{"id":{"repo_id":"denver","oai_identifier":"oai:digitalcommons.du.edu:etd-3042"},"canonical_url":"https://search.ndltd.org/etd/denver/oai:digitalcommons.du.edu:etd-3042","repository":{"repo_id":"denver","name":"University of Denver","base_url":"https://digitalcommons.du.edu/do/oai/"},"display":{"title":"Revision Total Hip Femoral Stem Micromotion and Statistical Shape Modeling of the Knee","abstract":"The first purpose of this thesis was to compare the amount of micromotion seen in the femoral stem in a revision total hip arthroplasty between simple loading conditions and loading conditions derived from activities of daily living, through the use of experimental and computational methods. The amount of micromotion at the bone-implant interface was larger for activities of daily living, with ranges of 200μm more than the largest simple loading conditions. The second purpose of this thesis was to compare measurements of accuracy in a statistical shape model between individual bone and joint-level models, specifically for the knee. Using computational methods, this study suggested that individual bone models produced lower amounts of errors in accuracy measurements than joint-level models, specifically when looking at similar number of modes of variation in each model. These two studies present research in the development of the next generation of implants in total joint arthroplasties.","abstract_html":"The first purpose of this thesis was to compare the amount of micromotion seen in the femoral stem in a revision total hip arthroplasty between simple loading conditions and loading conditions derived from activities of daily living, through the use of experimental and computational methods. The amount of micromotion at the bone-implant interface was larger for activities of daily living, with ranges of 200μm more than the largest simple loading conditions. The second purpose of this thesis was to compare measurements of accuracy in a statistical shape model between individual bone and joint-level models, specifically for the knee. Using computational methods, this study suggested that individual bone models produced lower amounts of errors in accuracy measurements than joint-level models, specifically when looking at similar number of modes of variation in each model. These two studies present research in the development of the next generation of implants in total joint arthroplasties.","abstract_has_math":false,"creators":["Fugit, William"],"institution":null,"degree_name":"M.S.","degree_level":"Masters Thesis","degree_discipline":null,"degree_department":null,"school":null,"contributors":["Chadd W. Clary","Peter J. Laz","Dinah Loerke"],"advisors":[],"committee_chairs":[],"committee_members":[],"year":null,"date_issued":"","date_published":null,"updated_at":"2026-11-19T07:54:59Z","subjects":["Micromotion","Orthopaedics","Revision total hip arthroplasty","Statistical shape model","Total joint replacement","Total knee arthroplasty","Biological Engineering","Biomechanics and Biotransport","Biomedical Engineering and Bioengineering","Engineering"],"languages":["en"],"rights":["<p>Copyright is held by the author. User is responsible for all copyright compliance.</p>","William Fugit"],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"https://digitalcommons.du.edu/etd/2050","outbound_label":"Repository record","outbound_source":"dc:identifier","record_url":"https://digitalcommons.du.edu/etd/2050","record_label":"Repository record","record_kind":"record","record_source":"dc:identifier","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://digitalcommons.du.edu/do/oai/?verb=GetRecord&metadataPrefix=oai_etdms&identifier=oai%3Adigitalcommons.du.edu%3Aetd-3042","prefix":"oai_etdms"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor","label":"Contributor","values":["Chadd W. Clary","Peter J. Laz","Dinah Loerke"]},{"key":"dc:creator","label":"Author","values":["Fugit, William"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.available","label":"Dc Date Available","values":["2022-08-16T07:00:00Z"]},{"key":"dc:date.copyright","label":"Dc Date Copyright","values":["2022-01-01T08:00:00Z"]},{"key":"dc:date.created","label":"Dc Date Created","values":["2022-01-01T08:00:00Z"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Masters Thesis"]},{"key":"thesis:degree_name","label":"Degree Name","values":["M.S."]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Micromotion","Orthopaedics","Revision total hip arthroplasty","Statistical shape model","Total joint replacement","Total knee arthroplasty","Biological Engineering","Biomechanics and Biotransport","Biomedical Engineering and Bioengineering","Engineering"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language","label":"Dc Language","values":["en"]},{"key":"dc:rights","label":"Dc Rights","values":["<p>Copyright is held by the author. User is responsible for all copyright compliance.</p>"]},{"key":"dc:rights.holder","label":"Dc Rights Holder","values":["William Fugit"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["https://digitalcommons.du.edu/etd/2050"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["The first purpose of this thesis was to compare the amount of micromotion seen in the femoral stem in a revision total hip arthroplasty between simple loading conditions and loading conditions derived from activities of daily living, through the use of experimental and computational methods. The amount of micromotion at the bone-implant interface was larger for activities of daily living, with ranges of 200μm more than the largest simple loading conditions. The second purpose of this thesis was to compare measurements of accuracy in a statistical shape model between individual bone and joint-level models, specifically for the knee. Using computational methods, this study suggested that individual bone models produced lower amounts of errors in accuracy measurements than joint-level models, specifically when looking at similar number of modes of variation in each model. These two studies present research in the development of the next generation of implants in total joint arthroplasties."]},{"key":"dc:description.provenance","label":"Dc Description Provenance","values":["Received from ProQuest"]},{"key":"dc:format","label":"Dc Format","values":["application/pdf"]},{"key":"dc:format.extent","label":"Dc Format Extent","values":["93 pgs"]},{"key":"dc:title","label":"Title","values":["Revision Total Hip Femoral Stem Micromotion and Statistical Shape Modeling of the Knee"]}]}],"canonical_facts":{"dc:contributor":["Chadd W. Clary","Peter J. Laz","Dinah Loerke"],"dc:creator":["Fugit, William"],"dc:date.available":["2022-08-16T07:00:00Z"],"dc:date.copyright":["2022-01-01T08:00:00Z"],"dc:date.created":["2022-01-01T08:00:00Z"],"dc:description.abstract":["The first purpose of this thesis was to compare the amount of micromotion seen in the femoral stem in a revision total hip arthroplasty between simple loading conditions and loading conditions derived from activities of daily living, through the use of experimental and computational methods. The amount of micromotion at the bone-implant interface was larger for activities of daily living, with ranges of 200μm more than the largest simple loading conditions. The second purpose of this thesis was to compare measurements of accuracy in a statistical shape model between individual bone and joint-level models, specifically for the knee. Using computational methods, this study suggested that individual bone models produced lower amounts of errors in accuracy measurements than joint-level models, specifically when looking at similar number of modes of variation in each model. These two studies present research in the development of the next generation of implants in total joint arthroplasties."],"dc:description.provenance":["Received from ProQuest"],"dc:format":["application/pdf"],"dc:format.extent":["93 pgs"],"dc:identifier":["https://digitalcommons.du.edu/etd/2050"],"dc:language":["en"],"dc:rights":["<p>Copyright is held by the author. User is responsible for all copyright compliance.</p>"],"dc:rights.holder":["William Fugit"],"dc:subject":["Micromotion","Orthopaedics","Revision total hip arthroplasty","Statistical shape model","Total joint replacement","Total knee arthroplasty","Biological Engineering","Biomechanics and Biotransport","Biomedical Engineering and Bioengineering","Engineering"],"dc:title":["Revision Total Hip Femoral Stem Micromotion and Statistical Shape Modeling of the Knee"],"thesis:degree_level":["Masters Thesis"],"thesis:degree_name":["M.S."]},"updated_at":"2026-11-19T07:54:59Z"}