{"id":{"repo_id":"denver","oai_identifier":"oai:digitalcommons.du.edu:etd-3180"},"canonical_url":"https://search.ndltd.org/etd/denver/oai:digitalcommons.du.edu:etd-3180","repository":{"repo_id":"denver","name":"University of Denver","base_url":"https://digitalcommons.du.edu/do/oai/"},"display":{"title":"Passive Liquid Draw Using Micro Needles","abstract":"The blood draw portion of an in-home blood testing system was investigated with focus on ease of use, pain reduction, flow rate, and the total volume of blood drawn. Traditional style stainless steel hypodermic needles were used in order to investigate the effects of size, viscosity, surface tension, the presence of a porous medium, clogging by tissue, and surface coatings on flow rate through needles in the presence of simulated human capillary bed blood pressure. Non-coring point style needles were found to operate the best in terms of resistance to clogging. Surface effects were found in as large as 26 gauge (0.464 mm OD) needles at low pressure, and were prominent in 31 gauge (0.261 mm OD) and 33 gauge (0.210 mm OD) needles at high pressure. An array of 4-6 needles was conceived to enhance system reliability in light of complicating factors such as viscosity, random obstruction by porous medium, and surface tension.","abstract_html":"The blood draw portion of an in-home blood testing system was investigated with focus on ease of use, pain reduction, flow rate, and the total volume of blood drawn. Traditional style stainless steel hypodermic needles were used in order to investigate the effects of size, viscosity, surface tension, the presence of a porous medium, clogging by tissue, and surface coatings on flow rate through needles in the presence of simulated human capillary bed blood pressure. Non-coring point style needles were found to operate the best in terms of resistance to clogging. Surface effects were found in as large as 26 gauge (0.464 mm OD) needles at low pressure, and were prominent in 31 gauge (0.261 mm OD) and 33 gauge (0.210 mm OD) needles at high pressure. An array of 4-6 needles was conceived to enhance system reliability in light of complicating factors such as viscosity, random obstruction by porous medium, and surface tension.","abstract_has_math":false,"creators":["Huber, Nathan M."],"institution":null,"degree_name":"M.S.","degree_level":"Masters Thesis","degree_discipline":null,"degree_department":null,"school":null,"contributors":["Corinne Lengsfeld"],"advisors":[],"committee_chairs":[],"committee_members":[],"year":null,"date_issued":"","date_published":null,"updated_at":"2026-11-19T07:54:41Z","subjects":["Blood test","Needle design","Hypodermic needles","Biomedical Devices and Instrumentation","Biomedical Engineering and Bioengineering","Engineering"],"languages":["en"],"rights":["<p>Copyright is held by the author. Permanently suppressed.</p>","Nathan M. Huber"],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"https://digitalcommons.du.edu/etd/2188","outbound_label":"Repository record","outbound_source":"dc:identifier","record_url":"https://digitalcommons.du.edu/etd/2188","record_label":"Repository record","record_kind":"record","record_source":"dc:identifier","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://digitalcommons.du.edu/do/oai/?verb=GetRecord&metadataPrefix=oai_etdms&identifier=oai%3Adigitalcommons.du.edu%3Aetd-3180","prefix":"oai_etdms"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor","label":"Contributor","values":["Corinne Lengsfeld"]},{"key":"dc:creator","label":"Author","values":["Huber, Nathan M."]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.copyright","label":"Dc Date Copyright","values":["2015-06-01T07:00:00Z"]},{"key":"dc:date.created","label":"Dc Date Created","values":["2015-06-01T07:00:00Z"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Masters Thesis"]},{"key":"thesis:degree_name","label":"Degree Name","values":["M.S."]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Blood test","Needle design","Hypodermic needles","Biomedical Devices and Instrumentation","Biomedical Engineering and Bioengineering","Engineering"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language","label":"Dc Language","values":["en"]},{"key":"dc:rights","label":"Dc Rights","values":["<p>Copyright is held by the author. Permanently suppressed.</p>"]},{"key":"dc:rights.holder","label":"Dc Rights Holder","values":["Nathan M. Huber"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["https://digitalcommons.du.edu/etd/2188"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["The blood draw portion of an in-home blood testing system was investigated with focus on ease of use, pain reduction, flow rate, and the total volume of blood drawn. Traditional style stainless steel hypodermic needles were used in order to investigate the effects of size, viscosity, surface tension, the presence of a porous medium, clogging by tissue, and surface coatings on flow rate through needles in the presence of simulated human capillary bed blood pressure. Non-coring point style needles were found to operate the best in terms of resistance to clogging. Surface effects were found in as large as 26 gauge (0.464 mm OD) needles at low pressure, and were prominent in 31 gauge (0.261 mm OD) and 33 gauge (0.210 mm OD) needles at high pressure. An array of 4-6 needles was conceived to enhance system reliability in light of complicating factors such as viscosity, random obstruction by porous medium, and surface tension."]},{"key":"dc:description.provenance","label":"Dc Description Provenance","values":["Received from author"]},{"key":"dc:format","label":"Dc Format","values":["application/pdf"]},{"key":"dc:format.extent","label":"Dc Format Extent","values":["89 pgs"]},{"key":"dc:title","label":"Title","values":["Passive Liquid Draw Using Micro Needles"]}]}],"canonical_facts":{"dc:contributor":["Corinne Lengsfeld"],"dc:creator":["Huber, Nathan M."],"dc:date.copyright":["2015-06-01T07:00:00Z"],"dc:date.created":["2015-06-01T07:00:00Z"],"dc:description.abstract":["The blood draw portion of an in-home blood testing system was investigated with focus on ease of use, pain reduction, flow rate, and the total volume of blood drawn. Traditional style stainless steel hypodermic needles were used in order to investigate the effects of size, viscosity, surface tension, the presence of a porous medium, clogging by tissue, and surface coatings on flow rate through needles in the presence of simulated human capillary bed blood pressure. Non-coring point style needles were found to operate the best in terms of resistance to clogging. Surface effects were found in as large as 26 gauge (0.464 mm OD) needles at low pressure, and were prominent in 31 gauge (0.261 mm OD) and 33 gauge (0.210 mm OD) needles at high pressure. An array of 4-6 needles was conceived to enhance system reliability in light of complicating factors such as viscosity, random obstruction by porous medium, and surface tension."],"dc:description.provenance":["Received from author"],"dc:format":["application/pdf"],"dc:format.extent":["89 pgs"],"dc:identifier":["https://digitalcommons.du.edu/etd/2188"],"dc:language":["en"],"dc:rights":["<p>Copyright is held by the author. Permanently suppressed.</p>"],"dc:rights.holder":["Nathan M. Huber"],"dc:subject":["Blood test","Needle design","Hypodermic needles","Biomedical Devices and Instrumentation","Biomedical Engineering and Bioengineering","Engineering"],"dc:title":["Passive Liquid Draw Using Micro Needles"],"thesis:degree_level":["Masters Thesis"],"thesis:degree_name":["M.S."]},"updated_at":"2026-11-19T07:54:41Z"}