{"id":{"repo_id":"durham","oai_identifier":"oai:etheses.durham.ac.uk:8242"},"canonical_url":"https://search.ndltd.org/etd/durham/oai:etheses.durham.ac.uk:8242","repository":{"repo_id":"durham","name":"Durham University","base_url":"http://etheses.dur.ac.uk/cgi/oai2"},"display":{"title":"Some studies of multi-wire proportional chambers","abstract":"A study has been made of the displacement of sense wires in large multiwire proportional chambers, and methods are investigated to counteract this. A sense wire support which creates the minimum of dead-space while keeping the wires absolutely stationary is found to be a thin melinex strip stretched tightly across the wires. A brief review of some of the characteristics of transition radiation is then made; the application of the multiwire proportional chamber to detection of this radiation is described in the context of a pulse shape discrimination process developed for this purpose. Experiments with an X-ray and beta-particle source show that the technique should be capable of discriminating between an X-ray and a charged particle from an X-ray pulse superimposed upon a particle pulse. The discrimination process is used with 1.5 GeV electrons end pions traversing a 250 layer melinex stack and a block of plastic foam, the detector being an argon/methane filled proportional chamber. A maximum electron detection efficiency of M.B% is achieved, together with a maximum rejection ratio for non-radiating pions of 2.8.A further experiment with horizontal cosmic ray muons traversing a polyurethane foam radiator, and using a large 60cm x 30cm active area proportional chamber, yields a transition radiation photon flux of 0.023 per particle which is in good agreement with that calculated from the known horizontal muon spectrum and transition radiation theory.","abstract_html":"A study has been made of the displacement of sense wires in large multiwire proportional chambers, and methods are investigated to counteract this. A sense wire support which creates the minimum of dead-space while keeping the wires absolutely stationary is found to be a thin melinex strip stretched tightly across the wires. A brief review of some of the characteristics of transition radiation is then made; the application of the multiwire proportional chamber to detection of this radiation is described in the context of a pulse shape discrimination process developed for this purpose. Experiments with an X-ray and beta-particle source show that the technique should be capable of discriminating between an X-ray and a charged particle from an X-ray pulse superimposed upon a particle pulse. The discrimination process is used with 1.5 GeV electrons end pions traversing a 250 layer melinex stack and a block of plastic foam, the detector being an argon/methane filled proportional chamber. A maximum electron detection efficiency of M.B% is achieved, together with a maximum rejection ratio for non-radiating pions of 2.8.A further experiment with horizontal cosmic ray muons traversing a polyurethane foam radiator, and using a large 60cm x 30cm active area proportional chamber, yields a transition radiation photon flux of 0.023 per particle which is in good agreement with that calculated from the known horizontal muon spectrum and transition radiation theory.","abstract_has_math":false,"creators":["Smith, G. C."],"institution":"Durham University","degree_name":"PhD","degree_level":"doctoral","degree_discipline":null,"degree_department":null,"school":null,"contributors":[],"advisors":[],"committee_chairs":[],"committee_members":[],"year":1973,"date_issued":"1973","date_published":"1973","updated_at":"2026-11-26T03:56:42Z","subjects":[],"languages":["eng"],"rights":[],"rights_urls":[],"identifier_entries":[{"key":"dc:identifier.grantnumber","label":"Dc Identifier Grantnumber","values":["UkUDh:CyT"],"render_values":[{"text":"UkUDh:CyT","href":null,"code":true}]}],"person_identifier_entries":[]},"links":{"outbound_url":"https://etheses.durham.ac.uk/id/eprint/8242/","outbound_label":"Repository record","outbound_source":"dc:identifier.uri","record_url":"https://etheses.durham.ac.uk/id/eprint/8242/","record_label":"Repository record","record_kind":"record","record_source":"dc:identifier.uri","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Adurham%3Aoai%3Aetheses.durham.ac.uk%3A8242","prefix":"oai_dc"},"source_record":{"url":"http://etheses.dur.ac.uk/cgi/oai2?verb=GetRecord&metadataPrefix=uketd_dc&identifier=oai%3Aetheses.durham.ac.uk%3A8242","prefix":"uketd_dc"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:creator","label":"Author","values":["Smith, G. C."]