{"id":{"repo_id":"duke","oai_identifier":"oai:dukespace.lib.duke.edu:10161/35711"},"canonical_url":"https://search.ndltd.org/etd/duke/oai:dukespace.lib.duke.edu:10161/35711","repository":{"repo_id":"duke","name":"Duke University","base_url":"https://dukespace.lib.duke.edu/server/oai/request"},"display":{"title":"Three-dimensional Passive Cavitation Mapping during Laser Lithotripsy","abstract":"<p>Laser lithotripsy (LL) is the gold-standard treatment for kidney stones; however, its clinical efficacy remains limited by the lack of real-time, quantitative feedback regarding the mechanical energy delivered to the stone. Currently, urologists rely primarily on subjective visual estimation through endoscopy, which is often obscured by debris and offers no depth-resolved information. This dissertation presents the development of an integrated three-dimensional passive cavitation mapping (3D-PCM) platform designed to provide non-invasive, real-time, and super-resolved monitoring of laser-induced cavitation activities.The research progresses through three major stages of innovation. First, a first-generation 3D Super-Resolution PCM (3D-SRPCM) framework was established. By implementing a radial symmetry localization algorithm, the system surpassed the acoustic diffraction limit, achieving sub-millimeter spatial precision. Through multimodal validation with high-speed imaging and optical coherence tomography (OCT), \"Accumulated Impact Pressure\" (Acc IP) was identified and validated as a robust quantitative biomarker ( γ =0.93) for predicting volumetric stone damage. Second, to address the computational demands of intraoperative monitoring, a GPU-accelerated beamforming architecture was developed. By optimizing sparse-matrix multiplication, the reconstruction latency was reduced to under 1 ms, enabling the spatiotemporal decoupling of complex cascading cavitation events. To further bridge the gap to clinical application, a custom 5 MHz, 256-element planar 2D matrix array was engineered. This second-generation hardware provides a deep field-of-view (FOV) exceeding 100 mm, ensuring consistent functional localization in deep-seated human tissues. Finally, the platform was translated into a pre-clinical swine model. To combat physiological motion, the transducer was integrated with a multi-axis robotic arm governed by a closed-loop automatic repositioning algorithm. This system dynamically tracks the target stone using real-time 3D-PCM feedback, ensuring optimal acoustic coupling throughout the surgery. The results demonstrate that the integrated platform can accurately reconstruct surgical trajectories and provide intuitive, color-coded feedback on therapeutic efficacy. Collectively, this work provides a foundational engineering framework for the next generation of \"navigation-guided\" intelligent lithotripsy systems, promising to enhance surgical precision and patient safety in urology. </p>","abstract_html":"&lt;p&gt;Laser lithotripsy (LL) is the gold-standard treatment for kidney stones; however, its clinical efficacy remains limited by the lack of real-time, quantitative feedback regarding the mechanical energy delivered to the stone. Currently, urologists rely primarily on subjective visual estimation through endoscopy, which is often obscured by debris and offers no depth-resolved information. This dissertation presents the development of an integrated three-dimensional passive cavitation mapping (3D-PCM) platform designed to provide non-invasive, real-time, and super-resolved monitoring of laser-induced cavitation activities.The research progresses through three major stages of innovation. First, a first-generation 3D Super-Resolution PCM (3D-SRPCM) framework was established. By implementing a radial symmetry localization algorithm, the system surpassed the acoustic diffraction limit, achieving sub-millimeter spatial precision. Through multimodal validation with high-speed imaging and optical coherence tomography (OCT), &quot;Accumulated Impact Pressure&quot; (Acc IP) was identified and validated as a robust quantitative biomarker ( γ =0.93) for predicting volumetric stone damage. Second, to address the computational demands of intraoperative monitoring, a GPU-accelerated beamforming architecture was developed. By optimizing sparse-matrix multiplication, the reconstruction latency was reduced to under 1 ms, enabling the spatiotemporal decoupling of complex cascading cavitation