{"id":{"repo_id":"duke","oai_identifier":"oai:dukespace.lib.duke.edu:10161/5565"},"canonical_url":"https://search.ndltd.org/etd/duke/oai:dukespace.lib.duke.edu:10161/5565","repository":{"repo_id":"duke","name":"Duke University","base_url":"https://dukespace.lib.duke.edu/server/oai/request"},"display":{"title":"High Precision Measurement of the $^{19}$Ne Lifetime","abstract":"<p>The lifetime of $^{19}$Ne is an important parameter in precision tests of the Standard Model. Improvement in the uncertainty of experimental observables of this and other $T=\\frac{1}{2}$ mirror isotopes would allow for an extraction of</p><p>V$_{ud}$ at a similar precision to that obtained by superallowed $0^+\\rightarrow0^+$ Fermi decays. We report on a new high precision measurement of the lifetime of $^{19}$Ne, performed at the Kernfysich Versneller Instituut (KVI) in Groningen, the Netherlands. A 10.5 $\\frac{MeV}{A}$ $^{19}$F beam was used to produce $^{19}$Ne using inverse reaction kinematics in a H$_2$ gas target. Contaminant productions were eliminated using the TRI$\\mu$P magnetic isotope separator. The $^{19}$Ne beam was implanted into a thick aluminum tape, which was translated to a shielded detection region by a custom tape drive system. Collinear annihilation radiation from the emitted decay positrons were detected by two high purity germanium (HPGe) detectors. Event pulse waveforms were digitized and stored using a CAEN V1724 Digitizer. Systematic studies were performed to characterize rate-dependent data acquisition effects, diffusion, backgrounds, and contamination from the separator. We have obtained the result for the lifetime of $\\tau = 24.9344 \\pm 0.0073(stat) \\pm 0.0083(sys)$ seconds.</p>","abstract_html":"&lt;p&gt;The lifetime of <span class=\"etd-inline-math\"><sup>19</sup></span>Ne is an important parameter in precision tests of the Standard Model. Improvement in the uncertainty of experimental observables of this and other $T=\\frac{1}{2}$ mirror isotopes would allow for an extraction of&lt;/p&gt;&lt;p&gt;V<span class=\"etd-inline-math\"><sub>ud</sub></span> at a similar precision to that obtained by superallowed <span class=\"etd-inline-math\">0<sup>+</sup>\\rightarrow0<sup>+</sup></span> Fermi decays. We report on a new high precision measurement of the lifetime of <span class=\"etd-inline-math\"><sup>19</sup></span>Ne, performed at the Kernfysich Versneller Instituut (KVI) in Groningen, the Netherlands. A 10.5 $\\frac{MeV}{A}$ <span class=\"etd-inline-math\"><sup>19</sup></span>F beam was used to produce <span class=\"etd-inline-math\"><sup>19</sup></span>Ne using inverse reaction kinematics in a H<span class=\"etd-inline-math\"><sub>2</sub></span> gas target. Contaminant productions were eliminated using the TRI<span class=\"etd-inline-math\">&mu;</span>P magnetic isotope separator. The <span class=\"etd-inline-math\"><sup>19</sup></span>Ne beam was implanted into a thick aluminum tape, which was translated to a shielded detection region by a custom tape drive system. Collinear annihilation radiation from the emitted decay positrons were detected by two high purity germanium (HPGe) detectors. Event pulse waveforms were digitized and stored using a CAEN V1724 Digitizer. Systematic studies were performed to characterize rate-dependent data acquisition effects, diffusion, backgrounds, and contamination from the separator. We have obtained the result for the lifetime of $\\tau = 24.9344 \\pm 0.0073(stat) \\pm 0.0083(sys)$ seconds.&lt;/p&gt;","abstract_has_math":true,"creators":["Broussard, Leah"],"institution":null,"degree_name":null,"degree_level":null,"degree_discipline":null,"degree_department":"Physics","school":null,"contributors":[],"advisors":["Young, Albert R","Howell, Calvin R"],"committee_chairs":[],"committee_members":[],"year":2012,"date_issued":"2012","date_published":"2012","updated_at":"2026-11-19T08:25:01Z","subjects":["Nuclear physics","CKM unitarity","lifetime","Ne19","Vud"],"languages":[],"rights":[],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"https://hdl.handle.net/10161/5565","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"https://hdl.handle.net/10161/5565","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Aduke%3Aoai%3Adukespace.lib.duke.edu%3A10161%2F5565","prefix":"oai_dc"},"source_record":{"url":"https://dukespace.lib.duke.edu/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Adukespace.lib.duke.edu%3A10161%2F5565","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Young, Albert