{"id":{"repo_id":"dcu","oai_identifier":"oai:doras.dcu.ie:30229"},"canonical_url":"https://search.ndltd.org/etd/dcu/oai:doras.dcu.ie:30229","repository":{"repo_id":"dcu","name":"Dublin City University","base_url":"http://doras.dcu.ie/cgi/oai2"},"display":{"title":"3D Printed Medical-Grade Metal-based Microneedles as a Modular Platform for Minimally Invasive Therapeutic Delivery","abstract":"Microneedles (MNs) enhance transdermal drug delivery (TDD) by enabling better drug absorption and avoiding pain and needle-related risks, thereby improving treatment for chronic conditions and enhancing patient comfort. This study introduces optimised 3D-printed stainless-steel MN arrays coated with biocompatible polymers. Conical-shaped MNs (36 MNs/patch) were fabricated using the direct metal laser melting process and optimised through a Design of Experiments approach. Optimal MNs, with a height of ~780 μm and tip diameter ~25 μm, with reduced roughness, were developed. These MNs demonstrated a skin penetration depth ranging between 400-700 μm without the potential for reaching the pain receptors. Ex vivo studies on porcine skin demonstrated the efficacy of the MNs since a force of ~4 N is required for them to penetrate the stratum corneum with no tip fracture. MNs were dip-coated with poly(vinyl alcohol) (PVA), polyvinylpyrrolidone (PVP), and carboxymethyl cellulose (CMC) loaded with Rhodamine B (RhoB, Mw=479.02 g/mol) as a model drug. A 5-layer coating with 10% PVA-RhoB, 20% PVP-RhoB or 8% CMC-RhoB resulted in a homogeneous coating on MNs without affecting the geometrical characteristics or the penetration depth, leading to a drug loading capacity of 11.0±2.0 μg, 15.0±1.5 μg and 12.5±3.0 μg respectively. PVA/PVP/CMC-RhoB coated-MNs resulted in 60-80% drug delivery to porcine skin within 5 min of MN application. Additionally, the 2-h in vitro permeation study presented slower drug permeation for PVA RhoB and CMC-RhoB, with a steady-state flux (J) ranging from 0.017-0.044 (μg/cm2)/min, than PVP-RhoB (J=0.23 (μg/cm2)/min). Despite differing kinetics, all polymers achieved 80-95% drug permeation after 2-h. The coated metallic-MN technology offers a promising solution to the limitations of current TDD systems, providing a painless and controllable method for drug administration. Future work includes in vivo studies to verify efficacy, and potential applications in managing pain and chronic illnesses, aiming for a minimally invasive and patient-compliant delivery system.","abstract_html":"Microneedles (MNs) enhance transdermal drug delivery (TDD) by enabling better drug absorption and avoiding pain and needle-related risks, thereby improving treatment for chronic conditions and enhancing patient comfort. This study introduces optimised 3D-printed stainless-steel MN arrays coated with biocompatible polymers. Conical-shaped MNs (36 MNs/patch) were fabricated using the direct metal laser melting process and optimised through a Design of Experiments approach. Optimal MNs, with a height of ~780 μm and tip diameter ~25 μm, with reduced roughness, were developed. These MNs demonstrated a skin penetration depth ranging between 400-700 μm without the potential for reaching the pain receptors. Ex vivo studies on porcine skin demonstrated the efficacy of the MNs since a force of ~4 N is required for them to penetrate the stratum corneum with no tip fracture. MNs were dip-coated with poly(vinyl alcohol) (PVA), polyvinylpyrrolidone (PVP), and carboxymethyl cellulose (CMC) loaded with Rhodamine B (RhoB, Mw=479.02 g/mol) as a model drug. A 5-layer coating with 10% PVA-RhoB, 20% PVP-RhoB or 8% CMC-RhoB resulted in a homogeneous coating on MNs without affecting the geometrical characteristics or the penetration depth, leading to a drug loading capacity of 11.0±2.0 μg, 15.0±1.5 μg and 12.5±3.0 μg respectively. PVA/PVP/CMC-RhoB coated-MNs resulted in 60-80% drug