{"id":{"repo_id":"durham","oai_identifier":"oai:etheses.durham.ac.uk:15014"},"canonical_url":"https://search.ndltd.org/etd/durham/oai:etheses.durham.ac.uk:15014","repository":{"repo_id":"durham","name":"Durham University","base_url":"http://etheses.dur.ac.uk/cgi/oai2"},"display":{"title":"Combined Photovoltaic-Thermal System with Phase Change Material Thermal Storage Tank for Decarbonising Domestic Buildings","abstract":"Utilizing solar energy to replace fossil fuels for residential energy supply offers a promising strategy for decarbonizing domestic buildings. This study designed a Photovoltaic-Thermal system assisted by a Heat Pump and integrated with a Phase Change Material thermal storage tank (PVT-PCM) for residential heating and hot water supply. To analyze the performance of the solar energy supply and storage system, a thermal consumption model of a conventional house was built and combined with the PVT-PCM system model on the TRNSYS software. When using a 61.75 m2 PVT panel and 1.35m3 PVT float tank, along with a 0.45 m3 DHW tank, the system can cover 96% of the conventional house's thermal load in January and December, and fully meet the house's thermal needs in other months, maintaining an average temperature of 18.8 °C. The integration of a 0.382 m3 PCM tank has a limited impact on the system's thermal supply performance. However, when the PCM can be fully charged and has a release rate of 63.8%, it can lead to an 18.8% increase in thermal supply, a 1.5% improvement in the heat pump's Coefficient of Performance (COP), and an energy density of the PCM tank that's 17.8% higher than that of the water tank.","abstract_html":"Utilizing solar energy to replace fossil fuels for residential energy supply offers a promising strategy for decarbonizing domestic buildings. This study designed a Photovoltaic-Thermal system assisted by a Heat Pump and integrated with a Phase Change Material thermal storage tank (PVT-PCM) for residential heating and hot water supply. To analyze the performance of the solar energy supply and storage system, a thermal consumption model of a conventional house was built and combined with the PVT-PCM system model on the TRNSYS software. When using a 61.75 m2 PVT panel and 1.35m3 PVT float tank, along with a 0.45 m3 DHW tank, the system can cover 96% of the conventional house&#x27;s thermal load in January and December, and fully meet the house&#x27;s thermal needs in other months, maintaining an average temperature of 18.8 °C. The integration of a 0.382 m3 PCM tank has a limited impact on the system&#x27;s thermal supply performance. However, when the PCM can be fully charged and has a release rate of 63.8%, it can lead to an 18.8% increase in thermal supply, a 1.5% improvement in the heat pump&#x27;s Coefficient of Performance (COP), and an energy density of the PCM tank that&#x27;s 17.8% higher than that of the water tank.","abstract_has_math":false,"creators":["Wang, Chenjue"],"institution":"Durham University","degree_name":"Masters","degree_level":"masters","degree_discipline":null,"degree_department":null,"school":null,"contributors":[],"advisors":[],"committee_chairs":[],"committee_members":[],"year":2023,"date_issued":"2023","date_published":"2023","updated_at":"2026-11-26T04:25:53Z","subjects":[],"languages":["eng"],"rights":[],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"https://etheses.durham.ac.uk/id/eprint/15014/","outbound_label":"Repository record","outbound_source":"dc:identifier.uri","record_url":"https://etheses.durham.ac.uk/id/eprint/15014/","record_label":"Repository record","record_kind":"record","record_source":"dc:identifier.uri","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Adurham%3Aoai%3Aetheses.durham.ac.uk%3A15014","prefix":"oai_dc"},"source_record":{"url":"http://etheses.dur.ac.uk/cgi/oai2?verb=GetRecord&metadataPrefix=uketd_dc&identifier=oai%3Aetheses.durham.ac.uk%3A15014","prefix":"uketd_dc"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:creator","label":"Author","values":["Wang, Chenjue"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["2023"]},{"key":"dc:date.issued","label":"Date","values":["2023"]},{"key":"dc:publisher.department","label":"Dc