{"id":{"repo_id":"duquesne","oai_identifier":"oai:dsc.duq.edu:etd-3374"},"canonical_url":"https://search.ndltd.org/etd/duquesne/oai:dsc.duq.edu:etd-3374","repository":{"repo_id":"duquesne","name":"Duquesne","base_url":"https://dsc.duq.edu/do/oai/"},"display":{"title":"Efficient Development of Density-Insensitive Near-Infrared Methods for In-Line Drug Content Monitoring in Continuous Powder Streams","abstract":"A well-defined action plan to respond effectively to sudden changes in product demand is critical for preventing drug shortages within the pharmaceutical industry. An effective way to increase the output of a continuous manufacturing (CM) process is through flow rate adjustments. However, robust analytical methods must be in place to ensure consistent analytical performance across varying flow rates. Existing approaches for mitigating the physical effects of flow rate on Near-Infrared (NIR) measurements are often burdensome. Thus, efficient robust modeling strategies that reduce the current calibration burden and ensure model insensitivity to the physical variations in CM systems are needed. In this dissertation, powder density is identified as an underlying source of spectral variance due to flow rate and used to develop material-sparing calibration and pure component methods with enhanced robustness to scale (i.e. flow rate). The in-line characterization of density variation for continuous powder streams is facilitated by a process analytical technology method consisting of live imaging and dynamic mass characterization. This work proposes a new robust modeling platform based on a data collection strategy for the development of density-insensitive NIR calibrations for drug content. Additionally, a novel extended version of the base iterative optimization technology (IOT) algorithm that includes density information is proposed as a minimal calibration approach for enhancing the flow rate robustness of IOT models. The methods proposed in this dissertation offer a promising alternative to burdensome robust modeling techniques. They aim to ensure consistent NIR analytical performance across variable production scales, while also achieving material efficiency.","abstract_html":"A well-defined action plan to respond effectively to sudden changes in product demand is critical for preventing drug shortages within the pharmaceutical industry. An effective way to increase the output of a continuous manufacturing (CM) process is through flow rate adjustments. However, robust analytical methods must be in place to ensure consistent analytical performance across varying flow rates. Existing approaches for mitigating the physical effects of flow rate on Near-Infrared (NIR) measurements are often burdensome. Thus, efficient robust modeling strategies that reduce the current calibration burden and ensure model insensitivity to the physical variations in CM systems are needed. In this dissertation, powder density is identified as an underlying source of spectral variance due to flow rate and used to develop material-sparing calibration and pure component methods with enhanced robustness to scale (i.e. flow rate). The in-line characterization of density variation for continuous powder streams is facilitated by a process analytical technology method consisting of live imaging and dynamic mass characterization. This work proposes a new robust modeling platform based on a data collection strategy for the development of density-insensitive NIR calibrations for drug content. Additionally, a novel extended version of the base iterative optimization technology (IOT) algorithm that includes density information is proposed as a minimal calibration approach for enhancing the flow rate robustness of IOT models. The methods proposed in this dissertation offer a promising alternative to burdensome robust modeling techniques. They aim to ensure consistent NIR analytical performance across variable production scales, while also achieving material efficiency.","abstract_has_math":false,"creators":["Velez-Silva, Natasha L."],"institution":null,"degree_name":"PhD","degree_level":"One-year Embargo","degree_discipline":"Pharmaceutics","degree_department":null,"school":null,"contributors":["Carl A. Anderson","James K. Drennen, III","Ira S. Buckner","Zhenqi Shi","Steven Doherty"],"advisors":[],"committee_chairs":[],"committee_members":[],"year":null,"date_issued":"","date_published":null,"updated_at":"2026-11-19T07:52:38Z","subjects":["Near-Infrared Spectroscopy","Process Analytical Technology","Model Robustness","Calibration Burden","PLS Regression","Iterative Optimization Technology","Continuous Manufacturing","Powder Density","Powder Flow","Multivariate Analysis","Pharmaceutics and Drug Design"],"languages":["English"],"rights":[],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"https://dsc.duq.edu/etd/2406","outbound_label":"Repository record","outbound_source":"dc:identifier","record_url":"https://dsc.duq.edu/etd/2406","record_label":"Repository record","record_kind":"record","record_source":"dc:identifier","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://dsc.duq.edu/do/oai/?verb=GetRecord&metadataPrefix=oai_etdms&identifier=oai%3Adsc.duq.edu%3Aetd-3374","prefix":"oai_etdms"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor","label":"Contributor","values":["Carl A. Anderson","James K. Drennen, III","Ira S. Buckner","Zhenqi Shi","Steven Doherty"]},{"key":"dc:creator","label":"Author","values":["Velez-Silva, Natasha L."]