{"id":{"repo_id":"denver","oai_identifier":"oai:digitalcommons.du.edu:etd-3989"},"canonical_url":"https://search.ndltd.org/etd/denver/oai:digitalcommons.du.edu:etd-3989","repository":{"repo_id":"denver","name":"University of Denver","base_url":"https://digitalcommons.du.edu/do/oai/"},"display":{"title":"An Investigation of Pelvic Kinematics and Implications for Total Hip Arthroplasty","abstract":"Total hip arthroplasty (THA) is one of the most commonly performed orthopaedic procedures, with approximately 500,000 surgeries performed annually in the United States alone. Although THA is widely regarded as highly successful, postoperative complications persist, highlighting the multifactorial nature of THA outcomes. Previous studies have demonstrated the importance of implant positioning and soft tissue mechanics, yet challenges remain in optimizing surgical decisions on a patient-specific basis. Recent advances in surgical planning tools have shifted the focus of preoperative planning toward optimizing patient-specific outcomes, highlighting the need to better understand how patient anatomy, surgical technique, and joint mechanics interact to influence hip stability and postoperative function. The purpose of this dissertation was to investigate factors influencing THA outcomes through four primary studies, with a focus on hip stability and dislocation risk. The first study quantified pelvic tilt among THA patient cohorts during several functional static poses using in vivo high-speed stereo radiography (HSSR). Substantial variability in pelvic orientation was observed both within and between patient cohorts, suggesting that functional pose, and therefore optimal component placement, may be highly patient-specific and not reliably predicted solely by history of spinal fusion or prior arthroplasty. The second study characterized three-dimensional pelvic kinematics during key steps of the direct anterior approach THA, performed on an orthopaedic table in vitro. Motion capture data revealed procedure-dependent rotations toward the operative side during several surgical maneuvers, which may influence the accuracy of achieving intended component placement. The third study experimentally evaluated hip internal-external rotation and distraction behavior before and after THA, and developed computational models to assess corresponding changes in muscle mechanics. The results demonstrated significant alterations in hip stability following THA and identified strong correlations between changes in moment arms and global hip offset, suggesting the sensitivity of soft tissue structures to component positioning. The fourth study developed an automated workflow for patient-specific finite element modeling of the hip with three-dimensional muscle representations, presenting a computationally efficient framework to support future analyses of hip muscle mechanics. Together, these studies integrated clinical, experimental, and computational approaches to advance understanding of the biomechanical factors influencing THA outcomes and present a framework for improving surgical planning and patient-specific modeling.","abstract_html":"Total hip arthroplasty (THA) is one of the most commonly performed orthopaedic procedures, with approximately 500,000 surgeries performed annually in the United States alone. Although THA is widely regarded as highly successful, postoperative complications persist, highlighting the multifactorial nature of THA outcomes. Previous studies have demonstrated the importance of implant positioning and soft tissue mechanics, yet challenges remain in optimizing surgical decisions on a patient-specific basis. Recent advances in surgical planning tools have shifted the focus of preoperative planning toward optimizing patient-specific outcomes, highlighting the need to better understand how patient anatomy, surgical technique, and joint mechanics interact to influence hip stability and postoperative function. The purpose of this dissertation was to investigate factors influencing THA outcomes through four primary studies, with a focus on hip stability and dislocation risk. The first study quantified pelvic tilt among THA patient cohorts during several functional static poses using in vivo high-speed stereo radiography (HSSR). Substantial variability in pelvic orientation was observed both within and between patient cohorts, suggesting that functional pose, and therefore optimal component placement, may be highly patient-specific and not reliably predicted solely by history of spinal fusion or prior arthroplasty. The second study characterized three-dimensional pelvic kinematics during key steps of the direct anterior approach THA, performed on an orthopaedic table in vitro. Motion capture data revealed procedure-dependent rotations toward the operative side during several surgical maneuvers, which may influence the accuracy of achieving intended component placement. The third study experimentally evaluated hip internal-external rotation and distraction behavior before and after THA, and developed computational models to assess corresponding changes in muscle mechanics. The results demonstrated significant alterations in hip stability following THA and identified strong correlations between changes in moment arms and global hip offset, suggesting the sensitivity of soft tissue structures to component positioning. The fourth study developed an automated workflow for patient-specific finite element modeling of the hip with three-dimensional muscle representations, presenting a computationally