{"id":{"repo_id":"duke","oai_identifier":"oai:dukespace.lib.duke.edu:10161/35170"},"canonical_url":"https://search.ndltd.org/etd/duke/oai:dukespace.lib.duke.edu:10161/35170","repository":{"repo_id":"duke","name":"Duke University","base_url":"https://dukespace.lib.duke.edu/server/oai/request"},"display":{"title":"Advancing Multi-Center 129Xe Gas Exchange MRI Through Advanced Segmentation, Artifact Mitigation, and Establishing Reference Distributions","abstract":"<p>Pulmonary diseases impose a major clinical burden, yet many standard clinical assess-ments remain limited in their ability to capture regional dysfunction and to support robust comparison across subjects, sites, and scanner platforms. Hyperpolarized 129Xe MRI/MRS offers a powerful way to probe lung function by providing spatially resolved ventilation imaging as well as compartment-resolved gas-exchange measurements that reflect transfer from alveolar airspaces to the interstitial membrane and to red blood cells. However, translating these capabil-ities into quantitative, multi-site–ready biomarkers requires analysis workflows that are auto-mated, standardized, and resilient to dominant technical confounders.</p><p>The central hypothesis of this dissertation is that robust multi-site quantification can be achieved by (i) reducing reliance on auxiliary acquisitions and manual processing steps that in-troduce variability, (ii) establishing harmonized healthy reference distributions that enable con-sistent interpretation across vendors, and (iii) identifying and controlling confounders—particularly intensity inhomogeneity, incidental gas-phase excitation, and decay-correction as-sumptions—that can systematically bias derived metrics.</p><p>Chapter 2 reviews pulmonary physiology and the core principles of 129Xe MRI/MRS that motivate ventilation and dissolved-phase biomarkers, including how compartment-resolved imaging supports interpretation of gas-exchange impairments. </p><p>Chapter 3 addresses a key scalability bottleneck—thoracic cavity segmentation—by de-veloping a xenon-only deep learning framework that eliminates dependence on registered pro-ton scans. Because annotated training volumes are scarce in 129Xe MRI, the framework com-bines template-based augmentation with Pix2Pix GAN-based synthesis to expand anatomical and defect-pattern diversity, and demonstrates strong agreement between model-derived and expert-derived thoracic cavity volume and ventilation defect percentage.</p><p>Chapter 4 establishes standardized healthy reference distributions and normative values for multi-site 129Xe gas-exchange MRI/MRS in a young healthy cohort spanning Siemens, Philips, and GE platforms, providing a foundation for consistent quantitative interpretation across centers. </p><p>Chapter 5 addresses incidental gas-phase excitation during dissolved-phase imaging by implementing and directly comparing two leading correction strategies (dual-echo and spectros-copy-informed frameworks) under matched acquisition conditions on Siemens, and by deriving quantitative thresholds for tolerable contamination to support reliable gas-exchange metrics.</p><p>Chapter 6 extends robustness and physiologic interpretability in three ways. First, it evaluates multi-step versus standard N4ITK bias-field correction for 129Xe ventilation MRI us-ing blinded expert reader analysis, supporting multi-step correction as a preferred approach for improving uniformity and defect depiction in multi-center workflows. Second, it outlines a conceptual framework for imaging collateral ventilation beyond a single breath-hold by inte-grating a spiral-based acquisition strategy and optimized breathing maneuvers, with planned comparisons to sampling-efficient trajectories. Third, it motivates spatially resolved estimation of membrane and RBC T2* using 129Xe chemical shift imaging to improve decay correction beyond whole-lung spectroscopy assumptions.</p><p>Chapter 7 concludes by outlining future directions to improve robustness and clinical utility, emphasizing trachea-aware/user-guided segmentation, expanded normative reference cohorts, and more physiology-informed correction strategies for multi-site deployment.</p><p>Together, these contributions advance 129Xe MRI/MRS from a powerful functional im-aging capability toward a standardized and scalable quantitative biomarker platform suitable for multi-site studies and broader clinical translation.</p>","abstract_html":"&lt;p&gt;Pulmonary diseases impose a major clinical burden, yet many standard clinical assess-ments remain limited in their ability to capture regional dysfunction and to support robust comparison across subjects, sites, and scanner platforms. Hyperpolarized 129Xe MRI/MRS offers a powerful way to probe lung function by providing spatially resolved ventilation imaging as well as compartment-resolved gas-exchange measurements that reflect transfer from alveolar airspaces to the interstitial membrane and to red blood cells. However, translating these capabil-ities into quantitative, multi-site–ready biomarkers requires analysis workflows that are auto-mated, standardized, and resilient to dominant technical confounders.