delivery to porcine skin within 5 min of MN application. Additionally, the 2-h in vitro permeation study presented slower drug permeation for PVA RhoB and CMC-RhoB, with a steady-state flux (J) ranging from 0.017-0.044 (μg/cm2)/min, than PVP-RhoB (J=0.23 (μg/cm2)/min). Despite differing kinetics, all polymers achieved 80-95% drug permeation after 2-h. The coated metallic-MN technology offers a promising solution to the limitations of current TDD systems, providing a painless and controllable method for drug administration. Future work includes in vivo studies to verify efficacy, and potential applications in managing pain and chronic illnesses, aiming for a minimally invasive and patient-compliant delivery system.","abstract_has_math":false,"creators":["Sargioti, Nikoletta"],"institution":"Dublin City University","degree_name":"phd","degree_level":"doctoral","degree_discipline":null,"degree_department":null,"school":null,"contributors":[],"advisors":[],"committee_chairs":[],"committee_members":[],"year":2024,"date_issued":"2024-08","date_published":"2024-08","updated_at":"2026-11-25T19:59:12Z","subjects":[],"languages":["en"],"rights":[],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"https://doras.dcu.ie/30229/","outbound_label":"Repository record","outbound_source":"dc:identifier.uri","record_url":"https://doras.dcu.ie/30229/","record_label":"Repository record","record_kind":"record","record_source":"dc:identifier.uri","access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"http://doras.dcu.ie/cgi/oai2?verb=GetRecord&metadataPrefix=uketd_dc&identifier=oai%3Adoras.dcu.ie%3A30229","prefix":"uketd_dc"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.sponsor","label":"Sponsor","values":["Science Foundation Ireland","Engineering Physical Science Research Council"]},{"key":"dc:creator","label":"Author","values":["Sargioti, Nikoletta"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["2024-08"]},{"key":"dc:date.issued","label":"Date","values":["2024-08"]},{"key":"dc:publisher.institution","label":"Dc Publisher Institution","values":["Dublin City University"]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]},{"key":"dc:type.qualificationlevel","label":"Dc Type Qualificationlevel","values":["doctoral"]},{"key":"dc:type.qualificationname","label":"Dc Type Qualificationname","values":["phd"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language","label":"Dc Language","values":["en"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://doras.dcu.ie/30229/"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["Microneedles (MNs) enhance transdermal drug delivery (TDD) by enabling better drug absorption and avoiding pain and needle-related risks, thereby improving treatment for chronic conditions and enhancing patient comfort. This study introduces optimised 3D-printed stainless-steel MN arrays coated with biocompatible polymers. Conical-shaped MNs (36 MNs/patch) were fabricated using the direct metal laser melting process and optimised through a Design of Experiments approach. Optimal MNs, with a height of ~780 μm and tip diameter ~25 μm, with reduced roughness, were developed. These MNs demonstrated a skin penetration depth ranging between 400-700 μm without the potential for reaching the pain receptors. Ex vivo studies on porcine skin demonstrated the efficacy of the MNs since a force of ~4 N is required for them to penetrate the stratum corneum with no tip fracture. MNs were dip-coated with poly(vinyl alcohol) (PVA), polyvinylpyrrolidone (PVP), and carboxymethyl cellulose (CMC) loaded with Rhodamine B (RhoB, Mw=479.02 g/mol) as a model drug. A 5-layer coating with 10% PVA-RhoB, 20% PVP-RhoB or 8% CMC-RhoB resulted in a homogeneous coating on MNs without affecting the geometrical characteristics or the penetration depth, leading to a drug loading capacity of 11.0±2.0 μg, 15.0±1.5 μg and 12.5±3.0 μg