efficient framework to support future analyses of hip muscle mechanics. Together, these studies integrated clinical, experimental, and computational approaches to advance understanding of the biomechanical factors influencing THA outcomes and present a framework for improving surgical planning and patient-specific modeling.","abstract_has_math":false,"creators":["Colone, Kathryn Holland"],"institution":null,"degree_name":"Ph.D. in Mechanical Engineering","degree_level":"Dissertation","degree_discipline":null,"degree_department":null,"school":null,"contributors":["Chadd W. Clary","Casey A. Myers","Paul J. Rullkoetter","Margareta Stefanovic"],"advisors":[],"committee_chairs":[],"committee_members":[],"year":null,"date_issued":"","date_published":null,"updated_at":"2026-11-19T07:55:22Z","subjects":["Biomechanics","Pelvic kinematics","Total hip arthroplasty (THA)","Biomechanical Engineering","Biomechanics and Biotransport","Biomedical Engineering and Bioengineering","Mechanical Engineering","Orthopedics","Surgery"],"languages":["English (eng)"],"rights":["<p>Copyright is held by the author. User is responsible for all copyright compliance.</p>","Kathryn Holland Colone"],"rights_urls":[],"identifier_entries":[{"key":"dc:identifier","label":"Identifier","values":["ETDCRP.2026.146","<a href=\"https://doi.org/10.56902/ETDCRP.2026.146\">https://doi.org/10.56902/ETDCRP.2026.146</a>","https://digitalcommons.du.edu/etd/2761"],"render_values":[{"text":"ETDCRP.2026.146","href":null,"code":true},{"text":"<a href=\"https://doi.org/10.56902/ETDCRP.2026.146\">https://doi.org/10.56902/ETDCRP.2026.146</a>","href":"https://doi.org/10.56902/ETDCRP.2026.146\">https://doi.org/10.56902/ETDCRP.2026.146</a>","code":true},{"text":"https://digitalcommons.du.edu/etd/2761","href":"https://digitalcommons.du.edu/etd/2761","code":true}]}],"person_identifier_entries":[]},"links":{"outbound_url":"https://doi.org/10.56902/ETDCRP.2026.146","outbound_label":"DOI","outbound_source":"dc:identifier","record_url":"https://doi.org/10.56902/ETDCRP.2026.146","record_label":"Repository record","record_kind":"doi","record_source":"dc:identifier","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://digitalcommons.du.edu/do/oai/?verb=GetRecord&metadataPrefix=oai_etdms&identifier=oai%3Adigitalcommons.du.edu%3Aetd-3989","prefix":"oai_etdms"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor","label":"Contributor","values":["Chadd W. Clary","Casey A. Myers","Paul J. Rullkoetter","Margareta Stefanovic"]},{"key":"dc:creator","label":"Author","values":["Colone, Kathryn Holland"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.copyright","label":"Dc Date Copyright","values":["2026-08-01T07:00:00Z"]},{"key":"dc:date.created","label":"Dc Date Created","values":["2026-08-22T07:00:00Z"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Dissertation"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Ph.D. in Mechanical Engineering"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Biomechanics","Pelvic kinematics","Total hip arthroplasty (THA)","Biomechanical Engineering","Biomechanics and Biotransport","Biomedical Engineering and Bioengineering","Mechanical Engineering","Orthopedics","Surgery"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language","label":"Dc Language","values":["English (eng)"]},{"key":"dc:rights","label":"Dc Rights","values":["<p>Copyright is held by the author. User is responsible for all copyright compliance.</p>"]},{"key":"dc:rights.holder","label":"Dc Rights Holder","values":["Kathryn Holland Colone"]},{"key":"dc:rights.license","label":"Dc Rights License","values":["all_rights_reserved"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["ETDCRP.2026.146","https://doi.org/10.56902/ETDCRP.2026.146","<a href=\"https://doi.org/10.56902/ETDCRP.2026.146\">https://doi.org/10.56902/ETDCRP.2026.146</a>","https://digitalcommons.du.edu/etd/2761"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["Total hip arthroplasty (THA) is one of the most commonly performed orthopaedic procedures, with approximately 500,000 surgeries performed annually in the United States alone. Although THA is widely regarded as highly successful, postoperative complications persist, highlighting the multifactorial nature of THA outcomes. Previous studies have demonstrated the importance of implant positioning and soft tissue mechanics, yet challenges remain in optimizing surgical decisions on a patient-specific basis. Recent advances in surgical planning tools have shifted the focus of preoperative planning toward optimizing patient-specific outcomes, highlighting the need to better understand how patient anatomy, surgical technique, and joint mechanics interact to influence hip stability and postoperative function. The purpose of this dissertation was to investigate factors influencing THA outcomes through four primary studies, with a focus on hip stability and dislocation risk. The first study quantified pelvic tilt among THA patient cohorts during several functional static poses using in vivo high-speed stereo radiography (HSSR). Substantial variability in pelvic orientation was observed both within and between patient cohorts, suggesting that functional pose, and therefore optimal component placement, may be highly patient-specific and not reliably predicted solely by history of spinal fusion or prior arthroplasty. The second study characterized three-dimensional pelvic kinematics during key steps of the direct anterior approach THA, performed on an orthopaedic table in vitro. Motion capture data revealed