{"id":{"repo_id":"edinburgh","oai_identifier":"oai:era.ed.ac.uk:1842/20406"},"canonical_url":"https://search.ndltd.org/etd/edinburgh/oai:era.ed.ac.uk:1842/20406","repository":{"repo_id":"edinburgh","name":"University of Edinburgh","base_url":"https://era.ed.ac.uk/server/oai/request"},"display":{"title":"Critical review: evolution and impact of ultrasound guidance on brachial plexus anaesthesia.","abstract":"Brachial plexus block (BPB) techniques provide significant benefits including better pain control, faster discharge and reduced adverse effects compared to general anaesthesia. Prior to 2005 BPBs were performed using landmark, paraesthesia or electrical nerve stimulation (PNS) methods and were associated with reasonable success (70-80%) but were still associated with risk of failure and complications. Use of ultrasound (US) to guide local anaesthetic injection was first reported in 1989 but until 2004 remained unexplored. From 2004 we aimed to explore the feasibility, success and safety of ultrasound-guided brachial plexus block (USBPB) compared to techniques guided by anatomical landmarks or peripheral nerve stimulation. We hypothesized that USBPB would be feasible, have greater success and safety compared to standard methods. In 2004 we identified the possibility of using US to place infraclavicular block (ICB) and identified a pattern of local anaesthetic spread that predicated successful block. A subsequent randomized trial found improved success of US compared to existing methods. We examined success of US-guided axillary brachial plexus block (ABPB) and found that performance time and success were improved. In a large retrospective review of ABPB techniques we identified that US techniques were faster to perform, had a higher success and were safer compared to standard methods. We also assessed existing nerve localization methods in an observational study and found that both have poor sensitivity and specificity possibly explaining some of the limitations of these techniques. A bench study examining local anaesthetic injection using ultrasound found that both novices and experts could accurately determine local anaesthetic spread. In practice this is a useful marker for safe injection and could explain findings of increased safety with ultrasound methods. we systematically reviewed the literature for studies examining USBPB and this demonstrated that US improved block success and performance time. Subsequent pilot work indicated that US, in addition to improves block success and performance time. Subsequent pilot work indicated that US, in addition to improving quality, could also reduce volume of local anaesthetic required for successful block and we hypothesized that for certain techniques such as interscalene block this may improve safely. we compared US-guided interscalene block (ISB) using traditional volumes (20ml) and compared with a low volume (5ml) of ropivacaine 0.5%. Results demonstrated no difference in efficacy or duration but significant reduction in respiratory (and other) complications with lower volumes. We then compared US-guide ISB to PNS using and Up and Down Sequential Allocation design to estimate the minimum effective anaesthetic volume (MEAV50) for ropivavaine 0.5% for major shoulder surgery. Our findings indicated that volumes of local anaesthetic could be dramatically reduced with US (0.9 vs 5.4ml) whilst still providing effective pain relief. In the last ten years the cases and studies described have demonstrated that US improves BPB success and safety. For ISB US reduces volumes of local anaesthetic required for success whilst also reducing respiratory and other complications.","abstract_html":"Brachial plexus block (BPB) techniques provide significant benefits including better pain control, faster discharge and reduced adverse effects compared to general anaesthesia. Prior to 2005 BPBs were performed using landmark, paraesthesia or electrical nerve stimulation (PNS) methods and were associated with reasonable success (70-80%) but were still associated with risk of failure and complications. Use of ultrasound (US) to guide local anaesthetic injection was first reported in 1989 but until 2004 remained unexplored. From 2004 we aimed to explore the feasibility, success and safety of ultrasound-guided brachial plexus block (USBPB) compared to techniques guided by anatomical landmarks or peripheral nerve stimulation. We hypothesized that USBPB would be feasible, have greater success and safety