{"id":{"repo_id":"denver","oai_identifier":"oai:digitalcommons.du.edu:etd-3911"},"canonical_url":"https://search.ndltd.org/etd/denver/oai:digitalcommons.du.edu:etd-3911","repository":{"repo_id":"denver","name":"University of Denver","base_url":"https://digitalcommons.du.edu/do/oai/"},"display":{"title":"Experimental and Computational Characterization of Transcatheter Aortic Valve Mechanics Using Digital Image Correlation and Finite Element Modeling","abstract":"Young, low-risk patients undergoing transcatheter heart valve replacement procedures have longer life expectancies that demand valves with superior durability, functionality, and long-term performance. Two transcatheter aortic valves, the Evolut FX and ACURATE neo2, were analyzed in finite element and digital image correlation experiments to determine their mechanical responses to normotensive and hypertensive conditions. Digital image correlation was used to evaluate the strain and displacement fields across the valve leaflets and as input data to conduct material parameter optimization. Finite element analyses were used to indicate the stress fields experienced by the valves. The maximum in-plane principal stress at the commissure level for Evolut FX was 0.53 MPa and 0.54 MPa for circular and elliptical configurations, respectively, under hypertensive conditions. For ACURATE neo2, these values were 3.97 MPa and 3.27 MPa. The results indicated that the unique characteristics of the Evolut FX may allow for better short-term functionality and long-term durability.","abstract_html":"Young, low-risk patients undergoing transcatheter heart valve replacement procedures have longer life expectancies that demand valves with superior durability, functionality, and long-term performance. Two transcatheter aortic valves, the Evolut FX and ACURATE neo2, were analyzed in finite element and digital image correlation experiments to determine their mechanical responses to normotensive and hypertensive conditions. Digital image correlation was used to evaluate the strain and displacement fields across the valve leaflets and as input data to conduct material parameter optimization. Finite element analyses were used to indicate the stress fields experienced by the valves. The maximum in-plane principal stress at the commissure level for Evolut FX was 0.53 MPa and 0.54 MPa for circular and elliptical configurations, respectively, under hypertensive conditions. For ACURATE neo2, these values were 3.97 MPa and 3.27 MPa. The results indicated that the unique characteristics of the Evolut FX may allow for better short-term functionality and long-term durability.","abstract_has_math":false,"creators":["Said, Steven"],"institution":null,"degree_name":"M.S. in Mechanical Engineering","degree_level":"Masters Thesis","degree_discipline":null,"degree_department":null,"school":null,"contributors":["Ali N. Azadani","Peter J. Laz","Rui Fan"],"advisors":[],"committee_chairs":[],"committee_members":[],"year":null,"date_issued":"","date_published":null,"updated_at":"2026-11-19T07:55:18Z","subjects":["Heart valve mechanics","digital image correlation","Trancatheter aortic valves","Finite element analysis","Material optimization","Tissue mechanics","Bioimaging and Biomedical Optics","Biomedical Devices and Instrumentation","Biomedical Engineering and Bioengineering"],"languages":["English (eng)"],"rights":["<p>Copyright is held by the author. Permanently suppressed.</p>","Steven Said"],"rights_urls":[],"identifier_entries":[{"key":"dc:identifier","label":"Identifier","values":["ETDCRP.2025.236"],"render_values":[{"text":"ETDCRP.2025.236","href":null,"code":true}]}],"person_identifier_entries":[]},"links":{"outbound_url":"https://digitalcommons.du.edu/etd/2681","outbound_label":"Repository record","outbound_source":"dc:identifier","record_url":"https://digitalcommons.du.edu/etd/2681","record_label":"Repository record","record_kind":"record","record_source":"dc:identifier","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://digitalcommons.du.edu/do/oai/?verb=GetRecord&metadataPrefix=oai_etdms&identifier=oai%3Adigitalcommons.du.edu%3Aetd-3911","prefix":"oai_etdms"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor","label":"Contributor","values":["Ali N. Azadani","Peter J. Laz","Rui Fan"]},{"key":"dc:creator","label":"Author","values":["Said, Steven"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.copyright","label":"Dc Date Copyright","values":["2025-11-01T07:00:00Z"]},{"key":"dc:date.created","label":"Dc Date Created","values":["2025-11-21T08:00:00Z"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Masters Thesis"]},{"key":"thesis:degree_name","label":"Degree Name","values":["M.S. in Mechanical Engineering"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Heart valve mechanics","digital image correlation","Trancatheter aortic valves","Finite element analysis","Material optimization","Tissue mechanics","Bioimaging and Biomedical Optics","Biomedical Devices and Instrumentation","Biomedical Engineering and Bioengineering"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language","label":"Dc Language","values":["English (eng)"]},{"key":"dc:rights","label":"Dc Rights","values":["<p>Copyright is held by the author. Permanently suppressed.