{"id":{"repo_id":"duke","oai_identifier":"oai:dukespace.lib.duke.edu:10161/1654"},"canonical_url":"https://search.ndltd.org/etd/duke/oai:dukespace.lib.duke.edu:10161/1654","repository":{"repo_id":"duke","name":"Duke University","base_url":"https://dukespace.lib.duke.edu/server/oai/request"},"display":{"title":"Modeling, Fabrication, and Test of a CMOS Integrated Circuit Platform for Electrophoretic Control of On-Chip Heterogeneous Fluids: toward Particle Separation on a Custom CMOS Chip","abstract":"<p>Electrophoresis is the migration of charged particles in a heterogeneous fluid under the influence of an electric field. This project is work toward an electrophoretic separation system on a custom CMOS chip. Modeling, fabrication, and testing of an AMI ABN 1.5 um CMOS chip for this application is discussed. The unique approach is to build the entire system using conventional CMOS integrated circuit technology, such that the separation area is fabricated on the chip with integrated control and detection circuitry. To achieve the desired functionality, a novel configuration of an electrophoresis system is implemented. In this system, instead of using only one electrode at each end of the separation area, a multitude of electrodes beneath the entire separation area are utilized, enabling better control of high electric fields using very small voltages over small areas. Electronic circuits control the position and strength of the electric field to drive the separations and to simultaneously detect the location and concentration of samples within the separation area. Ultimately, the project was successful at showing that implementing an electrophoresis system on standard CMOS is possible.</p>","abstract_html":"&lt;p&gt;Electrophoresis is the migration of charged particles in a heterogeneous fluid under the influence of an electric field. This project is work toward an electrophoretic separation system on a custom CMOS chip. Modeling, fabrication, and testing of an AMI ABN 1.5 um CMOS chip for this application is discussed. The unique approach is to build the entire system using conventional CMOS integrated circuit technology, such that the separation area is fabricated on the chip with integrated control and detection circuitry. To achieve the desired functionality, a novel configuration of an electrophoresis system is implemented. In this system, instead of using only one electrode at each end of the separation area, a multitude of electrodes beneath the entire separation area are utilized, enabling better control of high electric fields using very small voltages over small areas. Electronic circuits control the position and strength of the electric field to drive the separations and to simultaneously detect the location and concentration of samples within the separation area. Ultimately, the project was successful at showing that implementing an electrophoresis system on standard CMOS is possible.&lt;/p&gt;","abstract_has_math":false,"creators":["Wake, Heather Anne"],"institution":null,"degree_name":null,"degree_level":null,"degree_discipline":null,"degree_department":"Electrical and Computer Engineering","school":null,"contributors":[],"advisors":["Brooke, Martin A"],"committee_chairs":[],"committee_members":[],"year":2009,"date_issued":"2009","date_published":"2009","updated_at":"2026-11-19T08:24:52Z","subjects":["Engineering, Electronics and Electrical","CMOS","electrophoresis","Integrated circuits","lab on a chip","Microfluidics","Separation"],"languages":["en_US"],"rights":[],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"https://hdl.handle.net/10161/1654","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"https://hdl.handle.net/10161/1654","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Aduke%3Aoai%3Adukespace.lib.duke.edu%3A10161%2F1654","prefix":"oai_dc"},"source_record":{"url":"https://dukespace.lib.duke.edu/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Adukespace.lib.duke.edu%3A10161%2F1654","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Brooke, Martin A"]},{"key":"dc:contributor.department","label":"Department","values":["Electrical and Computer Engineering"]},{"key":"dc:creator","label":"Author","values":["Wake, Heather Anne"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2009-12-18T16:34:37Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2011-12-31T05:30:07Z"]},{"key":"dc:date.issued","label":"Date","values":["2009"]},{"key":"dc:type","label":"Dc Type","values":["Dissertation"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Engineering, Electronics and Electrical","CMOS","electrophoresis","Integrated circuits","lab on a chip","Microfluidics","Separation"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["en_US"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://hdl.handle.net/10161/1654"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["<p>Electrophoresis is the migration of charged particles in a heterogeneous fluid under the influence of an electric field. This project is work toward an electrophoretic separation system on a custom CMOS chip. Modeling, fabrication, and testing of an AMI ABN 1.5 um CMOS chip for this application is discussed. The unique approach is to build the entire system using conventional CMOS integrated circuit technology, such that the separation area is fabricated on the chip with integrated control and detection circuitry. To achieve the desired functionality, a novel configuration of an electrophoresis system is implemented. In this system, instead of using only one electrode at each end of the separation area, a multitude of electrodes beneath the entire separation area are utilized, enabling better control of high electric fields using very small voltages over small areas. Electronic circuits control the position and strength of the electric field to drive the separations and to simultaneously detect the location and concentration of samples within the separation area. Ultimately, the project was successful at showing that implementing an electrophoresis system on standard CMOS is possible.</p>"]},{"key":"dc:embargo.terms","label":"Dc Embargo Terms","values":["24"]},{"key":"dc:title","label":"Title","values":["Modeling, Fabrication, and Test of a CMOS Integrated Circuit Platform for Electrophoretic Control of On-Chip Heterogeneous Fluids: toward Particle Separation on a Custom CMOS Chip"]},{"key":"others:access_status","label":"Others Access Status","values":["open.access"]}]}],"canonical_facts":{"dc:contributor.advisor":["Brooke, Martin A"],"dc:contributor.department":["Electrical and Computer Engineering"],"dc:creator":["Wake, Heather Anne"],"dc:date.accessioned":["2009-12-18T16:34:37Z"],"dc:date.available":["2011-12-31T05:30:07Z"],"dc:date.issued":["2009"],"dc:description.abstract":["<p>Electrophoresis is the migration of charged particles in a heterogeneous fluid under the influence of an electric field. This project is work toward an electrophoretic separation system on a custom CMOS chip. Modeling, fabrication, and testing of an AMI ABN 1.5 um CMOS chip for this application is discussed. The unique approach is to build the entire system using conventional CMOS integrated circuit technology, such that the separation area is fabricated on the chip with integrated control and detection circuitry. To achieve the desired functionality, a novel configuration of an electrophoresis system is implemented. In this system, instead of using only one electrode at each end of the separation area, a multitude of electrodes beneath the entire separation area are utilized, enabling better control of high electric fields using very small voltages over small areas. Electronic circuits control the position and strength of the electric field to drive the separations and to simultaneously detect the location and concentration of samples within the separation area. Ultimately, the project was successful at showing that implementing an electrophoresis system on standard CMOS is possible.</p>"],"dc:embargo.terms":["24"],"dc:identifier.uri":["https://hdl.handle.net/10161/1654"],"dc:language.iso":["en_US"],"dc:subject":["Engineering, Electronics and Electrical","CMOS","electrophoresis","Integrated circuits","lab on a chip","Microfluidics","Separation"],"dc:title":["Modeling, Fabrication, and Test of a CMOS Integrated Circuit Platform for Electrophoretic Control of On-Chip Heterogeneous Fluids: toward Particle Separation on a Custom CMOS Chip"],"dc:type":["Dissertation"],"others:access_status":["open.access"]},"updated_at":"2026-11-19T08:24:52Z"}