{"id":{"repo_id":"denver","oai_identifier":"oai:digitalcommons.du.edu:etd-1048"},"canonical_url":"https://search.ndltd.org/etd/denver/oai:digitalcommons.du.edu:etd-1048","repository":{"repo_id":"denver","name":"University of Denver","base_url":"https://digitalcommons.du.edu/do/oai/"},"display":{"title":"Development of Wearable Sensors for Body Joint Angle Measurement","abstract":"This thesis presents the development of three different methods for body joint angle measurement using wearable sensors. Continuous monitoring of patients' movements and activities has recently become one of the active research areas in the field of body sensor network and telehealth monitoring. For many medical and rehabilitation applications, a continuous monitor of the patients' daily activities at home without visiting the hospital is desirable. This type of monitoring is beneficial for the therapists and physicians as it does not require patients' physical presence. Traditionally, measuring the range of motion (ROM) is performed in hospitals by utilizing standard tools such as a goniometer. This method needs to be fulfilled by a physiotherapist in the hospital and requires great deal of overhead. Thus, a remote sensing technique for monitoring the progress of body joint flexion during regular daily life activities becomes very beneficial. The main focus of this thesis is on developing different methods for sensing body joint angle, although we developed some mechanisms for transmitting measurements from patient's side to a remote server at the hospital. The first method for measuring the joint angle- specifically the knee joint- is based on an encoder attached to a brace. The second method is performed by utilizing a wearable cloth with flex-sensors. In the third method, inertial measurement units (IMUs) are employed to measure the desired joint angle. We conducted several experiments to compare the feasibility and accuracy of each method for angle measurement with ground truth measurements. The advantages and disadvantages of each approach are discussed and explained in detail in the assigned section.","abstract_html":"This thesis presents the development of three different methods for body joint angle measurement using wearable sensors. Continuous monitoring of patients&#x27; movements and activities has recently become one of the active research areas in the field of body sensor network and telehealth monitoring. For many medical and rehabilitation applications, a continuous monitor of the patients&#x27; daily activities at home without visiting the hospital is desirable. This type of monitoring is beneficial for the therapists and physicians as it does not require patients&#x27; physical presence. Traditionally, measuring the range of motion (ROM) is performed in hospitals by utilizing standard tools such as a goniometer. This method needs to be fulfilled by a physiotherapist in the hospital and requires great deal of overhead. Thus, a remote sensing technique for monitoring the progress of body joint flexion during regular daily life activities becomes very beneficial. The main focus of this thesis is on developing different methods for sensing body joint angle, although we developed some mechanisms for transmitting measurements from patient&#x27;s side to a remote server at the hospital. The first method for measuring the joint angle- specifically the knee joint- is based on an encoder attached to a brace. The second method is performed by utilizing a wearable cloth with flex-sensors. In the third method, inertial measurement units (IMUs) are employed to measure the desired joint angle. We conducted several experiments to compare the feasibility and accuracy of each method for angle measurement with ground truth measurements. The advantages and disadvantages of each approach are discussed and explained in detail in the assigned section.","abstract_has_math":false,"creators":["Bakhshi Khayani, Saba"],"institution":null,"degree_name":"M.S.","degree_level":"Masters Thesis","degree_discipline":null,"degree_department":null,"school":null,"contributors":["Mohammad H. Mahoor, Ph.D."],"advisors":[],"committee_chairs":[],"committee_members":[],"year":null,"date_issued":"","date_published":null,"updated_at":"2026-11-19T07:54:59Z","subjects":["Wearable sensors","Range of motion (ROM)","Inertial measurement units (IMUs)","Electrical and Computer Engineering","Engineering"],"languages":["en"],"rights":["<p>Copyright is held by the author. User is responsible for all copyright compliance.</p>","Saba Bakhshi Khayani"],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"https://digitalcommons.du.edu/etd/49","outbound_label":"Repository record","outbound_source":"dc:identifier","record_url":"https://digitalcommons.du.edu/etd/49","record_label":"Repository record","record_kind":"record","record_source":"dc:identifier","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://digitalcommons.du.edu/do/oai/?verb=GetRecord&metadataPrefix=oai_etdms&identifier=oai%3Adigitalcommons.du.edu%3Aetd-1048","prefix":"oai_etdms"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor","label":"Contributor","values":["Mohammad H. Mahoor, Ph.D."]},{"key":"dc:creator","label":"Author","values":["Bakhshi Khayani, Saba"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.available","label":"Dc Date Available","values":["2001-01-01T08:00:00Z"]},{"key":"dc:date.copyright","label":"Dc Date Copyright","values":["2011-06-01T07:00:00Z"]},{"key":"dc:date.created","label":"Dc Date Created","values":["2011-06-01T07:00:00Z"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Masters Thesis"]},{"key":"thesis:degree_name","label":"Degree Name","values":["M.S."]