{"id":{"repo_id":"durham","oai_identifier":"oai:etheses.durham.ac.uk:4210"},"canonical_url":"https://search.ndltd.org/etd/durham/oai:etheses.durham.ac.uk:4210","repository":{"repo_id":"durham","name":"Durham University","base_url":"http://etheses.dur.ac.uk/cgi/oai2"},"display":{"title":"Characterisation of luminescent and electrochemical sensors.","abstract":"This thesis is concerned with electrochemical and optical sensors based on potentiometric and luminescent transduction. A series of oxa-diisobutylamide derivatives based on cis-cis-l,3,5-cyclo-hexanetriol was compared in standard polyvinyl chloride based ion-selective electrodes as ionophores for the detection of selected IA/IIA cations. The tripodal framework incorporated either mono-, di- or tri- substituted diisobutyl amide pendant groups to give possible coordination numbers of 4, 5 and 6 respectively, assuming a 1:1 cationionophore stoichiometry. A Nemstian response towards the detection of Ca(^2+) was observed with the ISE incorporating the di-substituted diamide analogue. The selectivity of the ISE was assessed using the Fixed Interference Method and a Nemstian response was observed in the extracellular Ca(^2+) concentration range (1.16-1.32 mmol dm(^-3)) in the presence of a simulated extracellular background of interfering cations. The effect of pH on the response of the ISE was also investigated as was the enhancement of the lower detection limit by including a Ca(^2+) buffer in the inner filling electrolyte. Luminescent lanthanide complexes were assessed as chemical transducers for the purpose of optical sensing of pH or dissolved oxygen, following immobilisation in sol- gel thin films prepared in acidic media. pH-dependent intensity or ratiometric methods were defined for europium and terbium complexes of cyclen based frameworks (12-N(_4)). These systems incorporated phenanthridine derivatives or para substituted aryl sulfonamide moieties as the sensitising chromophores, typically with apparent pH sensing ranges of 5.5 to 8.0.Dissolved oxygen-dependent modulation of the metal emission and excited state lifetime of a short series of terbium complexes was assessed. These systems were based on cyclen with either tetra-amide or mono-amide triphosphinate pendent groups.","abstract_html":"This thesis is concerned with electrochemical and optical sensors based on potentiometric and luminescent transduction. A series of oxa-diisobutylamide derivatives based on cis-cis-l,3,5-cyclo-hexanetriol was compared in standard polyvinyl chloride based ion-selective electrodes as ionophores for the detection of selected IA/IIA cations. The tripodal framework incorporated either mono-, di- or tri- substituted diisobutyl amide pendant groups to give possible coordination numbers of 4, 5 and 6 respectively, assuming a 1:1 cationionophore stoichiometry. A Nemstian response towards the detection of Ca(^2+) was observed with the ISE incorporating the di-substituted diamide analogue. The selectivity of the ISE was assessed using the Fixed Interference Method and a Nemstian response was observed in the extracellular Ca(^2+) concentration range (1.16-1.32 mmol dm(^-3)) in the presence of a simulated extracellular background of interfering cations. The effect of pH on the response of the ISE was also investigated as was the enhancement of the lower detection limit by including a Ca(^2+) buffer in the inner filling electrolyte. Luminescent lanthanide complexes were assessed as chemical transducers for the purpose of optical sensing of pH or dissolved oxygen, following immobilisation in sol- gel thin films prepared in acidic media. pH-dependent intensity or ratiometric methods were defined for europium and terbium complexes of cyclen based frameworks (12-N(_4)). These systems incorporated phenanthridine derivatives or para substituted aryl sulfonamide moieties as the sensitising chromophores, typically with apparent pH sensing ranges of 5.5 to 8.0.Dissolved oxygen-dependent modulation of the metal emission and excited state lifetime of a short series of terbium complexes was assessed. These systems were based on cyclen with either tetra-amide or mono-amide triphosphinate pendent groups.","abstract_has_math":false,"creators":["Blair, Stephanie"],"institution":"Durham University","degree_name":"PhD","degree_level":"doctoral","degree_discipline":null,"degree_department":null,"school":null,"contributors":[],"advisors":[],"committee_chairs":[],"committee_members":[],"year":2001,"date_issued":"2001","date_published":"2001","updated_at":"2026-11-26T03:34:24Z","subjects":[],"languages":["eng"],"rights":[],"rights_urls":[],"identifier_entries":[{"key":"dc:identifier.grantnumber","label":"Dc Identifier Grantnumber","values":["UkUDh:CyT"],"render_values":[{"text":"UkUDh:CyT","href":null,"code":true}]}],"person_identifier_entries":[]},"links":{"outbound_url":"https://etheses.durham.ac.uk/id/eprint/4210/","outbound_label":"Repository record","outbound_source":"dc:identifier.uri","record_url":"https://etheses.durham.ac.uk/id/eprint/4210/","record_label":"Repository record","record_kind":"record","record_source":"dc:identifier.uri","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Adurham%3Aoai%3Aetheses.durham.ac.uk%3A4210","prefix":"oai_dc"},"source_record":{"url":"http://etheses.dur.ac.uk/cgi/oai2?verb=GetRecord&metadataPrefix=uketd_dc&identifier=oai%3Aetheses.durham.ac.uk%3A4210","prefix":"uketd_dc"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:creator","label":"Author","values":["Blair, Stephanie"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["2001"]},{"key":"dc:date.issued","label":"Date","values":["2001"]},{"key":"dc:publisher.department","label":"Dc