R","Howell, Calvin R"]},{"key":"dc:contributor.department","label":"Department","values":["Physics"]},{"key":"dc:creator","label":"Author","values":["Broussard, Leah"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2012-05-25T20:19:47Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2012-05-25T20:19:47Z"]},{"key":"dc:date.issued","label":"Date","values":["2012"]},{"key":"dc:type","label":"Dc Type","values":["Dissertation"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Nuclear physics","CKM unitarity","lifetime","Ne19","Vud"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://hdl.handle.net/10161/5565"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["<p>The lifetime of $^{19}$Ne is an important parameter in precision tests of the Standard Model. Improvement in the uncertainty of experimental observables of this and other $T=\\frac{1}{2}$ mirror isotopes would allow for an extraction of</p><p>V$_{ud}$ at a similar precision to that obtained by superallowed $0^+\\rightarrow0^+$ Fermi decays. We report on a new high precision measurement of the lifetime of $^{19}$Ne, performed at the Kernfysich Versneller Instituut (KVI) in Groningen, the Netherlands. A 10.5 $\\frac{MeV}{A}$ $^{19}$F beam was used to produce $^{19}$Ne using inverse reaction kinematics in a H$_2$ gas target. Contaminant productions were eliminated using the TRI$\\mu$P magnetic isotope separator. The $^{19}$Ne beam was implanted into a thick aluminum tape, which was translated to a shielded detection region by a custom tape drive system. Collinear annihilation radiation from the emitted decay positrons were detected by two high purity germanium (HPGe) detectors. Event pulse waveforms were digitized and stored using a CAEN V1724 Digitizer. Systematic studies were performed to characterize rate-dependent data acquisition effects, diffusion, backgrounds, and contamination from the separator. We have obtained the result for the lifetime of $\\tau = 24.9344 \\pm 0.0073(stat) \\pm 0.0083(sys)$ seconds.</p>"]},{"key":"dc:title","label":"Title","values":["High Precision Measurement of the $^{19}$Ne Lifetime"]},{"key":"others:access_status","label":"Others Access Status","values":["open.access"]}]}],"canonical_facts":{"dc:contributor.advisor":["Young, Albert R","Howell, Calvin R"],"dc:contributor.department":["Physics"],"dc:creator":["Broussard, Leah"],"dc:date.accessioned":["2012-05-25T20:19:47Z"],"dc:date.available":["2012-05-25T20:19:47Z"],"dc:date.issued":["2012"],"dc:description.abstract":["<p>The lifetime of $^{19}$Ne is an important parameter in precision tests of the Standard Model. Improvement in the uncertainty of experimental observables of this and other $T=\\frac{1}{2}$ mirror isotopes would allow for an extraction of</p><p>V$_{ud}$ at a similar precision to that obtained by superallowed $0^+\\rightarrow0^+$ Fermi decays. We report on a new high precision measurement of the lifetime of $^{19}$Ne, performed at the Kernfysich Versneller Instituut (KVI) in Groningen, the Netherlands. A 10.5 $\\frac{MeV}{A}$ $^{19}$F beam was used to produce $^{19}$Ne using inverse reaction kinematics in a H$_2$ gas target. Contaminant productions were eliminated using the TRI$\\mu$P magnetic isotope separator. The $^{19}$Ne beam was implanted into a thick aluminum tape, which was translated to a shielded detection region by a custom tape drive system. Collinear annihilation radiation from the emitted decay positrons were detected by two high purity germanium (HPGe) detectors. Event pulse waveforms were digitized and stored using a CAEN V1724 Digitizer. Systematic studies were performed to characterize rate-dependent data acquisition effects, diffusion, backgrounds, and contamination from the separator. We have obtained the result for the lifetime of $\\tau = 24.9344 \\pm 0.0073(stat) \\pm 0.0083(sys)$ seconds.</p>"],"dc:identifier.uri":["https://hdl.handle.net/10161/5565"],"dc:subject":["Nuclear physics","CKM unitarity","lifetime","Ne19","Vud"],"dc:title":["High Precision Measurement of the $^{19}$Ne Lifetime"],"dc:type":["Dissertation"],"others:access_status":["open.access"]},"updated_at":"2026-11-19T08:25:01Z"}