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Wearable sensors","Range of motion (ROM)","Inertial measurement units (IMUs)","Electrical and Computer Engineering","Engineering"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language","label":"Dc Language","values":["en"]},{"key":"dc:rights","label":"Dc Rights","values":["<p>Copyright is held by the author. User is responsible for all copyright compliance.</p>"]},{"key":"dc:rights.holder","label":"Dc Rights Holder","values":["Saba Bakhshi Khayani"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["https://digitalcommons.du.edu/etd/49"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["This thesis presents the development of three different methods for body joint angle measurement using wearable sensors. Continuous monitoring of patients' movements and activities has recently become one of the active research areas in the field of body sensor network and telehealth monitoring. For many medical and rehabilitation applications, a continuous monitor of the patients' daily activities at home without visiting the hospital is desirable. This type of monitoring is beneficial for the therapists and physicians as it does not require patients' physical presence. Traditionally, measuring the range of motion (ROM) is performed in hospitals by utilizing standard tools such as a goniometer. This method needs to be fulfilled by a physiotherapist in the hospital and requires great deal of overhead. Thus, a remote sensing technique for monitoring the progress of body joint flexion during regular daily life activities becomes very beneficial. The main focus of this thesis is on developing different methods for sensing body joint angle, although we developed some mechanisms for transmitting measurements from patient's side to a remote server at the hospital. The first method for measuring the joint angle- specifically the knee joint- is based on an encoder attached to a brace. The second method is performed by utilizing a wearable cloth with flex-sensors. In the third method, inertial measurement units (IMUs) are employed to measure the desired joint angle. We conducted several experiments to compare the feasibility and accuracy of each method for angle measurement with ground truth measurements. The advantages and disadvantages of each approach are discussed and explained in detail in the assigned section."]},{"key":"dc:description.provenance","label":"Dc Description Provenance","values":["Received from ProQuest"]},{"key":"dc:format","label":"Dc Format","values":["application/pdf"]},{"key":"dc:format.extent","label":"Dc Format Extent","values":["76 p."]},{"key":"dc:title","label":"Title","values":["Development of Wearable Sensors for Body Joint Angle Measurement"]}]}],"canonical_facts":{"dc:contributor":["Mohammad H. Mahoor, Ph.D."],"dc:creator":["Bakhshi Khayani, Saba"],"dc:date.available":["2001-01-01T08:00:00Z"],"dc:date.copyright":["2011-06-01T07:00:00Z"],"dc:date.created":["2011-06-01T07:00:00Z"],"dc:description.abstract":["This thesis presents the development of three different methods for body joint angle measurement using wearable sensors. Continuous monitoring of patients' movements and activities has recently become one of the active research areas in the field of body sensor network and telehealth monitoring. For many medical and rehabilitation applications, a continuous monitor of the patients' daily activities at home without visiting the hospital is desirable. This type of monitoring is beneficial for the therapists and physicians as it does not require patients' physical presence. Traditionally, measuring the range of motion (ROM) is performed in hospitals by utilizing standard tools such as a goniometer. This method needs to be fulfilled by a physiotherapist in the hospital and requires great deal of overhead. Thus, a remote sensing technique for monitoring the progress of body joint flexion during regular daily life activities becomes very beneficial. The main focus of this thesis is on developing different methods for sensing body joint angle, although we developed some mechanisms for transmitting measurements from patient's side to a remote server at the hospital. The first method for measuring the joint angle- specifically the knee joint- is based on an encoder attached to a brace. The second method is performed by utilizing a wearable cloth with flex-sensors. In the third method, inertial measurement units (IMUs) are employed to measure the desired joint angle. We conducted several experiments to compare the feasibility and accuracy of each method for angle measurement with ground truth measurements. The advantages and disadvantages of each approach are discussed and explained in detail in the assigned section."],"dc:description.provenance":["Received from ProQuest"],"dc:format":["application/pdf"],"dc:format.extent":["76 p."],"dc:identifier":["https://digitalcommons.du.edu/etd/49"],"dc:language":["en"],"dc:rights":["<p>Copyright is held by the author. User is responsible for all copyright compliance.</p>"],"dc:rights.holder":["Saba Bakhshi Khayani"],"dc:subject":["Wearable sensors","Range of motion (ROM)","Inertial measurement units (IMUs)","Electrical and Computer Engineering","Engineering"],"dc:title":["Development of Wearable Sensors for Body Joint Angle Measurement"],"thesis:degree_level":["Masters Thesis"],"thesis:degree_name":["M.S."]},"updated_at":"2026-11-19T07:54:59Z"}