{"id":{"repo_id":"duquesne","oai_identifier":"oai:dsc.duq.edu:etd-3273"},"canonical_url":"https://search.ndltd.org/etd/duquesne/oai:dsc.duq.edu:etd-3273","repository":{"repo_id":"duquesne","name":"Duquesne","base_url":"https://dsc.duq.edu/do/oai/"},"display":{"title":"ADVANCEMENT OF ITERATIVE OPTIMIZATION TECHNOLOGY ALGORITHMS TOWARD CALIBRATION-FREE PROCESS ANALYTICAL TECHNOLOGY APPLICATIONS","abstract":"The expansion of spectroscopic process analytical technology (PAT) tools within the pharmaceutical industry has the potential to elevate the current state-of-the-art of pharmaceutical manufacturing by offering opportunities for reduced quality testing times, enhanced process control, and greater production flexibility. Spectroscopic PAT tools are dependent on multivariate models to extract the relevant information from the spectral outputs. However, there is a substantial calibration burden for developing and maintaining these multivariate models that discourages the application of PAT, despite the encouragement from regulators. This has led to an interest in calibration-free methods such as iterative optimization technology (IOT) for spectroscopic PAT that have a substantially reduced calibration burden. The application of IOT algorithms to spectroscopic PAT tools by the pharmaceutical industry is inhibited by two major limitations. First, generalized model diagnostics are lacking for IOT algorithms. Second, IOT algorithms have limited prediction robustness when challenged by chemical and process variations. Current strategies available within the scientific literature to improve prediction accuracy and robustness of IOT algorithms unfortunately require appropriate . This moves away from the calibration-free intentions of the base IOT algorithm. To address these limitations and advance IOT algorithms, this dissertation proposes the use of the net analyte signal (NAS) vector as a basis for a model diagnostic and calibration-free wavelength selection method that are both applicable to IOT algorithms. This dissertation successfully advances the state of IOT algorithms with the introduction of the NAS theta (NAS-T) model diagnostic and the calibration-free wavelength angle mapper (WAM) wavelength selection strategy.","abstract_html":"The expansion of spectroscopic process analytical technology (PAT) tools within the pharmaceutical industry has the potential to elevate the current state-of-the-art of pharmaceutical manufacturing by offering opportunities for reduced quality testing times, enhanced process control, and greater production flexibility. Spectroscopic PAT tools are dependent on multivariate models to extract the relevant information from the spectral outputs. However, there is a substantial calibration burden for developing and maintaining these multivariate models that discourages the application of PAT, despite the encouragement from regulators. This has led to an interest in calibration-free methods such as iterative optimization technology (IOT) for spectroscopic PAT that have a substantially reduced calibration burden. The application of IOT algorithms to spectroscopic PAT tools by the pharmaceutical industry is inhibited by two major limitations. First, generalized model diagnostics are lacking for IOT algorithms. Second, IOT algorithms have limited prediction robustness when challenged by chemical and process variations. Current strategies available within the scientific literature to improve prediction accuracy and robustness of IOT algorithms unfortunately require appropriate . This moves away from the calibration-free intentions of the base IOT algorithm. To address these limitations and advance IOT algorithms, this dissertation proposes the use of the net analyte signal (NAS) vector as a basis for a model diagnostic and calibration-free wavelength selection method that are both applicable to IOT algorithms. This dissertation successfully advances the state of IOT algorithms with the introduction of the NAS theta (NAS-T) model diagnostic and the calibration-free wavelength angle mapper (WAM) wavelength selection strategy.","abstract_has_math":false,"creators":["Rish, Adam"],"institution":null,"degree_name":"PhD","degree_level":"One-year Embargo","degree_discipline":"Pharmaceutics","degree_department":null,"school":null,"contributors":["Carl A. Anderson, PhD","James K. Drennen, III, PhD","Kevin Tidgewell, PhD","Rehana K. Leak, PhD","Alexandre Ambrogelly, PhD"],"advisors":[],"committee_chairs":[],"committee_members":[],"year":null,"date_issued":"","date_published":null,"updated_at":"2026-11-19T07:52:38Z","subjects":["chemometrics","process analytical technology (PAT)","iterative optimization technology (IOT)","net analyte signal (NAS)","model diagnostics","wavelength selection","calibration-free","Analytical Chemistry","Applied Statistics","Data Science","Multivariate Analysis","Statistical Models"],"languages":["English"],"rights":[],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"https://dsc.duq.edu/etd/2350","outbound_label":"Repository record","outbound_source":"dc:identifier","record_url":"https://dsc.duq.edu/etd/2350","record_label":"Repository record","record_kind":"record","record_source":"dc:identifier","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://dsc.duq.edu/do/oai/?verb=GetRecord&metadataPrefix=oai_etdms&identifier=oai%3Adsc.duq.edu%3Aetd-3273","prefix":"oai_etdms"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor","label":"Contributor","values":["Carl A. Anderson, PhD","James K. Drennen, III, PhD","Kevin Tidgewell, PhD","Rehana K. Leak, PhD","Alexandre Ambrogelly, PhD"]},{"key":"dc:creator","label":"Author","values":["Rish, Adam"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.available","label":"Dc Date