{"id":{"repo_id":"denver","oai_identifier":"oai:digitalcommons.du.edu:etd-1364"},"canonical_url":"https://search.ndltd.org/etd/denver/oai:digitalcommons.du.edu:etd-1364","repository":{"repo_id":"denver","name":"University of Denver","base_url":"https://digitalcommons.du.edu/do/oai/"},"display":{"title":"Sequence Detection and Comparative Analysis of the Hv1 and Hv2 Control Regions of Human Mitochondrial DNA by Denaturing High-Performance Liquid Chromatography","abstract":"The objective of this research was the evaluation and forensic validation of Denaturing High-Performance Liquid Chromatography (DHPLC) as a sequencingindependent means of detecting the presence of sequence differences in pair-wise mixtures of non-concordant amplicons of human mitochondrial DNA (mtDNA). The reproducibility and efficacy of DHPLC results, including amplification reproducibility, injection reproducibility, and column-to-column reproducibility were measured, showing negligible assay-to-assay variability. In addition, cross-contamination on the DHPLC columns demonstrated very low level DNA carryover between a high-abundance sample and subsequent zero-volume injections. The accuracy with which DHPLC technology can be used to screen both evidence and control samples in the context of a forensic laboratory was evaluated. This was demonstrated by a number of pair-wise comparisons of each of the forensically relevant amplicons from 95 unrelated individuals in the study, and was in 100% agreement with sequencing data. Thus, DHPLC can be used to detect a diversity of sequence differences (transitions, transversions, insertions and deletions) in the mtDNA D-loop. Accordingly, DHPLC may have utility as a presumptive indicator of mtDNA sequence concordance samples.","abstract_html":"The objective of this research was the evaluation and forensic validation of Denaturing High-Performance Liquid Chromatography (DHPLC) as a sequencingindependent means of detecting the presence of sequence differences in pair-wise mixtures of non-concordant amplicons of human mitochondrial DNA (mtDNA). The reproducibility and efficacy of DHPLC results, including amplification reproducibility, injection reproducibility, and column-to-column reproducibility were measured, showing negligible assay-to-assay variability. In addition, cross-contamination on the DHPLC columns demonstrated very low level DNA carryover between a high-abundance sample and subsequent zero-volume injections. The accuracy with which DHPLC technology can be used to screen both evidence and control samples in the context of a forensic laboratory was evaluated. This was demonstrated by a number of pair-wise comparisons of each of the forensically relevant amplicons from 95 unrelated individuals in the study, and was in 100% agreement with sequencing data. Thus, DHPLC can be used to detect a diversity of sequence differences (transitions, transversions, insertions and deletions) in the mtDNA D-loop. Accordingly, DHPLC may have utility as a presumptive indicator of mtDNA sequence concordance samples.","abstract_has_math":false,"creators":["Lewis, Sarah E."],"institution":null,"degree_name":"M.S.","degree_level":"Masters Thesis","degree_discipline":null,"degree_department":null,"school":null,"contributors":["Phillip B. Danielson, Ph.D.","James Fogleman","Nancy Lorenzon","Davor Balzar"],"advisors":[],"committee_chairs":[],"committee_members":[],"year":null,"date_issued":"","date_published":null,"updated_at":"2026-11-19T07:52:56Z","subjects":["Denaturing High-Performance Liquid Chromatography (DHPLC)","Forensic validation","Human mitochondrial DNA","Biology","Life Sciences"],"languages":["en"],"rights":["<p>Copyright is held by the author. User is responsible for all copyright compliance.</p>","Sarah E. Lewis"],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"https://digitalcommons.du.edu/etd/365","outbound_label":"Repository record","outbound_source":"dc:identifier","record_url":"https://digitalcommons.du.edu/etd/365","record_label":"Repository record","record_kind":"record","record_source":"dc:identifier","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://digitalcommons.du.edu/do/oai/?verb=GetRecord&metadataPrefix=oai_etdms&identifier=oai%3Adigitalcommons.du.edu%3Aetd-1364","prefix":"oai_etdms"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor","label":"Contributor","values":["Phillip B. Danielson, Ph.D.","James Fogleman","Nancy Lorenzon","Davor Balzar"]},{"key":"dc:creator","label":"Author","values":["Lewis, Sarah E."]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.available","label":"Dc Date Available","values":["2001-01-01T08:00:00Z"]},{"key":"dc:date.copyright","label":"Dc Date Copyright","values":["2011-08-01T07:00:00Z"]},{"key":"dc:date.created","label":"Dc Date Created","values":["2011-08-01T07:00:00Z"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Masters Thesis"]},{"key":"thesis:degree_name","label":"Degree Name","values":["M.S."]