respectively. PVA/PVP/CMC-RhoB coated-MNs resulted in 60-80% drug delivery to porcine skin within 5 min of MN application. Additionally, the 2-h in vitro permeation study presented slower drug permeation for PVA RhoB and CMC-RhoB, with a steady-state flux (J) ranging from 0.017-0.044 (μg/cm2)/min, than PVP-RhoB (J=0.23 (μg/cm2)/min). Despite differing kinetics, all polymers achieved 80-95% drug permeation after 2-h. The coated metallic-MN technology offers a promising solution to the limitations of current TDD systems, providing a painless and controllable method for drug administration. Future work includes in vivo studies to verify efficacy, and potential applications in managing pain and chronic illnesses, aiming for a minimally invasive and patient-compliant delivery system."]},{"key":"dc:format","label":"Dc Format","values":["application/pdf"]},{"key":"dcterms:accessrights","label":"Dcterms Accessrights","values":["public"]},{"key":"dc:title","label":"Title","values":["3D Printed Medical-Grade Metal-based Microneedles as a Modular Platform for Minimally Invasive Therapeutic Delivery"]}]}],"canonical_facts":{"dc:contributor.sponsor":["Science Foundation Ireland","Engineering Physical Science Research Council"],"dc:creator":["Sargioti, Nikoletta"],"dc:date":["2024-08"],"dc:date.issued":["2024-08"],"dc:description.abstract":["Microneedles (MNs) enhance transdermal drug delivery (TDD) by enabling better drug absorption and avoiding pain and needle-related risks, thereby improving treatment for chronic conditions and enhancing patient comfort. This study introduces optimised 3D-printed stainless-steel MN arrays coated with biocompatible polymers. Conical-shaped MNs (36 MNs/patch) were fabricated using the direct metal laser melting process and optimised through a Design of Experiments approach. Optimal MNs, with a height of ~780 μm and tip diameter ~25 μm, with reduced roughness, were developed. These MNs demonstrated a skin penetration depth ranging between 400-700 μm without the potential for reaching the pain receptors. Ex vivo studies on porcine skin demonstrated the efficacy of the MNs since a force of ~4 N is required for them to penetrate the stratum corneum with no tip fracture. MNs were dip-coated with poly(vinyl alcohol) (PVA), polyvinylpyrrolidone (PVP), and carboxymethyl cellulose (CMC) loaded with Rhodamine B (RhoB, Mw=479.02 g/mol) as a model drug. A 5-layer coating with 10% PVA-RhoB, 20% PVP-RhoB or 8% CMC-RhoB resulted in a homogeneous coating on MNs without affecting the geometrical characteristics or the penetration depth, leading to a drug loading capacity of 11.0±2.0 μg, 15.0±1.5 μg and 12.5±3.0 μg respectively. PVA/PVP/CMC-RhoB coated-MNs resulted in 60-80% drug delivery to porcine skin within 5 min of MN application. Additionally, the 2-h in vitro permeation study presented slower drug permeation for PVA RhoB and CMC-RhoB, with a steady-state flux (J) ranging from 0.017-0.044 (μg/cm2)/min, than PVP-RhoB (J=0.23 (μg/cm2)/min). Despite differing kinetics, all polymers achieved 80-95% drug permeation after 2-h. The coated metallic-MN technology offers a promising solution to the limitations of current TDD systems, providing a painless and controllable method for drug administration. Future work includes in vivo studies to verify efficacy, and potential applications in managing pain and chronic illnesses, aiming for a minimally invasive and patient-compliant delivery system."],"dc:format":["application/pdf"],"dc:identifier.uri":["https://doras.dcu.ie/30229/"],"dc:language":["en"],"dc:publisher.institution":["Dublin City University"],"dcterms:accessrights":["public"],"dc:title":["3D Printed Medical-Grade Metal-based Microneedles as a Modular Platform for Minimally Invasive Therapeutic Delivery"],"dc:type":["Thesis"],"dc:type.qualificationlevel":["doctoral"],"dc:type.qualificationname":["phd"]},"updated_at":"2026-11-25T19:59:12Z"}