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["1973"]},{"key":"dc:date.issued","label":"Date","values":["1973"]},{"key":"dc:publisher.department","label":"Dc Publisher Department","values":["Physics, Department of","Physics"]},{"key":"dc:publisher.institution","label":"Dc Publisher Institution","values":["Durham University"]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]},{"key":"dc:type.qualificationlevel","label":"Dc Type Qualificationlevel","values":["doctoral"]},{"key":"dc:type.qualificationname","label":"Dc Type Qualificationname","values":["PhD"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.dcterms_iso639_2","label":"Language (ISO 639-2)","values":["eng"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.grantnumber","label":"Dc Identifier Grantnumber","values":["UkUDh:CyT"]},{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://etheses.durham.ac.uk/id/eprint/8242/"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["A study has been made of the displacement of sense wires in large multiwire proportional chambers, and methods are investigated to counteract this. A sense wire support which creates the minimum of dead-space while keeping the wires absolutely stationary is found to be a thin melinex strip stretched tightly across the wires. A brief review of some of the characteristics of transition radiation is then made; the application of the multiwire proportional chamber to detection of this radiation is described in the context of a pulse shape discrimination process developed for this purpose. Experiments with an X-ray and beta-particle source show that the technique should be capable of discriminating between an X-ray and a charged particle from an X-ray pulse superimposed upon a particle pulse. The discrimination process is used with 1.5 GeV electrons end pions traversing a 250 layer melinex stack and a block of plastic foam, the detector being an argon/methane filled proportional chamber. A maximum electron detection efficiency of M.B% is achieved, together with a maximum rejection ratio for non-radiating pions of 2.8.A further experiment with horizontal cosmic ray muons traversing a polyurethane foam radiator, and using a large 60cm x 30cm active area proportional chamber, yields a transition radiation photon flux of 0.023 per particle which is in good agreement with that calculated from the known horizontal muon spectrum and transition radiation theory."]},{"key":"dc:format","label":"Dc Format","values":["text"]},{"key":"dcterms:accessrights","label":"Dcterms Accessrights","values":["public"]},{"key":"dc:title","label":"Title","values":["Some studies of multi-wire proportional chambers"]}]}],"canonical_facts":{"dc:creator":["Smith, G. C."],"dc:date":["1973"],"dc:date.issued":["1973"],"dc:description.abstract":["A study has been made of the displacement of sense wires in large multiwire proportional chambers, and methods are investigated to counteract this. A sense wire support which creates the minimum of dead-space while keeping the wires absolutely stationary is found to be a thin melinex strip stretched tightly across the wires. A brief review of some of the characteristics of transition radiation is then made; the application of the multiwire proportional chamber to detection of this radiation is described in the context of a pulse shape discrimination process developed for this purpose. Experiments with an X-ray and beta-particle source show that the technique should be capable of discriminating between an X-ray and a charged particle from an X-ray pulse superimposed upon a particle pulse. The discrimination process is used with 1.5 GeV electrons end pions traversing a 250 layer melinex stack and a block of plastic foam, the detector being an argon/methane filled proportional chamber. A maximum electron detection efficiency of M.B% is achieved, together with a maximum rejection ratio for non-radiating pions of 2.8.A further experiment with horizontal cosmic ray muons traversing a polyurethane foam radiator, and using a large 60cm x 30cm active area proportional chamber, yields a transition radiation photon flux of 0.023 per particle which is in good agreement with that calculated from the known horizontal muon spectrum and transition radiation theory."],"dc:format":["text"],"dc:identifier.grantnumber":["UkUDh:CyT"],"dc:identifier.uri":["https://etheses.durham.ac.uk/id/eprint/8242/"],"dc:language.dcterms_iso639_2":["eng"],"dc:publisher.department":["Physics, Department of","Physics"],"dc:publisher.institution":["Durham University"],"dcterms:accessrights":["public"],"dc:title":["Some studies of multi-wire proportional chambers"],"dc:type":["Thesis"],"dc:type.qualificationlevel":["doctoral"],"dc:type.qualificationname":["PhD"]},"updated_at":"2026-11-26T03:56:42Z"}