{"id":{"repo_id":"denver","oai_identifier":"oai:digitalcommons.du.edu:etd-1654"},"canonical_url":"https://search.ndltd.org/etd/denver/oai:digitalcommons.du.edu:etd-1654","repository":{"repo_id":"denver","name":"University of Denver","base_url":"https://digitalcommons.du.edu/do/oai/"},"display":{"title":"Label-Free Biochemical Recognition Using MEMS Resonators for Microarray Technology","abstract":"Highly sensitive biosensors capable of detecting and characterizing smallest quantities of cellular and molecular targets are needed in pharmaceutical and medical diagnostics industries. In this work, the importance of biological target recognition specifically proteins through microarray technologies has been discussed and the most successful tools and techniques have been studied. Moreover, a thermally actuated Micro Electro-Mechanical Systems (MEMS) resonator has been demonstrated and fabricated in this work as an accurate, reliable and low cost biotechnology tool. As a proof of concept, amine to epoxide coupling of octadecylamine to functionalized silicon dioxide surface have been shown through resonator frequency monitoring. The frequency deviation of the sensors implied a meaningful surface coverage after analyte immobilization. Furthermore, X-ray Photoelectron Spectroscopy (XPS) analysis of the devices at different stages of the surface modification supported that the frequency deviations are due to epoxide and octadecylamine attachments. In addition, two surface passivation techniques against non-specific adsorption of avidin have been investigated on silicon surfaces","abstract_html":"Highly sensitive biosensors capable of detecting and characterizing smallest quantities of cellular and molecular targets are needed in pharmaceutical and medical diagnostics industries. In this work, the importance of biological target recognition specifically proteins through microarray technologies has been discussed and the most successful tools and techniques have been studied. Moreover, a thermally actuated Micro Electro-Mechanical Systems (MEMS) resonator has been demonstrated and fabricated in this work as an accurate, reliable and low cost biotechnology tool. As a proof of concept, amine to epoxide coupling of octadecylamine to functionalized silicon dioxide surface have been shown through resonator frequency monitoring. The frequency deviation of the sensors implied a meaningful surface coverage after analyte immobilization. Furthermore, X-ray Photoelectron Spectroscopy (XPS) analysis of the devices at different stages of the surface modification supported that the frequency deviations are due to epoxide and octadecylamine attachments. In addition, two surface passivation techniques against non-specific adsorption of avidin have been investigated on silicon surfaces","abstract_has_math":false,"creators":["Tousifar, Babak"],"institution":null,"degree_name":"M.S.","degree_level":"Masters Thesis","degree_discipline":null,"degree_department":null,"school":null,"contributors":["Siavash Pourkamali Anaraki, Ph.D.","Byron W. Purse, Ph.D.","Corinne Lengsfeld"],"advisors":[],"committee_chairs":[],"committee_members":[],"year":null,"date_issued":"","date_published":null,"updated_at":"2026-11-19T07:53:50Z","subjects":["Label-free biochemical analysis","Medical diagnostics","Microelectromechanical systems","MEMS","Biosensors","Protein microarray technology","Surface modification","Thermally actuated","Resonators","Biomechanical Engineering","Engineering","Mechanical Engineering"],"languages":["en"],"rights":["<p>Copyright is held by the author. User is responsible for all copyright compliance.</p>","Babak Tousifar"],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"https://digitalcommons.du.edu/etd/655","outbound_label":"Repository record","outbound_source":"dc:identifier","record_url":"https://digitalcommons.du.edu/etd/655","record_label":"Repository record","record_kind":"record","record_source":"dc:identifier","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://digitalcommons.du.edu/do/oai/?verb=GetRecord&metadataPrefix=oai_etdms&identifier=oai%3Adigitalcommons.du.edu%3Aetd-1654","prefix":"oai_etdms"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor","label":"Contributor","values":["Siavash Pourkamali Anaraki, Ph.D.","Byron W. Purse, Ph.D.","Corinne Lengsfeld"]},{"key":"dc:creator","label":"Author","values":["Tousifar, Babak"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.available","label":"Dc Date Available","values":["2001-01-01T08:00:00Z"]},{"key":"dc:date.copyright","label":"Dc Date Copyright","values":["2011-01-01T08:00:00Z"]},{"key":"dc:date.created","label":"Dc Date Created","values":["2011-01-01T08:00:00Z"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Masters Thesis"]},{"key":"thesis:degree_name","label":"Degree Name","values":["M.S."]