","subjects":[],"languages":["en"],"rights":[],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"https://doras.dcu.ie/20791/","outbound_label":"Repository record","outbound_source":"dc:identifier.uri","record_url":"https://doras.dcu.ie/20791/","record_label":"Repository record","record_kind":"record","record_source":"dc:identifier.uri","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Adcu%3Aoai%3Adoras.dcu.ie%3A20791","prefix":"oai_dc"},"source_record":{"url":"http://doras.dcu.ie/cgi/oai2?verb=GetRecord&metadataPrefix=uketd_dc&identifier=oai%3Adoras.dcu.ie%3A20791","prefix":"uketd_dc"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.sponsor","label":"Sponsor","values":["SFI"]},{"key":"dc:creator","label":"Author","values":["McCluskey, Peter"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["2015-11"]},{"key":"dc:date.issued","label":"Date","values":["2015-11"]},{"key":"dc:publisher.institution","label":"Dc Publisher Institution","values":["Dublin City University"]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]},{"key":"dc:type.qualificationlevel","label":"Dc Type Qualificationlevel","values":["doctoral"]},{"key":"dc:type.qualificationname","label":"Dc Type Qualificationname","values":["phd"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language","label":"Dc Language","values":["en"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://doras.dcu.ie/20791/"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["This work details the development of two distinct prototype point-of-care diagnostic systems to be used to determine the ecacy of anti-platelet ther- apies. Novel micro uidic chips were designed for each system, to enable the on-chip testing of multiple anti-platelet therapies. The prototypes work with whole blood and integrate with a new detection method used to de- termine the percentage of platelets adhered to an array of brinogen spots. The system uses customised image analysis software to objectively quantify single platelet binding events from a single blood sample, without the need to add any form of labelling to the blood. The system was validated by comparing the percentage of platelets adhered from `normal' blood samples compared to samples treated with an established platelet therapy. These treatments inhibit a specic receptor on the platelet surface, thus inter- fering with stable adhesion to brinogen, rendering platelets \\less sticky\". This prototype point-of-care device could allow for the automated testing of large numbers of patient samples, potentially diagnosing individuals at risk of suering a cardiovascular event or undiagnosed bleeding disorder."]},{"key":"dc:format","label":"Dc Format","values":["application/pdf"]},{"key":"dcterms:accessrights","label":"Dcterms Accessrights","values":["public"]},{"key":"dc:title","label":"Title","values":["Development of a microfluidic device and imaging system for the monitoring of anti-platelet therapy"]}]}],"canonical_facts":{"dc:contributor.sponsor":["SFI"],"dc:creator":["McCluskey, Peter"],"dc:date":["2015-11"],"dc:date.issued":["2015-11"],"dc:description.abstract":["This work details the development of two distinct prototype point-of-care diagnostic systems to be used to determine the ecacy of anti-platelet ther- apies. Novel micro uidic chips were designed for each system, to enable the on-chip testing of multiple anti-platelet therapies. The prototypes work with whole blood and integrate with a new detection method used to de- termine the percentage of platelets adhered to an array of brinogen spots. The system uses customised image analysis software to objectively quantify single platelet binding events from a single blood sample, without the need to add any form of labelling to the blood. The system was validated by comparing the percentage of platelets adhered from `normal' blood samples compared to samples treated with an established platelet therapy. These treatments inhibit a specic receptor on the platelet surface, thus inter- fering with stable adhesion to brinogen, rendering platelets \\less sticky\". This prototype point-of-care device could allow for the automated testing of large numbers of patient samples, potentially diagnosing individuals at risk of suering a cardiovascular event or undiagnosed bleeding disorder."],"dc:format":["application/pdf"],"dc:identifier.uri":["https://doras.dcu.ie/20791/"],"dc:language":["en"],"dc:publisher.institution":["Dublin City University"],"dcterms:accessrights":["public"],"dc:title":["Development of a microfluidic device and imaging system for the monitoring of anti-platelet therapy"],"dc:type":["Thesis"],"dc:type.qualificationlevel":["doctoral"],"dc:type.qualificationname":["phd"]},"updated_at":"2026-11-25T19:59:03Z"}