&lt;/p&gt;&lt;p&gt;The central hypothesis of this dissertation is that robust multi-site quantification can be achieved by (i) reducing reliance on auxiliary acquisitions and manual processing steps that in-troduce variability, (ii) establishing harmonized healthy reference distributions that enable con-sistent interpretation across vendors, and (iii) identifying and controlling confounders—particularly intensity inhomogeneity, incidental gas-phase excitation, and decay-correction as-sumptions—that can systematically bias derived metrics.&lt;/p&gt;&lt;p&gt;Chapter 2 reviews pulmonary physiology and the core principles of 129Xe MRI/MRS that motivate ventilation and dissolved-phase biomarkers, including how compartment-resolved imaging supports interpretation of gas-exchange impairments. &lt;/p&gt;&lt;p&gt;Chapter 3 addresses a key scalability bottleneck—thoracic cavity segmentation—by de-veloping a xenon-only deep learning framework that eliminates dependence on registered pro-ton scans. Because annotated training volumes are scarce in 129Xe MRI, the framework com-bines template-based augmentation with Pix2Pix GAN-based synthesis to expand anatomical and defect-pattern diversity, and demonstrates strong agreement between model-derived and expert-derived thoracic cavity volume and ventilation defect percentage.&lt;/p&gt;&lt;p&gt;Chapter 4 establishes standardized healthy reference distributions and normative values for multi-site 129Xe gas-exchange MRI/MRS in a young healthy cohort spanning Siemens, Philips, and GE platforms, providing a foundation for consistent quantitative interpretation across centers. &lt;/p&gt;&lt;p&gt;Chapter 5 addresses incidental gas-phase excitation during dissolved-phase imaging by implementing and directly comparing two leading correction strategies (dual-echo and spectros-copy-informed frameworks) under matched acquisition conditions on Siemens, and by deriving quantitative thresholds for tolerable contamination to support reliable gas-exchange metrics.&lt;/p&gt;&lt;p&gt;Chapter 6 extends robustness and physiologic interpretability in three ways. First, it evaluates multi-step versus standard N4ITK bias-field correction for 129Xe ventilation MRI us-ing blinded expert reader analysis, supporting multi-step correction as a preferred approach for improving uniformity and defect depiction in multi-center workflows. Second, it outlines a conceptual framework for imaging collateral ventilation beyond a single breath-hold by inte-grating a spiral-based acquisition strategy and optimized breathing maneuvers, with planned comparisons to sampling-efficient trajectories. Third, it motivates spatially resolved estimation of membrane and RBC T2* using 129Xe chemical shift imaging to improve decay correction beyond whole-lung spectroscopy assumptions.&lt;/p&gt;&lt;p&gt;Chapter 7 concludes by outlining future directions to improve robustness and clinical utility, emphasizing trachea-aware/user-guided segmentation, expanded normative reference cohorts, and more physiology-informed correction strategies for multi-site deployment.&lt;/p&gt;&lt;p&gt;Together, these contributions advance 129Xe MRI/MRS from a powerful functional im-aging capability toward a standardized and scalable quantitative biomarker platform suitable for multi-site studies and broader clinical translation.&lt;/p&gt;","abstract_has_math":false,"creators":["Leewiwatwong, Suphachart"],"institution":null,"degree_name":null,"degree_level":null,"degree_discipline":null,"degree_department":"Biomedical Engineering","school":null,"contributors":[],"advisors":["Driehuys, Bastiaan"],"committee_chairs":[],"committee_members":[],"year":2026,"date_issued":"2026","date_published":"2026","updated_at":"2026-11-19T08:26:56Z","subjects":["Biomedical engineering","Medical imaging","129Xe gas exchange MRI/MRS","Deep learning Segmentation","Gas-phase contamination correction","Healthy reference distributions","Multisite standardization","Spatially resolved T2* mapping"],"languages":[],"rights":[],"rights_urls":["https://creativecommons.org/licenses/by-nc-nd/4.0/"],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"https://hdl.handle.net/10161/35170","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"https://hdl.handle.net/10161/35170","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Aduke%3Aoai%3Adukespace.lib.duke.edu%3A10161%2F35170","prefix":"oai_dc"},"source_record":{"url":"https://dukespace.lib.duke.edu/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Adukespace.lib.duke.edu%3A10161%2F35170","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Driehuys, Bastiaan"]},{"key":"dc:contributor.department","label":"Department","values":["Biomedical