events. To further bridge the gap to clinical application, a custom 5 MHz, 256-element planar 2D matrix array was engineered. This second-generation hardware provides a deep field-of-view (FOV) exceeding 100 mm, ensuring consistent functional localization in deep-seated human tissues. Finally, the platform was translated into a pre-clinical swine model. To combat physiological motion, the transducer was integrated with a multi-axis robotic arm governed by a closed-loop automatic repositioning algorithm. This system dynamically tracks the target stone using real-time 3D-PCM feedback, ensuring optimal acoustic coupling throughout the surgery. The results demonstrate that the integrated platform can accurately reconstruct surgical trajectories and provide intuitive, color-coded feedback on therapeutic efficacy. Collectively, this work provides a foundational engineering framework for the next generation of &quot;navigation-guided&quot; intelligent lithotripsy systems, promising to enhance surgical precision and patient safety in urology. &lt;/p&gt;","abstract_has_math":false,"creators":["Li, Daiwei"],"institution":null,"degree_name":null,"degree_level":null,"degree_discipline":null,"degree_department":"Biomedical Engineering","school":null,"contributors":[],"advisors":["Yao, Junjie"],"committee_chairs":[],"committee_members":[],"year":2026,"date_issued":"2026","date_published":"2026","updated_at":"2026-11-19T08:26:43Z","subjects":["Biomedical engineering"],"languages":[],"rights":[],"rights_urls":["https://creativecommons.org/licenses/by-nc-nd/4.0/"],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"https://hdl.handle.net/10161/35711","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"https://hdl.handle.net/10161/35711","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Aduke%3Aoai%3Adukespace.lib.duke.edu%3A10161%2F35711","prefix":"oai_dc"},"source_record":{"url":"https://dukespace.lib.duke.edu/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Adukespace.lib.duke.edu%3A10161%2F35711","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Yao, Junjie"]},{"key":"dc:contributor.department","label":"Department","values":["Biomedical Engineering"]},{"key":"dc:creator","label":"Author","values":["Li, Daiwei"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2026-09-22T18:42:09Z"]},{"key":"dc:date.issued","label":"Date","values":["2026"]},{"key":"dc:date.liftdate","label":"Dc Date Liftdate","values":["2028-09-22T18:42:09Z"]},{"key":"dc:type","label":"Dc Type","values":["Dissertation"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Biomedical engineering"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:rights.uri","label":"Rights URI","values":["https://creativecommons.org/licenses/by-nc-nd/4.0/"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://hdl.handle.net/10161/35711"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["<p>Laser lithotripsy (LL) is the gold-standard treatment for kidney stones; however, its clinical efficacy remains limited by the lack of real-time, quantitative feedback regarding the mechanical energy delivered to the stone. Currently, urologists rely primarily on subjective visual estimation through endoscopy, which is often obscured by debris and offers no depth-resolved information. This dissertation presents the development of an integrated three-dimensional passive cavitation mapping (3D-PCM) platform designed to provide non-invasive, real-time, and super-resolved monitoring of laser-induced cavitation activities.The research progresses through three major stages of innovation. First, a first-generation 3D Super-Resolution PCM (3D-SRPCM) framework was established. By implementing a radial symmetry localization algorithm, the system surpassed the acoustic diffraction limit, achieving sub-millimeter spatial precision. Through multimodal validation with high-speed imaging and optical coherence tomography (OCT), \"Accumulated Impact Pressure\" (Acc IP) was identified and validated as a robust quantitative biomarker ( γ =0.93) for predicting volumetric stone damage. Second, to address the computational demands of intraoperative monitoring, a GPU-accelerated beamforming architecture was developed. By optimizing sparse-matrix multiplication, the reconstruction latency was reduced to under 1 ms, enabling the spatiotemporal decoupling of complex cascading cavitation events. To further bridge the gap to clinical application, a custom 5 MHz, 