compared to standard methods. In 2004 we identified the possibility of using US to place infraclavicular block (ICB) and identified a pattern of local anaesthetic spread that predicated successful block. A subsequent randomized trial found improved success of US compared to existing methods. We examined success of US-guided axillary brachial plexus block (ABPB) and found that performance time and success were improved. In a large retrospective review of ABPB techniques we identified that US techniques were faster to perform, had a higher success and were safer compared to standard methods. We also assessed existing nerve localization methods in an observational study and found that both have poor sensitivity and specificity possibly explaining some of the limitations of these techniques. A bench study examining local anaesthetic injection using ultrasound found that both novices and experts could accurately determine local anaesthetic spread. In practice this is a useful marker for safe injection and could explain findings of increased safety with ultrasound methods. we systematically reviewed the literature for studies examining USBPB and this demonstrated that US improved block success and performance time. Subsequent pilot work indicated that US, in addition to improves block success and performance time. Subsequent pilot work indicated that US, in addition to improving quality, could also reduce volume of local anaesthetic required for successful block and we hypothesized that for certain techniques such as interscalene block this may improve safely. we compared US-guided interscalene block (ISB) using traditional volumes (20ml) and compared with a low volume (5ml) of ropivacaine 0.5%. Results demonstrated no difference in efficacy or duration but significant reduction in respiratory (and other) complications with lower volumes. We then compared US-guide ISB to PNS using and Up and Down Sequential Allocation design to estimate the minimum effective anaesthetic volume (MEAV50) for ropivavaine 0.5% for major shoulder surgery. Our findings indicated that volumes of local anaesthetic could be dramatically reduced with US (0.9 vs 5.4ml) whilst still providing effective pain relief. In the last ten years the cases and studies described have demonstrated that US improves BPB success and safety. For ISB US reduces volumes of local anaesthetic required for success whilst also reducing respiratory and other complications.","abstract_has_math":false,"creators":["McCartney, Colin John Lindsay"],"institution":"The University of Edinburgh","degree_name":null,"degree_level":null,"degree_discipline":null,"degree_department":null,"school":null,"contributors":[],"advisors":["Colvin, Lesley"],"committee_chairs":[],"committee_members":[],"year":2015,"date_issued":"2015-11-27","date_published":"2015-11-27","updated_at":"2026-11-19T03:34:36Z","subjects":["regional anaesthesia","ultrasound"],"languages":["en"],"rights":["Attribution-NonCommercial-ShareAlike 4.0 International"],"rights_urls":["http://creativecommons.org/licenses/by-nc-sa/4.0/"],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"http://hdl.handle.net/1842/20406","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"http://hdl.handle.net/1842/20406","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://era.ed.ac.uk/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Aera.ed.ac.uk%3A1842%2F20406","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Colvin, Lesley"]},{"key":"dc:contributor.sponsor","label":"Sponsor","values":["other"]},{"key":"dc:creator","label":"Author","values":["McCartney, Colin John Lindsay"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2017-02-22T15:42:34Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2017-02-22T15:42:34Z"]},{"key":"dc:date.issued","label":"Date","values":["2015-11-27"]},{"key":"dc:publisher","label":"Institution","values":["The University of Edinburgh"]},{"key":"dc:relation.hasversion","label":"Dc Relation Hasversion","values":["McCartney CJ, Brull R, Chan VW, Katz J, Abbes S, Graham B, Nova H, Rawson R, Anastakis DJ, von Schroeder H. Early but no long-term benefit of regional compared with general anesthesia for ambulatory hand surgery. Anesthesiology. 