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Label-free biochemical analysis","Medical diagnostics","Microelectromechanical systems","MEMS","Biosensors","Protein microarray technology","Surface modification","Thermally actuated","Resonators","Biomechanical Engineering","Engineering","Mechanical Engineering"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language","label":"Dc Language","values":["en"]},{"key":"dc:rights","label":"Dc Rights","values":["<p>Copyright is held by the author. User is responsible for all copyright compliance.</p>"]},{"key":"dc:rights.holder","label":"Dc Rights Holder","values":["Babak Tousifar"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["https://digitalcommons.du.edu/etd/655"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["Highly sensitive biosensors capable of detecting and characterizing smallest quantities of cellular and molecular targets are needed in pharmaceutical and medical diagnostics industries. In this work, the importance of biological target recognition specifically proteins through microarray technologies has been discussed and the most successful tools and techniques have been studied. Moreover, a thermally actuated Micro Electro-Mechanical Systems (MEMS) resonator has been demonstrated and fabricated in this work as an accurate, reliable and low cost biotechnology tool. As a proof of concept, amine to epoxide coupling of octadecylamine to functionalized silicon dioxide surface have been shown through resonator frequency monitoring. The frequency deviation of the sensors implied a meaningful surface coverage after analyte immobilization. Furthermore, X-ray Photoelectron Spectroscopy (XPS) analysis of the devices at different stages of the surface modification supported that the frequency deviations are due to epoxide and octadecylamine attachments. In addition, two surface passivation techniques against non-specific adsorption of avidin have been investigated on silicon surfaces"]},{"key":"dc:description.provenance","label":"Dc Description Provenance","values":["Received from ProQuest"]},{"key":"dc:format","label":"Dc Format","values":["application/pdf"]},{"key":"dc:format.extent","label":"Dc Format Extent","values":["87 p."]},{"key":"dc:title","label":"Title","values":["Label-Free Biochemical Recognition Using MEMS Resonators for Microarray Technology"]}]}],"canonical_facts":{"dc:contributor":["Siavash Pourkamali Anaraki, Ph.D.","Byron W. Purse, Ph.D.","Corinne Lengsfeld"],"dc:creator":["Tousifar, Babak"],"dc:date.available":["2001-01-01T08:00:00Z"],"dc:date.copyright":["2011-01-01T08:00:00Z"],"dc:date.created":["2011-01-01T08:00:00Z"],"dc:description.abstract":["Highly sensitive biosensors capable of detecting and characterizing smallest quantities of cellular and molecular targets are needed in pharmaceutical and medical diagnostics industries. In this work, the importance of biological target recognition specifically proteins through microarray technologies has been discussed and the most successful tools and techniques have been studied. Moreover, a thermally actuated Micro Electro-Mechanical Systems (MEMS) resonator has been demonstrated and fabricated in this work as an accurate, reliable and low cost biotechnology tool. As a proof of concept, amine to epoxide coupling of octadecylamine to functionalized silicon dioxide surface have been shown through resonator frequency monitoring. The frequency deviation of the sensors implied a meaningful surface coverage after analyte immobilization. Furthermore, X-ray Photoelectron Spectroscopy (XPS) analysis of the devices at different stages of the surface modification supported that the frequency deviations are due to epoxide and octadecylamine attachments. In addition, two surface passivation techniques against non-specific adsorption of avidin have been investigated on silicon surfaces"],"dc:description.provenance":["Received from ProQuest"],"dc:format":["application/pdf"],"dc:format.extent":["87 p."],"dc:identifier":["https://digitalcommons.du.edu/etd/655"],"dc:language":["en"],"dc:rights":["<p>Copyright is held by the author. User is responsible for all copyright compliance.</p>"],"dc:rights.holder":["Babak Tousifar"],"dc:subject":["Label-free biochemical analysis","Medical diagnostics","Microelectromechanical systems","MEMS","Biosensors","Protein microarray technology","Surface modification","Thermally actuated","Resonators","Biomechanical Engineering","Engineering","Mechanical Engineering"],"dc:title":["Label-Free Biochemical Recognition Using MEMS Resonators for Microarray Technology"],"thesis:degree_level":["Masters Thesis"],"thesis:degree_name":["M.S."]},"updated_at":"2026-11-19T07:53:50Z"}