procedure-dependent rotations toward the operative side during several surgical maneuvers, which may influence the accuracy of achieving intended component placement. The third study experimentally evaluated hip internal-external rotation and distraction behavior before and after THA, and developed computational models to assess corresponding changes in muscle mechanics. The results demonstrated significant alterations in hip stability following THA and identified strong correlations between changes in moment arms and global hip offset, suggesting the sensitivity of soft tissue structures to component positioning. The fourth study developed an automated workflow for patient-specific finite element modeling of the hip with three-dimensional muscle representations, presenting a computationally efficient framework to support future analyses of hip muscle mechanics. Together, these studies integrated clinical, experimental, and computational approaches to advance understanding of the biomechanical factors influencing THA outcomes and present a framework for improving surgical planning and patient-specific modeling."]},{"key":"dc:description.provenance","label":"Dc Description Provenance","values":["Received from ProQuest"]},{"key":"dc:format","label":"Dc Format","values":["application/pdf"]},{"key":"dc:format.extent","label":"Dc Format Extent","values":["222 pgs","5.5 MB"]},{"key":"dc:title","label":"Title","values":["An Investigation of Pelvic Kinematics and Implications for Total Hip Arthroplasty"]}]}],"canonical_facts":{"dc:contributor":["Chadd W. Clary","Casey A. Myers","Paul J. Rullkoetter","Margareta Stefanovic"],"dc:creator":["Colone, Kathryn Holland"],"dc:date.copyright":["2026-08-01T07:00:00Z"],"dc:date.created":["2026-08-22T07:00:00Z"],"dc:description.abstract":["Total hip arthroplasty (THA) is one of the most commonly performed orthopaedic procedures, with approximately 500,000 surgeries performed annually in the United States alone. Although THA is widely regarded as highly successful, postoperative complications persist, highlighting the multifactorial nature of THA outcomes. Previous studies have demonstrated the importance of implant positioning and soft tissue mechanics, yet challenges remain in optimizing surgical decisions on a patient-specific basis. Recent advances in surgical planning tools have shifted the focus of preoperative planning toward optimizing patient-specific outcomes, highlighting the need to better understand how patient anatomy, surgical technique, and joint mechanics interact to influence hip stability and postoperative function. The purpose of this dissertation was to investigate factors influencing THA outcomes through four primary studies, with a focus on hip stability and dislocation risk. The first study quantified pelvic tilt among THA patient cohorts during several functional static poses using in vivo high-speed stereo radiography (HSSR). Substantial variability in pelvic orientation was observed both within and between patient cohorts, suggesting that functional pose, and therefore optimal component placement, may be highly patient-specific and not reliably predicted solely by history of spinal fusion or prior arthroplasty. The second study characterized three-dimensional pelvic kinematics during key steps of the direct anterior approach THA, performed on an orthopaedic table in vitro. Motion capture data revealed procedure-dependent rotations toward the operative side during several surgical maneuvers, which may influence the accuracy of achieving intended component placement. The third study experimentally evaluated hip internal-external rotation and distraction behavior before and after THA, and developed computational models to assess corresponding changes in muscle mechanics. The results demonstrated significant alterations in hip stability following THA and identified strong correlations between changes in moment arms and global hip offset, suggesting the sensitivity of soft tissue structures to component positioning. The fourth study developed an automated workflow for patient-specific finite element modeling of the hip with three-dimensional muscle representations, presenting a computationally efficient framework to support future analyses of hip muscle mechanics. Together, these studies integrated clinical, experimental, and computational approaches to advance understanding of the biomechanical factors influencing THA outcomes and present a framework for improving surgical planning and patient-specific modeling."],"dc:description.provenance":["Received from ProQuest"],"dc:format":["application/pdf"],"dc:format.extent":["222 pgs","5.5 MB"],"dc:identifier":["ETDCRP.2026.146","https://doi.org/10.56902/ETDCRP.2026.146","<a href=\"https://doi.org/10.56902/ETDCRP.2026.146\">https://doi.org/10.56902/ETDCRP.2026.146</a>","https://digitalcommons.du.edu/etd/2761"],"dc:language":["English (eng)"],"dc:rights":["<p>Copyright is held by the author. User is responsible for all copyright compliance.</p>"],"dc:rights.holder":["Kathryn Holland Colone"],"dc:rights.license":["all_rights_reserved"],"dc:subject":["Biomechanics","Pelvic kinematics","Total hip arthroplasty (THA)","Biomechanical Engineering","Biomechanics and Biotransport","Biomedical Engineering and Bioengineering","Mechanical Engineering","Orthopedics","Surgery"],"dc:title":["An Investigation of Pelvic Kinematics and Implications for Total Hip Arthroplasty"],"thesis:degree_level":["Dissertation"],"thesis:degree_name":["Ph.D. in Mechanical Engineering"]},"updated_at":"2026-11-19T07:55:22Z"}