</p>"]},{"key":"dc:rights.holder","label":"Dc Rights Holder","values":["Steven Said"]},{"key":"dc:rights.license","label":"Dc Rights License","values":["all_rights_reserved"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["ETDCRP.2025.236","https://digitalcommons.du.edu/etd/2681"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["Young, low-risk patients undergoing transcatheter heart valve replacement procedures have longer life expectancies that demand valves with superior durability, functionality, and long-term performance. Two transcatheter aortic valves, the Evolut FX and ACURATE neo2, were analyzed in finite element and digital image correlation experiments to determine their mechanical responses to normotensive and hypertensive conditions. Digital image correlation was used to evaluate the strain and displacement fields across the valve leaflets and as input data to conduct material parameter optimization. Finite element analyses were used to indicate the stress fields experienced by the valves. The maximum in-plane principal stress at the commissure level for Evolut FX was 0.53 MPa and 0.54 MPa for circular and elliptical configurations, respectively, under hypertensive conditions. For ACURATE neo2, these values were 3.97 MPa and 3.27 MPa. The results indicated that the unique characteristics of the Evolut FX may allow for better short-term functionality and long-term durability."]},{"key":"dc:description.provenance","label":"Dc Description Provenance","values":["Received from Author"]},{"key":"dc:format","label":"Dc Format","values":["application/pdf"]},{"key":"dc:format.extent","label":"Dc Format Extent","values":["132 pgs","9.3 MB"]},{"key":"dc:title","label":"Title","values":["Experimental and Computational Characterization of Transcatheter Aortic Valve Mechanics Using Digital Image Correlation and Finite Element Modeling"]}]}],"canonical_facts":{"dc:contributor":["Ali N. Azadani","Peter J. Laz","Rui Fan"],"dc:creator":["Said, Steven"],"dc:date.copyright":["2025-11-01T07:00:00Z"],"dc:date.created":["2025-11-21T08:00:00Z"],"dc:description.abstract":["Young, low-risk patients undergoing transcatheter heart valve replacement procedures have longer life expectancies that demand valves with superior durability, functionality, and long-term performance. Two transcatheter aortic valves, the Evolut FX and ACURATE neo2, were analyzed in finite element and digital image correlation experiments to determine their mechanical responses to normotensive and hypertensive conditions. Digital image correlation was used to evaluate the strain and displacement fields across the valve leaflets and as input data to conduct material parameter optimization. Finite element analyses were used to indicate the stress fields experienced by the valves. The maximum in-plane principal stress at the commissure level for Evolut FX was 0.53 MPa and 0.54 MPa for circular and elliptical configurations, respectively, under hypertensive conditions. For ACURATE neo2, these values were 3.97 MPa and 3.27 MPa. The results indicated that the unique characteristics of the Evolut FX may allow for better short-term functionality and long-term durability."],"dc:description.provenance":["Received from Author"],"dc:format":["application/pdf"],"dc:format.extent":["132 pgs","9.3 MB"],"dc:identifier":["ETDCRP.2025.236","https://digitalcommons.du.edu/etd/2681"],"dc:language":["English (eng)"],"dc:rights":["<p>Copyright is held by the author. Permanently suppressed.</p>"],"dc:rights.holder":["Steven Said"],"dc:rights.license":["all_rights_reserved"],"dc:subject":["Heart valve mechanics","digital image correlation","Trancatheter aortic valves","Finite element analysis","Material optimization","Tissue mechanics","Bioimaging and Biomedical Optics","Biomedical Devices and Instrumentation","Biomedical Engineering and Bioengineering"],"dc:title":["Experimental and Computational Characterization of Transcatheter Aortic Valve Mechanics Using Digital Image Correlation and Finite Element Modeling"],"thesis:degree_level":["Masters Thesis"],"thesis:degree_name":["M.S. in Mechanical Engineering"]},"updated_at":"2026-11-19T07:55:18Z"}