{"id":{"repo_id":"denver","oai_identifier":"oai:digitalcommons.du.edu:etd-3136"},"canonical_url":"https://search.ndltd.org/etd/denver/oai:digitalcommons.du.edu:etd-3136","repository":{"repo_id":"denver","name":"University of Denver","base_url":"https://digitalcommons.du.edu/do/oai/"},"display":{"title":"Contact Simulation for Evaluating Patient Specific Surgical Guide Stability","abstract":"This study proposes a novel computational method to quantify guide stability for Patient Specific Instrumentation (PSI) guides. A finite element contact model was used to analyze the final position of PSI guides on a femur across a range of loading parameters representing forces applied by a surgeon during operative use. Separate segmentation methods were used for the guide and bone geometry to represent differences between segmentation and actual patient geometry. The region of loading parameters over which the guide exhibited a consistent final position was measured and reported as Guide Stability Score. The model was verified using cadaver specimens for which 3D printed PSI guides were applied to the knee using similar variations in guide loading. A strong correlation was found between the Guide Stability Score and the variance seen in the lab (R2 = 0.84), suggesting the model provides a useful tool for the evaluation of PSI guide stability.","abstract_html":"This study proposes a novel computational method to quantify guide stability for Patient Specific Instrumentation (PSI) guides. A finite element contact model was used to analyze the final position of PSI guides on a femur across a range of loading parameters representing forces applied by a surgeon during operative use. Separate segmentation methods were used for the guide and bone geometry to represent differences between segmentation and actual patient geometry. The region of loading parameters over which the guide exhibited a consistent final position was measured and reported as Guide Stability Score. The model was verified using cadaver specimens for which 3D printed PSI guides were applied to the knee using similar variations in guide loading. A strong correlation was found between the Guide Stability Score and the variance seen in the lab (R2 = 0.84), suggesting the model provides a useful tool for the evaluation of PSI guide stability.","abstract_has_math":false,"creators":["Nierste, Vincent"],"institution":null,"degree_name":"M.S.","degree_level":"Masters Thesis","degree_discipline":null,"degree_department":null,"school":null,"contributors":["Chadd Clary","Paul Rullkoeter","Mei Yin"],"advisors":[],"committee_chairs":[],"committee_members":[],"year":null,"date_issued":"","date_published":null,"updated_at":"2026-11-19T07:53:43Z","subjects":["Contact simulation","Patient specific guide","Total knee arthoplasty","Biomechanical Engineering","Biomedical Devices and Instrumentation","Mechanical Engineering"],"languages":["en"],"rights":["<p>Copyright is held by the author. User is responsible for all copyright compliance.</p>","Vincent Nierste"],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"https://digitalcommons.du.edu/etd/2147","outbound_label":"Repository record","outbound_source":"dc:identifier","record_url":"https://digitalcommons.du.edu/etd/2147","record_label":"Repository record","record_kind":"record","record_source":"dc:identifier","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://digitalcommons.du.edu/do/oai/?verb=GetRecord&metadataPrefix=oai_etdms&identifier=oai%3Adigitalcommons.du.edu%3Aetd-3136","prefix":"oai_etdms"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor","label":"Contributor","values":["Chadd Clary","Paul Rullkoeter","Mei Yin"]},{"key":"dc:creator","label":"Author","values":["Nierste, Vincent"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.copyright","label":"Dc Date Copyright","values":["2022-01-01T08:00:00Z"]},{"key":"dc:date.created","label":"Dc Date Created","values":["2022-01-01T08:00:00Z"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Masters Thesis"]},{"key":"thesis:degree_name","label":"Degree Name","values":["M.S."]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Contact simulation","Patient specific guide","Total knee arthoplasty","Biomechanical Engineering","Biomedical Devices and Instrumentation","Mechanical Engineering"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language","label":"Dc Language","values":["en"]},{"key":"dc:rights","label":"Dc Rights","values":["<p>Copyright is held by the author. User is responsible for all copyright compliance.</p>"]},{"key":"dc:rights.holder","label":"Dc Rights Holder","values":["Vincent Nierste"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["https://digitalcommons.du.edu/etd/2147"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["This study proposes a novel computational method to quantify guide stability for Patient Specific Instrumentation (PSI) guides. A finite element contact model was used to analyze the final position of PSI guides on a femur across a range of loading parameters representing forces applied by a surgeon during operative use. Separate segmentation methods were used for the guide and bone geometry to represent differences between segmentation and actual patient geometry. The region of loading parameters over which the guide exhibited a consistent final position was measured and reported as Guide Stability Score. The model was verified using cadaver specimens for which 3D printed PSI guides were applied to the knee using similar variations in guide loading. A strong correlation was found between the Guide Stability Score and the variance seen in the lab (R2 = 0.84), suggesting the model provides a useful tool for the evaluation of PSI guide stability."]},{"key":"dc:description.provenance","label":"Dc Description Provenance","values":["Received from ProQuest"]},{"key":"dc:format","label":"Dc Format","values":["application/pdf"]},{"key":"dc:format.extent","label":"Dc Format Extent","values":["47 pgs"]},{"key":"dc:title","label":"Title","values":["Contact Simulation for Evaluating Patient Specific Surgical Guide Stability"]}]}],"canonical_facts":{"dc:contributor":["Chadd Clary","Paul Rullkoeter","Mei Yin"],"dc:creator":["Nierste, Vincent"],"dc:date.copyright":["2022-01-01T08:00:00Z"],"dc:date.created":["2022-01-01T08:00:00Z"],"dc:description.abstract":["This study proposes a novel computational method to quantify guide stability for Patient Specific Instrumentation (PSI) guides. A finite element contact model was used to analyze the final position of PSI guides on a femur across a range of loading parameters representing forces applied by a surgeon during operative use. Separate segmentation methods were used for the guide and bone geometry to represent differences between segmentation and actual patient geometry. The region of loading parameters over which the guide exhibited a consistent final position was measured and reported as Guide Stability Score. The model was verified using cadaver specimens for which 3D printed PSI guides were applied to the knee using similar variations in guide loading. A strong correlation was found between the Guide Stability Score and the variance seen in the lab (R2 = 0.84), suggesting the model provides a useful tool for the evaluation of PSI guide stability."],"dc:description.provenance":["Received from ProQuest"],"dc:format":["application/pdf"],"dc:format.extent":["47 pgs"],"dc:identifier":["https://digitalcommons.du.edu/etd/2147"],"dc:language":["en"],"dc:rights":["<p>Copyright is held by the author. User is responsible for all copyright compliance.</p>"],"dc:rights.holder":["Vincent Nierste"],"dc:subject":["Contact simulation","Patient specific guide","Total knee arthoplasty","Biomechanical Engineering","Biomedical Devices and Instrumentation","Mechanical Engineering"],"dc:title":["Contact Simulation for Evaluating Patient Specific Surgical Guide Stability"],"thesis:degree_level":["Masters Thesis"],"thesis:degree_name":["M.S."]},"updated_at":"2026-11-19T07:53:43Z"}