256-element planar 2D matrix array was engineered. This second-generation hardware provides a deep field-of-view (FOV) exceeding 100 mm, ensuring consistent functional localization in deep-seated human tissues. Finally, the platform was translated into a pre-clinical swine model. To combat physiological motion, the transducer was integrated with a multi-axis robotic arm governed by a closed-loop automatic repositioning algorithm. This system dynamically tracks the target stone using real-time 3D-PCM feedback, ensuring optimal acoustic coupling throughout the surgery. The results demonstrate that the integrated platform can accurately reconstruct surgical trajectories and provide intuitive, color-coded feedback on therapeutic efficacy. Collectively, this work provides a foundational engineering framework for the next generation of \"navigation-guided\" intelligent lithotripsy systems, promising to enhance surgical precision and patient safety in urology. </p>"]},{"key":"dc:embargo.terms","label":"Dc Embargo Terms","values":["24"]},{"key":"dc:title","label":"Title","values":["Three-dimensional Passive Cavitation Mapping during Laser Lithotripsy"]},{"key":"others:access_status","label":"Others Access Status","values":["embargo"]}]}],"canonical_facts":{"dc:contributor.advisor":["Yao, Junjie"],"dc:contributor.department":["Biomedical Engineering"],"dc:creator":["Li, Daiwei"],"dc:date.accessioned":["2026-09-22T18:42:09Z"],"dc:date.issued":["2026"],"dc:date.liftdate":["2028-09-22T18:42:09Z"],"dc:description.abstract":["<p>Laser lithotripsy (LL) is the gold-standard treatment for kidney stones; however, its clinical efficacy remains limited by the lack of real-time, quantitative feedback regarding the mechanical energy delivered to the stone. Currently, urologists rely primarily on subjective visual estimation through endoscopy, which is often obscured by debris and offers no depth-resolved information. This dissertation presents the development of an integrated three-dimensional passive cavitation mapping (3D-PCM) platform designed to provide non-invasive, real-time, and super-resolved monitoring of laser-induced cavitation activities.The research progresses through three major stages of innovation. First, a first-generation 3D Super-Resolution PCM (3D-SRPCM) framework was established. By implementing a radial symmetry localization algorithm, the system surpassed the acoustic diffraction limit, achieving sub-millimeter spatial precision. Through multimodal validation with high-speed imaging and optical coherence tomography (OCT), \"Accumulated Impact Pressure\" (Acc IP) was identified and validated as a robust quantitative biomarker ( γ =0.93) for predicting volumetric stone damage. Second, to address the computational demands of intraoperative monitoring, a GPU-accelerated beamforming architecture was developed. By optimizing sparse-matrix multiplication, the reconstruction latency was reduced to under 1 ms, enabling the spatiotemporal decoupling of complex cascading cavitation events. To further bridge the gap to clinical application, a custom 5 MHz, 256-element planar 2D matrix array was engineered. This second-generation hardware provides a deep field-of-view (FOV) exceeding 100 mm, ensuring consistent functional localization in deep-seated human tissues. Finally, the platform was translated into a pre-clinical swine model. To combat physiological motion, the transducer was integrated with a multi-axis robotic arm governed by a closed-loop automatic repositioning algorithm. This system dynamically tracks the target stone using real-time 3D-PCM feedback, ensuring optimal acoustic coupling throughout the surgery. The results demonstrate that the integrated platform can accurately reconstruct surgical trajectories and provide intuitive, color-coded feedback on therapeutic efficacy. Collectively, this work provides a foundational engineering framework for the next generation of \"navigation-guided\" intelligent lithotripsy systems, promising to enhance surgical precision and patient safety in urology. </p>"],"dc:embargo.terms":["24"],"dc:identifier.uri":["https://hdl.handle.net/10161/35711"],"dc:rights.uri":["https://creativecommons.org/licenses/by-nc-nd/4.0/"],"dc:subject":["Biomedical engineering"],"dc:title":["Three-dimensional Passive Cavitation Mapping during Laser Lithotripsy"],"dc:type":["Dissertation"],"others:access_status":["embargo"]},"updated_at":"2026-11-19T08:26:43Z"}