{"id":{"repo_id":"duquesne","oai_identifier":"oai:dsc.duq.edu:etd-2045"},"canonical_url":"https://search.ndltd.org/etd/duquesne/oai:dsc.duq.edu:etd-2045","repository":{"repo_id":"duquesne","name":"Duquesne","base_url":"https://dsc.duq.edu/do/oai/"},"display":{"title":"Methodology for Trace and Ultratrace Analysis of Primary Amines","abstract":"In the study of lipids, or \"lipidomics,\" methods for the separation and identification of specific trace compounds are highly sought. Microdroplet techniques have allowed for the ability to handle and detect these trace amounts. The use of low volumes allows for a decrease of the effective mean free path allowing chemical reactions to be carried out efficiently at lower concentrations by performing the reactions in microdroplets as opposed to bulk containers. Microdroplets created on microfluidic devices as segmented flow plugs have the advantage of efficient mixing and minimal dilution or dispersion relative to other nanoliter scale capillary reaction methods. The most sensitive detection techniques are needed for ultratrace analyses. Laser induced fluorescence (LIF) is the most attractive choice for ultratrace analysis. We show two methods for the derivatization and detection of primary amines with 3-(2-furoyl)quinoline-2-carboxaldehyde (FQCA) and with naphthalene-2,3-dicarboxaldehyde (NDA). The method has shown to be successful down to the sub-picomolar level in bulk solutions using an HPLC coupled with a fluorescence detector. The method has been transferred to microfluidic chips to explore the reaction and detection limits of the derivatized amines. Laser induced fluorescence (LIF) by a solid state blue violet laser was used as the detection method for the microfluidic platform. Successful usage of this methodology would allow for ultratrace detection of bioactive amines from small samples.","abstract_html":"In the study of lipids, or &quot;lipidomics,&quot; methods for the separation and identification of specific trace compounds are highly sought. Microdroplet techniques have allowed for the ability to handle and detect these trace amounts. The use of low volumes allows for a decrease of the effective mean free path allowing chemical reactions to be carried out efficiently at lower concentrations by performing the reactions in microdroplets as opposed to bulk containers. Microdroplets created on microfluidic devices as segmented flow plugs have the advantage of efficient mixing and minimal dilution or dispersion relative to other nanoliter scale capillary reaction methods. The most sensitive detection techniques are needed for ultratrace analyses. Laser induced fluorescence (LIF) is the most attractive choice for ultratrace analysis. We show two methods for the derivatization and detection of primary amines with 3-(2-furoyl)quinoline-2-carboxaldehyde (FQCA) and with naphthalene-2,3-dicarboxaldehyde (NDA). The method has shown to be successful down to the sub-picomolar level in bulk solutions using an HPLC coupled with a fluorescence detector. The method has been transferred to microfluidic chips to explore the reaction and detection limits of the derivatized amines. Laser induced fluorescence (LIF) by a solid state blue violet laser was used as the detection method for the microfluidic platform. Successful usage of this methodology would allow for ultratrace detection of bioactive amines from small samples.","abstract_has_math":false,"creators":["Pawlowski, Sean Christopher"],"institution":null,"degree_name":"PhD","degree_level":"Immediate Access","degree_discipline":"Chemistry and Biochemistry","degree_department":null,"school":null,"contributors":["Mitchell Johnson, Partha Basu","Michael Cascio","Bruce Beaver","David Gallaher"],"advisors":[],"committee_chairs":[],"committee_members":[],"year":null,"date_issued":"","date_published":null,"updated_at":"2026-11-19T07:52:21Z","subjects":["FQ","HPLC","laser induced fluorescence","LIF","microfluidics","NDA"],"languages":["English"],"rights":[],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"https://dsc.duq.edu/etd/1029","outbound_label":"Repository record","outbound_source":"dc:identifier","record_url":"https://dsc.duq.edu/etd/1029","record_label":"Repository record","record_kind":"record","record_source":"dc:identifier","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://dsc.duq.edu/do/oai/?verb=GetRecord&metadataPrefix=oai_etdms&identifier=oai%3Adsc.duq.edu%3Aetd-2045","prefix":"oai_etdms"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor","label":"Contributor","values":["Mitchell Johnson, Partha Basu","Michael Cascio","Bruce Beaver","David Gallaher"]},{"key":"dc:creator","label":"Author","values":["Pawlowski, Sean