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Denaturing High-Performance Liquid Chromatography (DHPLC)","Forensic validation","Human mitochondrial DNA","Biology","Life Sciences"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language","label":"Dc Language","values":["en"]},{"key":"dc:rights","label":"Dc Rights","values":["<p>Copyright is held by the author. User is responsible for all copyright compliance.</p>"]},{"key":"dc:rights.holder","label":"Dc Rights Holder","values":["Sarah E. Lewis"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["https://digitalcommons.du.edu/etd/365"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["The objective of this research was the evaluation and forensic validation of Denaturing High-Performance Liquid Chromatography (DHPLC) as a sequencingindependent means of detecting the presence of sequence differences in pair-wise mixtures of non-concordant amplicons of human mitochondrial DNA (mtDNA). The reproducibility and efficacy of DHPLC results, including amplification reproducibility, injection reproducibility, and column-to-column reproducibility were measured, showing negligible assay-to-assay variability. In addition, cross-contamination on the DHPLC columns demonstrated very low level DNA carryover between a high-abundance sample and subsequent zero-volume injections. The accuracy with which DHPLC technology can be used to screen both evidence and control samples in the context of a forensic laboratory was evaluated. This was demonstrated by a number of pair-wise comparisons of each of the forensically relevant amplicons from 95 unrelated individuals in the study, and was in 100% agreement with sequencing data. Thus, DHPLC can be used to detect a diversity of sequence differences (transitions, transversions, insertions and deletions) in the mtDNA D-loop. Accordingly, DHPLC may have utility as a presumptive indicator of mtDNA sequence concordance samples."]},{"key":"dc:description.provenance","label":"Dc Description Provenance","values":["Received from ProQuest"]},{"key":"dc:format","label":"Dc Format","values":["application/pdf"]},{"key":"dc:format.extent","label":"Dc Format Extent","values":["102 p."]},{"key":"dc:title","label":"Title","values":["Sequence Detection and Comparative Analysis of the Hv1 and Hv2 Control Regions of Human Mitochondrial DNA by Denaturing High-Performance Liquid Chromatography"]}]}],"canonical_facts":{"dc:contributor":["Phillip B. Danielson, Ph.D.","James Fogleman","Nancy Lorenzon","Davor Balzar"],"dc:creator":["Lewis, Sarah E."],"dc:date.available":["2001-01-01T08:00:00Z"],"dc:date.copyright":["2011-08-01T07:00:00Z"],"dc:date.created":["2011-08-01T07:00:00Z"],"dc:description.abstract":["The objective of this research was the evaluation and forensic validation of Denaturing High-Performance Liquid Chromatography (DHPLC) as a sequencingindependent means of detecting the presence of sequence differences in pair-wise mixtures of non-concordant amplicons of human mitochondrial DNA (mtDNA). The reproducibility and efficacy of DHPLC results, including amplification reproducibility, injection reproducibility, and column-to-column reproducibility were measured, showing negligible assay-to-assay variability. In addition, cross-contamination on the DHPLC columns demonstrated very low level DNA carryover between a high-abundance sample and subsequent zero-volume injections. The accuracy with which DHPLC technology can be used to screen both evidence and control samples in the context of a forensic laboratory was evaluated. This was demonstrated by a number of pair-wise comparisons of each of the forensically relevant amplicons from 95 unrelated individuals in the study, and was in 100% agreement with sequencing data. Thus, DHPLC can be used to detect a diversity of sequence differences (transitions, transversions, insertions and deletions) in the mtDNA D-loop. Accordingly, DHPLC may have utility as a presumptive indicator of mtDNA sequence concordance samples."],"dc:description.provenance":["Received from ProQuest"],"dc:format":["application/pdf"],"dc:format.extent":["102 p."],"dc:identifier":["https://digitalcommons.du.edu/etd/365"],"dc:language":["en"],"dc:rights":["<p>Copyright is held by the author. User is responsible for all copyright compliance.</p>"],"dc:rights.holder":["Sarah E. Lewis"],"dc:subject":["Denaturing High-Performance Liquid Chromatography (DHPLC)","Forensic validation","Human mitochondrial DNA","Biology","Life Sciences"],"dc:title":["Sequence Detection and Comparative Analysis of the Hv1 and Hv2 Control Regions of Human Mitochondrial DNA by Denaturing High-Performance Liquid Chromatography"],"thesis:degree_level":["Masters Thesis"],"thesis:degree_name":["M.S."]},"updated_at":"2026-11-19T07:52:56Z"}