Engineering"]},{"key":"dc:creator","label":"Author","values":["Leewiwatwong, Suphachart"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2026-07-06T20:15:29Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2026-07-06T20:15:29Z"]},{"key":"dc:date.issued","label":"Date","values":["2026"]},{"key":"dc:type","label":"Dc Type","values":["Dissertation"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Biomedical engineering","Medical imaging","129Xe gas exchange MRI/MRS","Deep learning Segmentation","Gas-phase contamination correction","Healthy reference distributions","Multisite standardization","Spatially resolved T2* mapping"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:rights.uri","label":"Rights URI","values":["https://creativecommons.org/licenses/by-nc-nd/4.0/"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://hdl.handle.net/10161/35170"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["<p>Pulmonary diseases impose a major clinical burden, yet many standard clinical assess-ments remain limited in their ability to capture regional dysfunction and to support robust comparison across subjects, sites, and scanner platforms. Hyperpolarized 129Xe MRI/MRS offers a powerful way to probe lung function by providing spatially resolved ventilation imaging as well as compartment-resolved gas-exchange measurements that reflect transfer from alveolar airspaces to the interstitial membrane and to red blood cells. However, translating these capabil-ities into quantitative, multi-site–ready biomarkers requires analysis workflows that are auto-mated, standardized, and resilient to dominant technical confounders.</p><p>The central hypothesis of this dissertation is that robust multi-site quantification can be achieved by (i) reducing reliance on auxiliary acquisitions and manual processing steps that in-troduce variability, (ii) establishing harmonized healthy reference distributions that enable con-sistent interpretation across vendors, and (iii) identifying and controlling confounders—particularly intensity inhomogeneity, incidental gas-phase excitation, and decay-correction as-sumptions—that can systematically bias derived metrics.</p><p>Chapter 2 reviews pulmonary physiology and the core principles of 129Xe MRI/MRS that motivate ventilation and dissolved-phase biomarkers, including how compartment-resolved imaging supports interpretation of gas-exchange impairments. </p><p>Chapter 3 addresses a key scalability bottleneck—thoracic cavity segmentation—by de-veloping a xenon-only deep learning framework that eliminates dependence on registered pro-ton scans. Because annotated training volumes are scarce in 129Xe MRI, the framework com-bines template-based augmentation with Pix2Pix GAN-based synthesis to expand anatomical and defect-pattern diversity, and demonstrates strong agreement between model-derived and expert-derived thoracic cavity volume and ventilation defect percentage.</p><p>Chapter 4 establishes standardized healthy reference distributions and normative values for multi-site 129Xe gas-exchange MRI/MRS in a young healthy cohort spanning Siemens, Philips, and GE platforms, providing a foundation for consistent quantitative interpretation across centers. </p><p>Chapter 5 addresses incidental gas-phase excitation during dissolved-phase imaging by implementing and directly comparing two leading correction strategies (dual-echo and spectros-copy-informed frameworks) under matched acquisition conditions on Siemens, and by deriving quantitative thresholds for tolerable contamination to support reliable gas-exchange metrics.</p><p>Chapter 6 extends robustness and physiologic interpretability in three ways. First, it evaluates multi-step versus standard N4ITK bias-field correction for 129Xe ventilation MRI us-ing blinded expert reader analysis, supporting multi-step correction as a preferred approach for improving uniformity and defect depiction in multi-center workflows. Second, it outlines a conceptual framework for imaging collateral ventilation beyond a single breath-hold by inte-grating a spiral-based acquisition strategy and optimized breathing maneuvers, with planned comparisons to sampling-efficient trajectories. Third, it motivates spatially resolved estimation of membrane and RBC T2* using 129Xe chemical shift imaging to improve decay correction beyond whole-lung spectroscopy assumptions.</p><p>Chapter 7 concludes by outlining future directions to improve robustness and clinical utility, emphasizing trachea-aware/user-guided segmentation, expanded normative reference cohorts, and more physiology-informed correction strategies for multi-site deployment.</p><p>Together, these contributions advance 129Xe MRI/MRS from a powerful functional im-aging capability toward a standardized and scalable quantitative biomarker platform suitable for multi-site studies and broader clinical translation.