Christopher"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.available","label":"Dc Date Available","values":["2018-08-03T07:00:00Z"]},{"key":"dc:date.created","label":"Dc Date Created","values":["2014-01-01T08:00:00Z"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Chemistry and Biochemistry"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Immediate Access"]},{"key":"thesis:degree_name","label":"Degree Name","values":["PhD"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["FQ","HPLC","laser induced fluorescence","LIF","microfluidics","NDA"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language","label":"Dc Language","values":["English"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["https://dsc.duq.edu/etd/1029"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["In the study of lipids, or \"lipidomics,\" methods for the separation and identification of specific trace compounds are highly sought. Microdroplet techniques have allowed for the ability to handle and detect these trace amounts. The use of low volumes allows for a decrease of the effective mean free path allowing chemical reactions to be carried out efficiently at lower concentrations by performing the reactions in microdroplets as opposed to bulk containers. Microdroplets created on microfluidic devices as segmented flow plugs have the advantage of efficient mixing and minimal dilution or dispersion relative to other nanoliter scale capillary reaction methods. The most sensitive detection techniques are needed for ultratrace analyses. Laser induced fluorescence (LIF) is the most attractive choice for ultratrace analysis. We show two methods for the derivatization and detection of primary amines with 3-(2-furoyl)quinoline-2-carboxaldehyde (FQCA) and with naphthalene-2,3-dicarboxaldehyde (NDA). The method has shown to be successful down to the sub-picomolar level in bulk solutions using an HPLC coupled with a fluorescence detector. The method has been transferred to microfluidic chips to explore the reaction and detection limits of the derivatized amines. Laser induced fluorescence (LIF) by a solid state blue violet laser was used as the detection method for the microfluidic platform. Successful usage of this methodology would allow for ultratrace detection of bioactive amines from small samples."]},{"key":"dc:title","label":"Title","values":["Methodology for Trace and Ultratrace Analysis of Primary Amines"]}]}],"canonical_facts":{"dc:contributor":["Mitchell Johnson, Partha Basu","Michael Cascio","Bruce Beaver","David Gallaher"],"dc:creator":["Pawlowski, Sean Christopher"],"dc:date.available":["2018-08-03T07:00:00Z"],"dc:date.created":["2014-01-01T08:00:00Z"],"dc:description.abstract":["In the study of lipids, or \"lipidomics,\" methods for the separation and identification of specific trace compounds are highly sought. Microdroplet techniques have allowed for the ability to handle and detect these trace amounts. The use of low volumes allows for a decrease of the effective mean free path allowing chemical reactions to be carried out efficiently at lower concentrations by performing the reactions in microdroplets as opposed to bulk containers. Microdroplets created on microfluidic devices as segmented flow plugs have the advantage of efficient mixing and minimal dilution or dispersion relative to other nanoliter scale capillary reaction methods. The most sensitive detection techniques are needed for ultratrace analyses. Laser induced fluorescence (LIF) is the most attractive choice for ultratrace analysis. We show two methods for the derivatization and detection of primary amines with 3-(2-furoyl)quinoline-2-carboxaldehyde (FQCA) and with naphthalene-2,3-dicarboxaldehyde (NDA). The method has shown to be successful down to the sub-picomolar level in bulk solutions using an HPLC coupled with a fluorescence detector. The method has been transferred to microfluidic chips to explore the reaction and detection limits of the derivatized amines. Laser induced fluorescence (LIF) by a solid state blue violet laser was used as the detection method for the microfluidic platform. Successful usage of this methodology would allow for ultratrace detection of bioactive amines from small samples."],"dc:identifier":["https://dsc.duq.edu/etd/1029"],"dc:language":["English"],"dc:subject":["FQ","HPLC","laser induced fluorescence","LIF","microfluidics","NDA"],"dc:title":["Methodology for Trace and Ultratrace Analysis of Primary Amines"],"thesis:degree_discipline":["Chemistry and Biochemistry"],"thesis:degree_level":["Immediate Access"],"thesis:degree_name":["PhD"]},"updated_at":"2026-11-19T07:52:21Z"}