Publisher Department","values":["Chemistry, Department of","Chemistry"]},{"key":"dc:publisher.institution","label":"Dc Publisher Institution","values":["Durham University"]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]},{"key":"dc:type.qualificationlevel","label":"Dc Type Qualificationlevel","values":["doctoral"]},{"key":"dc:type.qualificationname","label":"Dc Type Qualificationname","values":["PhD"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.dcterms_iso639_2","label":"Language (ISO 639-2)","values":["eng"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.grantnumber","label":"Dc Identifier Grantnumber","values":["UkUDh:CyT"]},{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://etheses.durham.ac.uk/id/eprint/4210/"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["This thesis is concerned with electrochemical and optical sensors based on potentiometric and luminescent transduction. A series of oxa-diisobutylamide derivatives based on cis-cis-l,3,5-cyclo-hexanetriol was compared in standard polyvinyl chloride based ion-selective electrodes as ionophores for the detection of selected IA/IIA cations. The tripodal framework incorporated either mono-, di- or tri- substituted diisobutyl amide pendant groups to give possible coordination numbers of 4, 5 and 6 respectively, assuming a 1:1 cationionophore stoichiometry. A Nemstian response towards the detection of Ca(^2+) was observed with the ISE incorporating the di-substituted diamide analogue. The selectivity of the ISE was assessed using the Fixed Interference Method and a Nemstian response was observed in the extracellular Ca(^2+) concentration range (1.16-1.32 mmol dm(^-3)) in the presence of a simulated extracellular background of interfering cations. The effect of pH on the response of the ISE was also investigated as was the enhancement of the lower detection limit by including a Ca(^2+) buffer in the inner filling electrolyte. Luminescent lanthanide complexes were assessed as chemical transducers for the purpose of optical sensing of pH or dissolved oxygen, following immobilisation in sol- gel thin films prepared in acidic media. pH-dependent intensity or ratiometric methods were defined for europium and terbium complexes of cyclen based frameworks (12-N(_4)). These systems incorporated phenanthridine derivatives or para substituted aryl sulfonamide moieties as the sensitising chromophores, typically with apparent pH sensing ranges of 5.5 to 8.0.Dissolved oxygen-dependent modulation of the metal emission and excited state lifetime of a short series of terbium complexes was assessed. These systems were based on cyclen with either tetra-amide or mono-amide triphosphinate pendent groups."]},{"key":"dc:format","label":"Dc Format","values":["text"]},{"key":"dcterms:accessrights","label":"Dcterms Accessrights","values":["public"]},{"key":"dc:title","label":"Title","values":["Characterisation of luminescent and electrochemical sensors."]}]}],"canonical_facts":{"dc:creator":["Blair, Stephanie"],"dc:date":["2001"],"dc:date.issued":["2001"],"dc:description.abstract":["This thesis is concerned with electrochemical and optical sensors based on potentiometric and luminescent transduction. A series of oxa-diisobutylamide derivatives based on cis-cis-l,3,5-cyclo-hexanetriol was compared in standard polyvinyl chloride based ion-selective electrodes as ionophores for the detection of selected IA/IIA cations. The tripodal framework incorporated either mono-, di- or tri- substituted diisobutyl amide pendant groups to give possible coordination numbers of 4, 5 and 6 respectively, assuming a 1:1 cationionophore stoichiometry. A Nemstian response towards the detection of Ca(^2+) was observed with the ISE incorporating the di-substituted diamide analogue. The selectivity of the ISE was assessed using the Fixed Interference Method and a Nemstian response was observed in the extracellular Ca(^2+) concentration range (1.16-1.32 mmol dm(^-3)) in the presence of a simulated extracellular background of interfering cations. The effect of pH on the response of the ISE was also investigated as was the enhancement of the lower detection limit by including a Ca(^2+) buffer in the inner filling electrolyte. Luminescent lanthanide complexes were assessed as chemical transducers for the purpose of optical sensing of pH or dissolved oxygen, following immobilisation in sol- gel thin films prepared in acidic media. pH-dependent intensity or ratiometric methods were defined for europium and terbium complexes of cyclen based frameworks (12-N(_4)). These systems incorporated phenanthridine derivatives or para substituted aryl sulfonamide moieties as the sensitising chromophores, typically with apparent pH sensing ranges of 5.5 to 8.0.Dissolved oxygen-dependent modulation of the metal emission and excited state lifetime of a short series of terbium complexes was assessed. These systems were based on cyclen with either tetra-amide or mono-amide triphosphinate pendent groups."],"dc:format":["text"],"dc:identifier.grantnumber":["UkUDh:CyT"],"dc:identifier.uri":["https://etheses.durham.ac.uk/id/eprint/4210/"],"dc:language.dcterms_iso639_2":["eng"],"dc:publisher.department":["Chemistry, Department of","Chemistry"],"dc:publisher.institution":["Durham University"],"dcterms:accessrights":["public"],"dc:title":["Characterisation of luminescent and electrochemical sensors."],"dc:type":["Thesis"],"dc:type.qualificationlevel":["doctoral"],"dc:type.qualificationname":["PhD"]},"updated_at":"2026-11-26T03:34:24Z"}