{"id":{"repo_id":"durham","oai_identifier":"oai:etheses.durham.ac.uk:13241"},"canonical_url":"https://search.ndltd.org/etd/durham/oai:etheses.durham.ac.uk:13241","repository":{"repo_id":"durham","name":"Durham University","base_url":"http://etheses.dur.ac.uk/cgi/oai2"},"display":{"title":"An Analysis of Uncertainty for Dose Estimation through the γ-H2AX Assay","abstract":"Currently, the primary biomarker for radiation biodosimetry is the dicentric chromosome. However, the γ-H2AX histone is an alternative assay that is less labour-intensive. Blood samples can be taken more quickly than for the dicentric biomarker, and a larger number of samples can be handled within a given time frame. In this thesis, we discuss several statistical techniques for how to handle scored γ-H2AX foci data. We then apply these techniques to two datasets from Public Health England, using one to demonstrate techniques, and the second to check that the dose-response curve calculation and dose estimation techniques work. Throughout we choose to fit quasi-Poisson models instead of Poisson ones to account for overdispersion present within the foci count data. After fitting both linear and quadratic dose-response curves we create controls to validate the curves, using a reference sampling ratio to scale them if necessary. By calculating the uncertainty we show why linear fits are preferable to quadratic ones. We finally compare our linear dose-response curves from both datasets for multiple timepoints with pre-existing ones from the literature to see how they compare and what conclusions can be drawn about dose-response curves for this assay in general.","abstract_html":"Currently, the primary biomarker for radiation biodosimetry is the dicentric chromosome. However, the γ-H2AX histone is an alternative assay that is less labour-intensive. Blood samples can be taken more quickly than for the dicentric biomarker, and a larger number of samples can be handled within a given time frame. In this thesis, we discuss several statistical techniques for how to handle scored γ-H2AX foci data. We then apply these techniques to two datasets from Public Health England, using one to demonstrate techniques, and the second to check that the dose-response curve calculation and dose estimation techniques work. Throughout we choose to fit quasi-Poisson models instead of Poisson ones to account for overdispersion present within the foci count data. After fitting both linear and quadratic dose-response curves we create controls to validate the curves, using a reference sampling ratio to scale them if necessary. By calculating the uncertainty we show why linear fits are preferable to quadratic ones. We finally compare our linear dose-response curves from both datasets for multiple timepoints with pre-existing ones from the literature to see how they compare and what conclusions can be drawn about dose-response curves for this assay in general.","abstract_has_math":false,"creators":["Sales, Rachel Mary"],"institution":"Durham University","degree_name":"Masters","degree_level":"masters","degree_discipline":null,"degree_department":null,"school":null,"contributors":[],"advisors":[],"committee_chairs":[],"committee_members":[],"year":2019,"date_issued":"2019","date_published":"2019","updated_at":"2026-11-26T04:25:17Z","subjects":[],"languages":["eng"],"rights":[],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"https://etheses.durham.ac.uk/id/eprint/13241/","outbound_label":"Repository record","outbound_source":"dc:identifier.uri","record_url":"https://etheses.durham.ac.uk/id/eprint/13241/","record_label":"Repository record","record_kind":"record","record_source":"dc:identifier.uri","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Adurham%3Aoai%3Aetheses.durham.ac.uk%3A13241","prefix":"oai_dc"},"source_record":{"url":"http://etheses.dur.ac.uk/cgi/oai2?verb=GetRecord&metadataPrefix=uketd_dc&identifier=oai%3Aetheses.durham.ac.uk%3A13241","prefix":"uketd_dc"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:creator","label":"Author","values":["Sales, Rachel Mary"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["2019"]},{"key":"dc:date.issued","label":"Date","values":["2019"]},{"key":"dc:publisher.department","label":"Dc Publisher Department","values":["Mathematical Sciences, Department of"]},{"key":"dc:publisher.institution","label":"Dc Publisher Institution","values":["Durham University"]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]},{"key":"dc:type.qualificationlevel","label":"Dc Type Qualificationlevel","values":["masters"]},{"key":"dc:type.qualificationname","label":"Dc Type Qualificationname","values":["Masters"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.dcterms_iso639_2","label":"Language (ISO 639-2)","values":["eng"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://etheses.durham.ac.uk/id/eprint/13241/"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["Currently, the primary biomarker for radiation biodosimetry is the dicentric chromosome. However, the γ-H2AX histone is an alternative assay that is less labour-intensive. Blood samples can be taken more quickly than for the dicentric biomarker, and a larger number of samples can be handled within a given time frame. In this thesis, we discuss several statistical techniques for how to handle scored γ-H2AX foci data. We then apply these techniques to two datasets from Public Health England, using one to demonstrate techniques, and the second to check that the dose-response curve calculation and dose estimation techniques work. Throughout we choose to fit quasi-Poisson models instead of Poisson ones to account for overdispersion present within the foci count data. After fitting both linear and quadratic dose-response curves we create controls to validate the curves, using a reference sampling ratio to scale them if necessary. By calculating the uncertainty we show why linear fits are preferable to quadratic ones. We finally compare our linear dose-response curves from both datasets for multiple timepoints with pre-existing ones from the literature to see how they compare and what conclusions can be drawn about dose-response curves for this assay in general."]},{"key":"dc:format","label":"Dc Format","values":["text"]},{"key":"dcterms:accessrights","label":"Dcterms Accessrights","values":["public"]},{"key":"dc:title","label":"Title","values":["An Analysis of Uncertainty for Dose Estimation through the γ-H2AX Assay"]}]}],"canonical_facts":{"dc:creator":["Sales, Rachel Mary"],"dc:date":["2019"],"dc:date.issued":["2019"],"dc:description.abstract":["Currently, the primary biomarker for radiation biodosimetry is the dicentric chromosome. However, the γ-H2AX histone is an alternative assay that is less labour-intensive. Blood samples can be taken more quickly than for the dicentric biomarker, and a larger number of samples can be handled within a given time frame. In this thesis, we discuss several statistical techniques for how to handle scored γ-H2AX foci data. We then apply these techniques to two datasets from Public Health England, using one to demonstrate techniques, and the second to check that the dose-response curve calculation and dose estimation techniques work. Throughout we choose to fit quasi-Poisson models instead of Poisson ones to account for overdispersion present within the foci count data. After fitting both linear and quadratic dose-response curves we create controls to validate the curves, using a reference sampling ratio to scale them if necessary. By calculating the uncertainty we show why linear fits are preferable to quadratic ones. We finally compare our linear dose-response curves from both datasets for multiple timepoints with pre-existing ones from the literature to see how they compare and what conclusions can be drawn about dose-response curves for this assay in general."],"dc:format":["text"],"dc:identifier.uri":["https://etheses.durham.ac.uk/id/eprint/13241/"],"dc:language.dcterms_iso639_2":["eng"],"dc:publisher.department":["Mathematical Sciences, Department of"],"dc:publisher.institution":["Durham University"],"dcterms:accessrights":["public"],"dc:title":["An Analysis of Uncertainty for Dose Estimation through the γ-H2AX Assay"],"dc:type":["Thesis"],"dc:type.qualificationlevel":["masters"],"dc:type.qualificationname":["Masters"]},"updated_at":"2026-11-26T04:25:17Z"}