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.available","label":"Dc Date Available","values":["2026-01-31T08:00:00Z"]},{"key":"dc:date.created","label":"Dc Date Created","values":["2024-12-20T08:00:00Z"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Pharmaceutics"]},{"key":"thesis:degree_level","label":"Degree Level","values":["One-year Embargo"]},{"key":"thesis:degree_name","label":"Degree Name","values":["PhD"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Near-Infrared Spectroscopy","Process Analytical Technology","Model Robustness","Calibration Burden","PLS Regression","Iterative Optimization Technology","Continuous Manufacturing","Powder Density","Powder Flow","Multivariate Analysis","Pharmaceutics and Drug Design"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language","label":"Dc Language","values":["English"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["https://dsc.duq.edu/etd/2406"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["A well-defined action plan to respond effectively to sudden changes in product demand is critical for preventing drug shortages within the pharmaceutical industry. An effective way to increase the output of a continuous manufacturing (CM) process is through flow rate adjustments. However, robust analytical methods must be in place to ensure consistent analytical performance across varying flow rates. Existing approaches for mitigating the physical effects of flow rate on Near-Infrared (NIR) measurements are often burdensome. Thus, efficient robust modeling strategies that reduce the current calibration burden and ensure model insensitivity to the physical variations in CM systems are needed. In this dissertation, powder density is identified as an underlying source of spectral variance due to flow rate and used to develop material-sparing calibration and pure component methods with enhanced robustness to scale (i.e. flow rate). The in-line characterization of density variation for continuous powder streams is facilitated by a process analytical technology method consisting of live imaging and dynamic mass characterization. This work proposes a new robust modeling platform based on a data collection strategy for the development of density-insensitive NIR calibrations for drug content. Additionally, a novel extended version of the base iterative optimization technology (IOT) algorithm that includes density information is proposed as a minimal calibration approach for enhancing the flow rate robustness of IOT models. The methods proposed in this dissertation offer a promising alternative to burdensome robust modeling techniques. They aim to ensure consistent NIR analytical performance across variable production scales, while also achieving material efficiency."]},{"key":"dc:title","label":"Title","values":["Efficient Development of Density-Insensitive Near-Infrared Methods for In-Line Drug Content Monitoring in Continuous Powder Streams"]}]}],"canonical_facts":{"dc:contributor":["Carl A. Anderson","James K. Drennen, III","Ira S. Buckner","Zhenqi Shi","Steven Doherty"],"dc:creator":["Velez-Silva, Natasha L."],"dc:date.available":["2026-01-31T08:00:00Z"],"dc:date.created":["2024-12-20T08:00:00Z"],"dc:description.abstract":["A well-defined action plan to respond effectively to sudden changes in product demand is critical for preventing drug shortages within the pharmaceutical industry. An effective way to increase the output of a continuous manufacturing (CM) process is through flow rate adjustments. However, robust analytical methods must be in place to ensure consistent analytical performance across varying flow rates. Existing approaches for mitigating the physical effects of flow rate on Near-Infrared (NIR) measurements are often burdensome. Thus, efficient robust modeling strategies that reduce the current calibration burden and ensure model insensitivity to the physical variations in CM systems are needed. In this dissertation, powder density is identified as an underlying source of spectral variance due to flow rate and used to develop material-sparing calibration and pure component methods with enhanced robustness to scale (i.e. flow rate). The in-line characterization of density variation for continuous powder streams is facilitated by a process analytical technology method consisting of live imaging and dynamic mass characterization. This work proposes a new robust modeling platform based on a data collection strategy for the development of density-insensitive NIR calibrations for drug content. Additionally, a novel extended version of the base iterative optimization technology (IOT) algorithm that includes density information is proposed as a minimal calibration approach for enhancing the flow rate robustness of IOT models. The methods proposed in this dissertation offer a promising alternative to burdensome robust modeling techniques. They aim to ensure consistent NIR analytical performance across variable production scales, while also achieving material efficiency."],"dc:identifier":["https://dsc.duq.edu/etd/2406"],"dc:language":["English"],"dc:subject":["Near-Infrared Spectroscopy","Process Analytical Technology","Model Robustness","Calibration Burden","PLS Regression","Iterative Optimization Technology","Continuous Manufacturing","Powder Density","Powder Flow","Multivariate Analysis","Pharmaceutics and Drug Design"],"dc:title":["Efficient Development of Density-Insensitive Near-Infrared Methods for In-Line Drug Content Monitoring in Continuous Powder Streams"],"thesis:degree_discipline":["Pharmaceutics"],"thesis:degree_level":["One-year Embargo"],"thesis:degree_name":["PhD"]},"updated_at":"2026-11-19T07:52:38Z"}