</p>"]},{"key":"dc:title","label":"Title","values":["Advancing Multi-Center 129Xe Gas Exchange MRI Through Advanced Segmentation, Artifact Mitigation, and Establishing Reference Distributions"]},{"key":"others:access_status","label":"Others Access Status","values":["open.access"]}]}],"canonical_facts":{"dc:contributor.advisor":["Driehuys, Bastiaan"],"dc:contributor.department":["Biomedical Engineering"],"dc:creator":["Leewiwatwong, Suphachart"],"dc:date.accessioned":["2026-07-06T20:15:29Z"],"dc:date.available":["2026-07-06T20:15:29Z"],"dc:date.issued":["2026"],"dc:description.abstract":["<p>Pulmonary diseases impose a major clinical burden, yet many standard clinical assess-ments remain limited in their ability to capture regional dysfunction and to support robust comparison across subjects, sites, and scanner platforms. Hyperpolarized 129Xe MRI/MRS offers a powerful way to probe lung function by providing spatially resolved ventilation imaging as well as compartment-resolved gas-exchange measurements that reflect transfer from alveolar airspaces to the interstitial membrane and to red blood cells. However, translating these capabil-ities into quantitative, multi-site–ready biomarkers requires analysis workflows that are auto-mated, standardized, and resilient to dominant technical confounders.</p><p>The central hypothesis of this dissertation is that robust multi-site quantification can be achieved by (i) reducing reliance on auxiliary acquisitions and manual processing steps that in-troduce variability, (ii) establishing harmonized healthy reference distributions that enable con-sistent interpretation across vendors, and (iii) identifying and controlling confounders—particularly intensity inhomogeneity, incidental gas-phase excitation, and decay-correction as-sumptions—that can systematically bias derived metrics.</p><p>Chapter 2 reviews pulmonary physiology and the core principles of 129Xe MRI/MRS that motivate ventilation and dissolved-phase biomarkers, including how compartment-resolved imaging supports interpretation of gas-exchange impairments. </p><p>Chapter 3 addresses a key scalability bottleneck—thoracic cavity segmentation—by de-veloping a xenon-only deep learning framework that eliminates dependence on registered pro-ton scans. Because annotated training volumes are scarce in 129Xe MRI, the framework com-bines template-based augmentation with Pix2Pix GAN-based synthesis to expand anatomical and defect-pattern diversity, and demonstrates strong agreement between model-derived and expert-derived thoracic cavity volume and ventilation defect percentage.</p><p>Chapter 4 establishes standardized healthy reference distributions and normative values for multi-site 129Xe gas-exchange MRI/MRS in a young healthy cohort spanning Siemens, Philips, and GE platforms, providing a foundation for consistent quantitative interpretation across centers. </p><p>Chapter 5 addresses incidental gas-phase excitation during dissolved-phase imaging by implementing and directly comparing two leading correction strategies (dual-echo and spectros-copy-informed frameworks) under matched acquisition conditions on Siemens, and by deriving quantitative thresholds for tolerable contamination to support reliable gas-exchange metrics.</p><p>Chapter 6 extends robustness and physiologic interpretability in three ways. First, it evaluates multi-step versus standard N4ITK bias-field correction for 129Xe ventilation MRI us-ing blinded expert reader analysis, supporting multi-step correction as a preferred approach for improving uniformity and defect depiction in multi-center workflows. Second, it outlines a conceptual framework for imaging collateral ventilation beyond a single breath-hold by inte-grating a spiral-based acquisition strategy and optimized breathing maneuvers, with planned comparisons to sampling-efficient trajectories. Third, it motivates spatially resolved estimation of membrane and RBC T2* using 129Xe chemical shift imaging to improve decay correction beyond whole-lung spectroscopy assumptions.</p><p>Chapter 7 concludes by outlining future directions to improve robustness and clinical utility, emphasizing trachea-aware/user-guided segmentation, expanded normative reference cohorts, and more physiology-informed correction strategies for multi-site deployment.</p><p>Together, these contributions advance 129Xe MRI/MRS from a powerful functional im-aging capability toward a standardized and scalable quantitative biomarker platform suitable for multi-site studies and broader clinical translation.</p>"],"dc:identifier.uri":["https://hdl.handle.net/10161/35170"],"dc:rights.uri":["https://creativecommons.org/licenses/by-nc-nd/4.0/"],"dc:subject":["Biomedical engineering","Medical imaging","129Xe gas exchange MRI/MRS","Deep learning Segmentation","Gas-phase contamination correction","Healthy reference distributions","Multisite standardization","Spatially resolved T2* mapping"],"dc:title":["Advancing Multi-Center 129Xe Gas Exchange MRI Through Advanced Segmentation, Artifact Mitigation, and Establishing Reference Distributions"],"dc:type":["Dissertation"],"others:access_status":["open.access"]},"updated_at":"2026-11-19T08:26:56Z"}