Available","values":["2025-05-10T07:00:00Z"]},{"key":"dc:date.created","label":"Dc Date Created","values":["2024-05-01T07:00:00Z"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Pharmaceutics"]},{"key":"thesis:degree_level","label":"Degree Level","values":["One-year Embargo"]},{"key":"thesis:degree_name","label":"Degree Name","values":["PhD"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["chemometrics","process analytical technology (PAT)","iterative optimization technology (IOT)","net analyte signal (NAS)","model diagnostics","wavelength selection","calibration-free","Analytical Chemistry","Applied Statistics","Data Science","Multivariate Analysis","Statistical Models"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language","label":"Dc Language","values":["English"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["https://dsc.duq.edu/etd/2350"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["The expansion of spectroscopic process analytical technology (PAT) tools within the pharmaceutical industry has the potential to elevate the current state-of-the-art of pharmaceutical manufacturing by offering opportunities for reduced quality testing times, enhanced process control, and greater production flexibility. Spectroscopic PAT tools are dependent on multivariate models to extract the relevant information from the spectral outputs. However, there is a substantial calibration burden for developing and maintaining these multivariate models that discourages the application of PAT, despite the encouragement from regulators. This has led to an interest in calibration-free methods such as iterative optimization technology (IOT) for spectroscopic PAT that have a substantially reduced calibration burden. The application of IOT algorithms to spectroscopic PAT tools by the pharmaceutical industry is inhibited by two major limitations. First, generalized model diagnostics are lacking for IOT algorithms. Second, IOT algorithms have limited prediction robustness when challenged by chemical and process variations. Current strategies available within the scientific literature to improve prediction accuracy and robustness of IOT algorithms unfortunately require appropriate . This moves away from the calibration-free intentions of the base IOT algorithm. To address these limitations and advance IOT algorithms, this dissertation proposes the use of the net analyte signal (NAS) vector as a basis for a model diagnostic and calibration-free wavelength selection method that are both applicable to IOT algorithms. This dissertation successfully advances the state of IOT algorithms with the introduction of the NAS theta (NAS-T) model diagnostic and the calibration-free wavelength angle mapper (WAM) wavelength selection strategy."]},{"key":"dc:title","label":"Title","values":["ADVANCEMENT OF ITERATIVE OPTIMIZATION TECHNOLOGY ALGORITHMS TOWARD CALIBRATION-FREE PROCESS ANALYTICAL TECHNOLOGY APPLICATIONS"]}]}],"canonical_facts":{"dc:contributor":["Carl A. Anderson, PhD","James K. Drennen, III, PhD","Kevin Tidgewell, PhD","Rehana K. Leak, PhD","Alexandre Ambrogelly, PhD"],"dc:creator":["Rish, Adam"],"dc:date.available":["2025-05-10T07:00:00Z"],"dc:date.created":["2024-05-01T07:00:00Z"],"dc:description.abstract":["The expansion of spectroscopic process analytical technology (PAT) tools within the pharmaceutical industry has the potential to elevate the current state-of-the-art of pharmaceutical manufacturing by offering opportunities for reduced quality testing times, enhanced process control, and greater production flexibility. Spectroscopic PAT tools are dependent on multivariate models to extract the relevant information from the spectral outputs. However, there is a substantial calibration burden for developing and maintaining these multivariate models that discourages the application of PAT, despite the encouragement from regulators. This has led to an interest in calibration-free methods such as iterative optimization technology (IOT) for spectroscopic PAT that have a substantially reduced calibration burden. The application of IOT algorithms to spectroscopic PAT tools by the pharmaceutical industry is inhibited by two major limitations. First, generalized model diagnostics are lacking for IOT algorithms. Second, IOT algorithms have limited prediction robustness when challenged by chemical and process variations. Current strategies available within the scientific literature to improve prediction accuracy and robustness of IOT algorithms unfortunately require appropriate . This moves away from the calibration-free intentions of the base IOT algorithm. To address these limitations and advance IOT algorithms, this dissertation proposes the use of the net analyte signal (NAS) vector as a basis for a model diagnostic and calibration-free wavelength selection method that are both applicable to IOT algorithms. This dissertation successfully advances the state of IOT algorithms with the introduction of the NAS theta (NAS-T) model diagnostic and the calibration-free wavelength angle mapper (WAM) wavelength selection strategy."],"dc:identifier":["https://dsc.duq.edu/etd/2350"],"dc:language":["English"],"dc:subject":["chemometrics","process analytical technology (PAT)","iterative optimization technology (IOT)","net analyte signal (NAS)","model diagnostics","wavelength selection","calibration-free","Analytical Chemistry","Applied Statistics","Data Science","Multivariate Analysis","Statistical Models"],"dc:title":["ADVANCEMENT OF ITERATIVE OPTIMIZATION TECHNOLOGY ALGORITHMS TOWARD CALIBRATION-FREE PROCESS ANALYTICAL TECHNOLOGY APPLICATIONS"],"thesis:degree_discipline":["Pharmaceutics"],"thesis:degree_level":["One-year Embargo"],"thesis:degree_name":["PhD"]},"updated_at":"2026-11-19T07:52:38Z"}