{"id":{"repo_id":"denver","oai_identifier":"oai:digitalcommons.du.edu:etd-3764"},"canonical_url":"https://search.ndltd.org/etd/denver/oai:digitalcommons.du.edu:etd-3764","repository":{"repo_id":"denver","name":"University of Denver","base_url":"https://digitalcommons.du.edu/do/oai/"},"display":{"title":"Development, Optimization, and Validation of a High-Sensitivity Capillary Zone Electrophoresis System for Bioanalytical Applications","abstract":"Capillary zone electrophoresis (CZE) is a powerful analytical technique widely used for biomolecular separation due to its high resolution, efficiency, and sensitivity. This report presents the development and validation of a novel CZE system designed to improve modularity, reproducibility, and operational efficiency. The system integrates a laser-induced fluorescence (LIF) detection method with a 488 nm laser, enhanced fluid control through a negative pressure system, and a user-friendly GUI for automated operation and data acquisition. Performance verification included pressure stability tests, fluorescence accuracy assessments, and electrophoretic reproducibility studies. Comparative analysis with a previous CZE iteration confirmed improved baseline stability, peak resolution, and modular integration, while maintaining comparable sensitivity. A vacuum pump vibration dampener was also developed to minimize interference. The new CZE system addresses key limitations of earlier models, enhancing usability and adaptability for biomedical research applications, particularly in neurodegenerative disease diagnostics and biomarker discovery.","abstract_html":"Capillary zone electrophoresis (CZE) is a powerful analytical technique widely used for biomolecular separation due to its high resolution, efficiency, and sensitivity. This report presents the development and validation of a novel CZE system designed to improve modularity, reproducibility, and operational efficiency. The system integrates a laser-induced fluorescence (LIF) detection method with a 488 nm laser, enhanced fluid control through a negative pressure system, and a user-friendly GUI for automated operation and data acquisition. Performance verification included pressure stability tests, fluorescence accuracy assessments, and electrophoretic reproducibility studies. Comparative analysis with a previous CZE iteration confirmed improved baseline stability, peak resolution, and modular integration, while maintaining comparable sensitivity. A vacuum pump vibration dampener was also developed to minimize interference. The new CZE system addresses key limitations of earlier models, enhancing usability and adaptability for biomedical research applications, particularly in neurodegenerative disease diagnostics and biomarker discovery.","abstract_has_math":false,"creators":["Mena, Aaron I."],"institution":null,"degree_name":"M.S. in Bioengineering","degree_level":"Masters Thesis","degree_discipline":null,"degree_department":null,"school":null,"contributors":["Daniel Paredes","Casey Myers","Goncalo Martins","Mohammad Matin"],"advisors":[],"committee_chairs":[],"committee_members":[],"year":null,"date_issued":"","date_published":null,"updated_at":"2026-11-19T07:55:07Z","subjects":["Diagnostics","Electrophoresis","Fluorescence","Polyamines","Analytical Chemistry","Biochemistry","Biomedical Devices and Instrumentation","Biomedical Engineering and Bioengineering"],"languages":["English (eng)"],"rights":["<p>Copyright is held by the author. User is responsible for all copyright compliance.</p>","Aaron I. Mena"],"rights_urls":[],"identifier_entries":[{"key":"dc:identifier","label":"Identifier","values":["ETDCRP.2025.35","<a href=\"https://doi.org/10.56902/ETDCRP.2025.35\">https://doi.org/10.56902/ETDCRP.2025.35</a>","https://digitalcommons.du.edu/etd/2532"],"render_values":[{"text":"ETDCRP.2025.35","href":null,"code":true},{"text":"<a href=\"https://doi.org/10.56902/ETDCRP.2025.35\">https://doi.org/10.56902/ETDCRP.2025.35</a>","href":"https://doi.org/10.56902/ETDCRP.2025.35\">https://doi.org/10.56902/ETDCRP.2025.35</a>","code":true},{"text":"https://digitalcommons.du.edu/etd/2532","href":"https://digitalcommons.du.edu/etd/2532","code":true}]}],"person_identifier_entries":[]},"links":{"outbound_url":"https://doi.org/10.56902/ETDCRP.2025.35","outbound_label":"DOI","outbound_source":"dc:identifier","record_url":"https://doi.org/10.56902/ETDCRP.2025.35","record_label":"Repository record","record_kind":"doi","record_source":"dc:identifier","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://digitalcommons.du.edu/do/oai/?verb=GetRecord&metadataPrefix=oai_etdms&identifier=oai%3Adigitalcommons.du.edu%3Aetd-3764","prefix":"oai_etdms"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor","label":"Contributor","values":["Daniel Paredes","Casey Myers","Goncalo Martins","Mohammad Matin"]},{"key":"dc:creator","label":"Author","values":["Mena, Aaron I."]