Publisher Department","values":["Engineering, Department of"]},{"key":"dc:publisher.institution","label":"Dc Publisher Institution","values":["Durham University"]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]},{"key":"dc:type.qualificationlevel","label":"Dc Type Qualificationlevel","values":["masters"]},{"key":"dc:type.qualificationname","label":"Dc Type Qualificationname","values":["Masters"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.dcterms_iso639_2","label":"Language (ISO 639-2)","values":["eng"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://etheses.durham.ac.uk/id/eprint/15014/"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["Utilizing solar energy to replace fossil fuels for residential energy supply offers a promising strategy for decarbonizing domestic buildings. This study designed a Photovoltaic-Thermal system assisted by a Heat Pump and integrated with a Phase Change Material thermal storage tank (PVT-PCM) for residential heating and hot water supply. To analyze the performance of the solar energy supply and storage system, a thermal consumption model of a conventional house was built and combined with the PVT-PCM system model on the TRNSYS software. When using a 61.75 m2 PVT panel and 1.35m3 PVT float tank, along with a 0.45 m3 DHW tank, the system can cover 96% of the conventional house's thermal load in January and December, and fully meet the house's thermal needs in other months, maintaining an average temperature of 18.8 °C. The integration of a 0.382 m3 PCM tank has a limited impact on the system's thermal supply performance. However, when the PCM can be fully charged and has a release rate of 63.8%, it can lead to an 18.8% increase in thermal supply, a 1.5% improvement in the heat pump's Coefficient of Performance (COP), and an energy density of the PCM tank that's 17.8% higher than that of the water tank."]},{"key":"dc:format","label":"Dc Format","values":["text"]},{"key":"dcterms:accessrights","label":"Dcterms Accessrights","values":["public"]},{"key":"dc:title","label":"Title","values":["Combined Photovoltaic-Thermal System with Phase Change Material Thermal Storage Tank for Decarbonising Domestic Buildings"]}]}],"canonical_facts":{"dc:creator":["Wang, Chenjue"],"dc:date":["2023"],"dc:date.issued":["2023"],"dc:description.abstract":["Utilizing solar energy to replace fossil fuels for residential energy supply offers a promising strategy for decarbonizing domestic buildings. This study designed a Photovoltaic-Thermal system assisted by a Heat Pump and integrated with a Phase Change Material thermal storage tank (PVT-PCM) for residential heating and hot water supply. To analyze the performance of the solar energy supply and storage system, a thermal consumption model of a conventional house was built and combined with the PVT-PCM system model on the TRNSYS software. When using a 61.75 m2 PVT panel and 1.35m3 PVT float tank, along with a 0.45 m3 DHW tank, the system can cover 96% of the conventional house's thermal load in January and December, and fully meet the house's thermal needs in other months, maintaining an average temperature of 18.8 °C. The integration of a 0.382 m3 PCM tank has a limited impact on the system's thermal supply performance. However, when the PCM can be fully charged and has a release rate of 63.8%, it can lead to an 18.8% increase in thermal supply, a 1.5% improvement in the heat pump's Coefficient of Performance (COP), and an energy density of the PCM tank that's 17.8% higher than that of the water tank."],"dc:format":["text"],"dc:identifier.uri":["https://etheses.durham.ac.uk/id/eprint/15014/"],"dc:language.dcterms_iso639_2":["eng"],"dc:publisher.department":["Engineering, Department of"],"dc:publisher.institution":["Durham University"],"dcterms:accessrights":["public"],"dc:title":["Combined Photovoltaic-Thermal System with Phase Change Material Thermal Storage Tank for Decarbonising Domestic Buildings"],"dc:type":["Thesis"],"dc:type.qualificationlevel":["masters"],"dc:type.qualificationname":["Masters"]},"updated_at":"2026-11-26T04:25:53Z"}