2004; 101: 461-7.","Brull R, McCartney CJ, Chan VW. A novel approach to infraclavicular brachial plexus block: the ultrasound experience. Anesth Analg 2004; 99: 950.","Porter JM, McCaratney CJ, Chan VW. Needle placement and injection posterior to the anxillary artery may predict successful infraclavicular brachial plexus block: a report of three cases. Can J Anaesth 2005; 52: 69-73.","Assmann N, McCartney CJm Tumber PS, Chan VW. Ultrasound guidance for brachial plexus localization and catheter insertion after complexe forearm amputation. Reg Anesth PAin Med 2007; 32:93.","van Geffen GJ, McCartney CJ, Gielen M, Chan VW. Ultrasound as the only nerve localization technique for peripheral nerve block. J Clin Anesth 2007; 19: 381-5.","Brull R, Lupu M, Perlas A, Chan VW, McCartney CJ. Compared with dual nerve stumulation, ultrasound guidance shortens the time for infraclavicular block performance. Can J Anaesth 2009; 56: 812-8.","chan VW, Perlas A, McCartney CJ, Brull R, Xu D, Abbas S. Ultrasound guidance improves success rate of axillary brachial plexus block. Can J Anaesth. 2007; 54: 176-82.","Lo N, Brull R, Perlas A, Chan VW, McCartney CJ, Sacco R, El-Beheiry H. Evolution of ultrasound guided axillary brachial plexus blockade: retrospective analysis of 662 blocks. Can J Anaesth 2008; 55: 408-13.","Perlas A, Niazi A, McCartney C, Chan V, Xu D, Abbas S. The sensitivity of motor response to nerve stumulation and paresthesia for nerve localization as evaluation by ultrasound. Reg Anesth Pain Med. 2006; 31: 445-50.","McCartney CJ, Lin L, Shastri U. Evidence basis for the use of ultrasound for upper-extremity blocks. Reg Anesth Pain Med 2010; 35: S10-5.","McCartney CJ, Patel S. Local anesthetic volume for peripheral nerve blocks: how low can (or should) we go? Reg Anesth Pain Med; 37: 239-41.","McCartney CJ, Dickinson V, Dubrowski A, Riazi S, McHardy P, Awad IT. Ultrasound provides a reliable test of local anesthetic spread. Reg Anesth Pain Med 2010; 35: 361-3.","Riazi S, Carmichael N, Awad I, Holtby RM, McCartney CJ. Effect of local anaesthetic volume (20 vs 5 ml) on the efficacy and respiratory consequences of ultrasound-guided interscalene brachial plexus block. Br J Anaesth 2008; 101: 549-56.","McNaught A, Shastri U, Caramichael N, Awad IT, Columb M, Cheung J, Holtby RM, McCartney CJ. Ultrasound reduces the minimum effective local anaesthetic volume compared with peripheral nerve stumulation for interscalene block. Br J Anaesth 2001; 106: 124-30."]},{"key":"dc:type","label":"Dc Type","values":["Thesis or Dissertation"]},{"key":"dc:type.qualificationlevel","label":"Dc Type Qualificationlevel","values":["Doctoral"]},{"key":"dc:type.qualificationname","label":"Dc Type Qualificationname","values":["PhD(P) Doctor of Philosophy by Research Publications"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["regional anaesthesia","ultrasound"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["en"]},{"key":"dc:rights","label":"Dc Rights","values":["Attribution-NonCommercial-ShareAlike 4.0 International"]},{"key":"dc:rights.uri","label":"Rights URI","values":["http://creativecommons.org/licenses/by-nc-sa/4.0/"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["http://hdl.handle.net/1842/20406"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["Brachial plexus block (BPB) techniques provide significant benefits including better pain control, faster discharge and reduced adverse effects compared to general anaesthesia. Prior to 2005 BPBs were performed using landmark, paraesthesia or electrical nerve stimulation (PNS) methods and were associated with reasonable success (70-80%) but were still associated with risk of failure and complications. Use of ultrasound (US) to guide local anaesthetic injection was first reported in 1989 but until 2004 remained unexplored. From 2004 we aimed to explore the feasibility, success and safety of ultrasound-guided brachial plexus block (USBPB) compared to techniques guided by anatomical landmarks or peripheral nerve stimulation. We hypothesized that USBPB would be feasible, have greater success and safety compared to standard methods. In 2004 we identified the possibility of using US to place infraclavicular block (ICB) and identified a pattern of local anaesthetic spread that predicated successful block. A subsequent randomized trial found improved success of US compared to existing methods. We examined success of US-guided axillary brachial plexus block (ABPB) and found that performance time and success were improved. In a large retrospective review of ABPB techniques we identified that US techniques were faster to perform, had a higher success and were safer compared to standard methods. We also assessed existing nerve localization methods in an observational