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.copyright","label":"Dc Date Copyright","values":["2025-03-01T08:00:00Z"]},{"key":"dc:date.created","label":"Dc Date Created","values":["2025-03-22T07:00:00Z"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Masters Thesis"]},{"key":"thesis:degree_name","label":"Degree Name","values":["M.S. in Bioengineering"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Diagnostics","Electrophoresis","Fluorescence","Polyamines","Analytical Chemistry","Biochemistry","Biomedical Devices and Instrumentation","Biomedical Engineering and Bioengineering"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language","label":"Dc Language","values":["English (eng)"]},{"key":"dc:rights","label":"Dc Rights","values":["<p>Copyright is held by the author. User is responsible for all copyright compliance.</p>"]},{"key":"dc:rights.holder","label":"Dc Rights Holder","values":["Aaron I. Mena"]},{"key":"dc:rights.license","label":"Dc Rights License","values":["all_rights_reserved"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["ETDCRP.2025.35","https://doi.org/10.56902/ETDCRP.2025.35","<a href=\"https://doi.org/10.56902/ETDCRP.2025.35\">https://doi.org/10.56902/ETDCRP.2025.35</a>","https://digitalcommons.du.edu/etd/2532"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["Capillary zone electrophoresis (CZE) is a powerful analytical technique widely used for biomolecular separation due to its high resolution, efficiency, and sensitivity. This report presents the development and validation of a novel CZE system designed to improve modularity, reproducibility, and operational efficiency. The system integrates a laser-induced fluorescence (LIF) detection method with a 488 nm laser, enhanced fluid control through a negative pressure system, and a user-friendly GUI for automated operation and data acquisition. Performance verification included pressure stability tests, fluorescence accuracy assessments, and electrophoretic reproducibility studies. Comparative analysis with a previous CZE iteration confirmed improved baseline stability, peak resolution, and modular integration, while maintaining comparable sensitivity. A vacuum pump vibration dampener was also developed to minimize interference. The new CZE system addresses key limitations of earlier models, enhancing usability and adaptability for biomedical research applications, particularly in neurodegenerative disease diagnostics and biomarker discovery."]},{"key":"dc:description.provenance","label":"Dc Description Provenance","values":["Received from author"]},{"key":"dc:format","label":"Dc Format","values":["application/pdf"]},{"key":"dc:format.extent","label":"Dc Format Extent","values":["197 pgs","6.7 MB"]},{"key":"dc:title","label":"Title","values":["Development, Optimization, and Validation of a High-Sensitivity Capillary Zone Electrophoresis System for Bioanalytical Applications"]}]}],"canonical_facts":{"dc:contributor":["Daniel Paredes","Casey Myers","Goncalo Martins","Mohammad Matin"],"dc:creator":["Mena, Aaron I."],"dc:date.copyright":["2025-03-01T08:00:00Z"],"dc:date.created":["2025-03-22T07:00:00Z"],"dc:description.abstract":["Capillary zone electrophoresis (CZE) is a powerful analytical technique widely used for biomolecular separation due to its high resolution, efficiency, and sensitivity. This report presents the development and validation of a novel CZE system designed to improve modularity, reproducibility, and operational efficiency. The system integrates a laser-induced fluorescence (LIF) detection method with a 488 nm laser, enhanced fluid control through a negative pressure system, and a user-friendly GUI for automated operation and data acquisition. Performance verification included pressure stability tests, fluorescence accuracy assessments, and electrophoretic reproducibility studies. Comparative analysis with a previous CZE iteration confirmed improved baseline stability, peak resolution, and modular integration, while maintaining comparable sensitivity. A vacuum pump vibration dampener was also developed to minimize interference. The new CZE system addresses key limitations of earlier models, enhancing usability and adaptability for biomedical research applications, particularly in neurodegenerative disease diagnostics and biomarker discovery."],"dc:description.provenance":["Received from author"],"dc:format":["application/pdf"],"dc:format.extent":["197 pgs","6.7 MB"],"dc:identifier":["ETDCRP.2025.35","https://doi.org/10.56902/ETDCRP.2025.35","<a href=\"https://doi.org/10.56902/ETDCRP.2025.35\">https://doi.org/10.56902/ETDCRP.2025.35</a>","https://digitalcommons.du.edu/etd/2532"],"dc:language":["English (eng)"],"dc:rights":["<p>Copyright is held by the author. User is responsible for all copyright compliance.</p>"],"dc:rights.holder":["Aaron I. Mena"],"dc:rights.license":["all_rights_reserved"],"dc:subject":["Diagnostics","Electrophoresis","Fluorescence","Polyamines","Analytical Chemistry","Biochemistry","Biomedical Devices and Instrumentation","Biomedical Engineering and Bioengineering"],"dc:title":["Development, Optimization, and Validation of a High-Sensitivity Capillary Zone Electrophoresis System for Bioanalytical Applications"],"thesis:degree_level":["Masters Thesis"],"thesis:degree_name":["M.S. in Bioengineering"]},"updated_at":"2026-11-19T07:55:07Z"}