study and found that both have poor sensitivity and specificity possibly explaining some of the limitations of these techniques. A bench study examining local anaesthetic injection using ultrasound found that both novices and experts could accurately determine local anaesthetic spread. In practice this is a useful marker for safe injection and could explain findings of increased safety with ultrasound methods. we systematically reviewed the literature for studies examining USBPB and this demonstrated that US improved block success and performance time. Subsequent pilot work indicated that US, in addition to improves block success and performance time. Subsequent pilot work indicated that US, in addition to improving quality, could also reduce volume of local anaesthetic required for successful block and we hypothesized that for certain techniques such as interscalene block this may improve safely. we compared US-guided interscalene block (ISB) using traditional volumes (20ml) and compared with a low volume (5ml) of ropivacaine 0.5%. Results demonstrated no difference in efficacy or duration but significant reduction in respiratory (and other) complications with lower volumes. We then compared US-guide ISB to PNS using and Up and Down Sequential Allocation design to estimate the minimum effective anaesthetic volume (MEAV50) for ropivavaine 0.5% for major shoulder surgery. Our findings indicated that volumes of local anaesthetic could be dramatically reduced with US (0.9 vs 5.4ml) whilst still providing effective pain relief. In the last ten years the cases and studies described have demonstrated that US improves BPB success and safety. For ISB US reduces volumes of local anaesthetic required for success whilst also reducing respiratory and other complications."]},{"key":"dc:title","label":"Title","values":["Critical review: evolution and impact of ultrasound guidance on brachial plexus anaesthesia."]},{"key":"others:access_status","label":"Others Access Status","values":["open.access"]}]}],"canonical_facts":{"dc:contributor.advisor":["Colvin, Lesley"],"dc:contributor.sponsor":["other"],"dc:creator":["McCartney, Colin John Lindsay"],"dc:date.accessioned":["2017-02-22T15:42:34Z"],"dc:date.available":["2017-02-22T15:42:34Z"],"dc:date.issued":["2015-11-27"],"dc:description.abstract":["Brachial plexus block (BPB) techniques provide significant benefits including better pain control, faster discharge and reduced adverse effects compared to general anaesthesia. Prior to 2005 BPBs were performed using landmark, paraesthesia or electrical nerve stimulation (PNS) methods and were associated with reasonable success (70-80%) but were still associated with risk of failure and complications. Use of ultrasound (US) to guide local anaesthetic injection was first reported in 1989 but until 2004 remained unexplored. From 2004 we aimed to explore the feasibility, success and safety of ultrasound-guided brachial plexus block (USBPB) compared to techniques guided by anatomical landmarks or peripheral nerve stimulation. We hypothesized that USBPB would be feasible, have greater success and safety compared to standard methods. In 2004 we identified the possibility of using US to place infraclavicular block (ICB) and identified a pattern of local anaesthetic spread that predicated successful block. A subsequent randomized trial found improved success of US compared to existing methods. We examined success of US-guided axillary brachial plexus block (ABPB) and found that performance time and success were improved. In a large retrospective review of ABPB techniques we identified that US techniques were faster to perform, had a higher success and were safer compared to standard methods. We also assessed existing nerve localization methods in an observational study and found that both have poor sensitivity and specificity possibly explaining some of the limitations of these techniques. A bench study examining local anaesthetic injection using ultrasound found that both novices and experts could accurately determine local anaesthetic spread. In practice this is a useful marker for safe injection and could explain findings of increased safety with ultrasound methods. we systematically reviewed the literature for studies examining USBPB and this demonstrated that US improved block success and performance time. Subsequent pilot work indicated that US, in addition to improves block success and performance time. Subsequent pilot work indicated that US, in addition to improving quality, could also reduce volume of local anaesthetic required for successful block and we hypothesized that for certain techniques such as interscalene block this may improve safely. we compared US-guided interscalene block (ISB) using traditional volumes (20ml) and compared with a low volume (5ml) of ropivacaine 0.5%. Results demonstrated no difference in efficacy or duration but significant reduction in respiratory (and other) complications with lower volumes. We then compared US-guide ISB to PNS using and Up and Down Sequential Allocation design to estimate the minimum effective anaesthetic volume (MEAV50) for ropivavaine 0.5% for major shoulder surgery. Our findings indicated that volumes of local anaesthetic could be dramatically reduced with US (0.9 vs 5.4ml) whilst still providing effective pain relief. In the last ten years the cases and studies described have demonstrated that US improves BPB success and safety. For ISB US reduces volumes of local anaesthetic required for success whilst also reducing respiratory and other complications."],"dc:identifier.uri":["http://hdl.handle.net/1842/20406"],"dc:language.iso":["en"],"dc:publisher":["The University of Edinburgh"],"dc:relation.hasversion":["McCartney CJ, Brull R, Chan VW, Katz J, Abbes S, Graham B, Nova H, Rawson R, Anastakis DJ, von Schroeder H. Early but no long-term benefit of regional compared with general anesthesia for ambulatory hand surgery. Anesthesiology. 2004; 101: 461-7.","Brull R, McCartney CJ, Chan VW. A novel approach to infraclavicular brachial plexus block: the ultrasound experience. Anesth Analg 2004; 99: 950.","Porter JM, McCaratney CJ, Chan VW. Needle placement and injection posterior to the anxillary artery may predict successful infraclavicular brachial plexus block: a report of three cases. Can J Anaesth 2005; 52: 69-73.","Assmann N, McCartney CJm Tumber PS, Chan VW. Ultrasound guidance for brachial plexus localization and catheter insertion after complexe forearm amputation. Reg Anesth PAin Med 2007; 32:93.","van Geffen GJ, McCartney CJ, Gielen M, Chan VW. Ultrasound as the only nerve localization technique for peripheral nerve block. J Clin Anesth 2007; 19: 381-5.","Brull R, Lupu M, Perlas A, Chan VW, McCartney CJ. Compared with dual nerve stumulation, ultrasound guidance shortens the time for infraclavicular block performance. Can J Anaesth 2009; 56: 812-8.","chan VW, Perlas A, McCartney CJ, Brull R, Xu D, Abbas S. Ultrasound guidance improves success rate of axillary brachial plexus block. Can J Anaesth. 2007; 54: 176-82.","Lo N, Brull R, Perlas A, Chan VW, McCartney CJ, Sacco R, El-Beheiry H. Evolution of ultrasound guided axillary brachial plexus blockade: retrospective analysis of 662 blocks. Can J Anaesth 2008; 55: 408-13.","Perlas A, Niazi A, McCartney C, Chan V, Xu D, Abbas S. The sensitivity of motor response to nerve stumulation and paresthesia for nerve localization as evaluation by ultrasound. Reg Anesth Pain Med. 2006; 31: 445-50.","McCartney CJ, Lin L, Shastri U. Evidence basis for the use of ultrasound for upper-extremity blocks. Reg Anesth Pain Med 2010; 35: S10-5.","McCartney CJ, Patel S. Local anesthetic volume for peripheral nerve blocks: how low can (or should) we go? Reg Anesth Pain Med; 37: 239-41.","McCartney CJ, Dickinson V, Dubrowski A, Riazi S, McHardy P, Awad IT. Ultrasound provides a reliable test of local anesthetic spread. Reg Anesth Pain Med 2010; 35: 361-3.","Riazi S, Carmichael N, Awad I, Holtby RM, McCartney CJ. Effect of local anaesthetic volume (20 vs 5 ml) on the efficacy and respiratory consequences of ultrasound-guided interscalene brachial plexus block. Br J Anaesth 2008; 101: 549-56.","McNaught A, Shastri U, Caramichael N, Awad IT, Columb M, Cheung J, Holtby RM, McCartney CJ. Ultrasound reduces the minimum effective local anaesthetic volume compared with peripheral nerve stumulation for interscalene block. Br J Anaesth 2001; 106: 124-30."],"dc:rights":["Attribution-NonCommercial-ShareAlike 4.0 International"],"dc:rights.uri":["http://creativecommons.org/licenses/by-nc-sa/4.0/"],"dc:subject":["regional anaesthesia","ultrasound"],"dc:title":["Critical review: evolution and impact of ultrasound guidance on brachial plexus anaesthesia."],"dc:type":["Thesis or Dissertation"],"dc:type.qualificationlevel":["Doctoral"],"dc:type.qualificationname":["PhD(P) Doctor of Philosophy by Research Publications"],"others:access_status":["open.access"]},"updated_at":"2026-11-19T03:34:36Z"}