{"id":{"repo_id":"edinburgh","oai_identifier":"oai:era.ed.ac.uk:1842/26559"},"canonical_url":"https://search.ndltd.org/etd/edinburgh/oai:era.ed.ac.uk:1842/26559","repository":{"repo_id":"edinburgh","name":"University of Edinburgh","base_url":"https://era.ed.ac.uk/server/oai/request"},"display":{"title":"Immunoliposomes in haematology","abstract":"The aim of this -thesis was to use antibody-directed liposomes to enhance the targeting of 1. fluorescent compounds for the detection of cell surface antigens and 2. cytotoxic compounds for delivery to specific cell populations. This involved the selection and production of a suitable species of 1ipoaome-protein conjugate from among those described in the literature. The choice was a small unilamellar liposome conjugated either to antibody or protein A via a covalent linkage mediated by the heterobifunctional reagent SPDP.","abstract_html":"The aim of this -thesis was to use antibody-directed liposomes to enhance the targeting of 1. fluorescent compounds for the detection of cell surface antigens and 2. cytotoxic compounds for delivery to specific cell populations. This involved the selection and production of a suitable species of 1ipoaome-protein conjugate from among those described in the literature. The choice was a small unilamellar liposome conjugated either to antibody or protein A via a covalent linkage mediated by the heterobifunctional reagent SPDP.","abstract_has_math":false,"creators":["Gray, Atherton."],"institution":"The University of Edinburgh","degree_name":null,"degree_level":null,"degree_discipline":null,"degree_department":null,"school":null,"contributors":[],"advisors":[],"committee_chairs":[],"committee_members":[],"year":1992,"date_issued":"1992","date_published":"1992","updated_at":"2026-11-18T19:26:33Z","subjects":[],"languages":[],"rights":[],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"https://hdl.handle.net/1842/26559","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"https://hdl.handle.net/1842/26559","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Aedinburgh%3Aoai%3Aera.ed.ac.uk%3A1842%2F26559","prefix":"oai_dc"},"source_record":{"url":"https://era.ed.ac.uk/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Aera.ed.ac.uk%3A1842%2F26559","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:creator","label":"Author","values":["Gray, Atherton."]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2018-01-31T11:20:57Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2018-01-31T11:20:57Z"]},{"key":"dc:date.issued","label":"Date","values":["1992"]},{"key":"dc:publisher","label":"Institution","values":["The University of Edinburgh"]},{"key":"dc:relation.ispartof","label":"Dc Relation Ispartof","values":["Annexe Thesis Digitisation Project 2017 Block 15"]},{"key":"dc:type","label":"Dc Type","values":["Thesis or Dissertation"]},{"key":"dc:type.qualificationlevel","label":"Dc Type Qualificationlevel","values":["Doctoral"]},{"key":"dc:type.qualificationname","label":"Dc Type Qualificationname","values":["MD Doctor of Medicine"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["http://hdl.handle.net/1842/26559"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["The aim of this -thesis was to use antibody-directed liposomes to enhance the targeting of 1. fluorescent compounds for the detection of cell surface antigens and 2. cytotoxic compounds for delivery to specific cell populations. This involved the selection and production of a suitable species of 1ipoaome-protein conjugate from among those described in the literature. The choice was a small unilamellar liposome conjugated either to antibody or protein A via a covalent linkage mediated by the heterobifunctional reagent SPDP.","Anti-immunoglobulin antibody was a more universal ligand than either specific antibody or protein A. The conjugate was made fluorescent by the encapsulation of carboxyfluorescein <CF) in the liposome and the maximally fluorescent concentration was determined at 20 mM CF. The probe was stable on storage over many months and had low non-specific staining characteristics. Applied to lymphocytes it gave a signal enhancement an order of magnitude greater than the conventional fluorescentantibody method as measured by flow cytometry. This permitted the demonstration of the interleukin-2 receptor on resting polyclonal T-lymphocytes hitherto undetectable by conventional fluorescence. The threshold of detectabi1ity was set at less than lOOO antigen copies per cell.","A range of clinically significant antigens on red cells were visually detectable using the fluorescent liposomes. These included heterozygoualy expressed Kell, Duffy and Kidd antigens which had not previously been demonstrated by fluorescence due to the fluorescence quenching effect of haemoglobin. The technique was an order of magnitude more sensitive than the fluorescent antibody method and also proved more sensitive than the indirect antiglobulin teat in the detection of heterozygous Rh(D) and Fya cells. The probe was used to predict foeto-maternal blood group antagonism in a pregnancy at risk for haemolytic disease of the newborn using cells obtained from a chorionic villous sample in the first trimester.","Liposomes containing methotrexate were targeted to T cells among peripheral blood lymphocytes using anti-CD3 antibody. Evidence demonstrating the intracellular delivery of methotrexate is given. The cytotoxic effect was dose-dependent with respect to the concentration of targeting antibody and liposome concentration. There was 80* and 90* growth inhibition after 24 and 48 hours respectively. The kinetics of the response made the technique impractical for the purposes of T cell depletion or purging of harvested bone marrow. However the specificity of the toxicity to targeted cells validated the approach for use with more rapidly cytotoxic agents."]},{"key":"dc:title","label":"Title","values":["Immunoliposomes in haematology"]},{"key":"others:access_status","label":"Others Access Status","values":["open.access"]}]}],"canonical_facts":{"dc:creator":["Gray, Atherton."],"dc:date.accessioned":["2018-01-31T11:20:57Z"],"dc:date.available":["2018-01-31T11:20:57Z"],"dc:date.issued":["1992"],"dc:description.abstract":["The aim of this -thesis was to use antibody-directed liposomes to enhance the targeting of 1. fluorescent compounds for the detection of cell surface antigens and 2. cytotoxic compounds for delivery to specific cell populations. This involved the selection and production of a suitable species of 1ipoaome-protein conjugate from among those described in the literature. The choice was a small unilamellar liposome conjugated either to antibody or protein A via a covalent linkage mediated by the heterobifunctional reagent SPDP.","Anti-immunoglobulin antibody was a more universal ligand than either specific antibody or protein A. The conjugate was made fluorescent by the encapsulation of carboxyfluorescein <CF) in the liposome and the maximally fluorescent concentration was determined at 20 mM CF. The probe was stable on storage over many months and had low non-specific staining characteristics. Applied to lymphocytes it gave a signal enhancement an order of magnitude greater than the conventional fluorescentantibody method as measured by flow cytometry. This permitted the demonstration of the interleukin-2 receptor on resting polyclonal T-lymphocytes hitherto undetectable by conventional fluorescence. The threshold of detectabi1ity was set at less than lOOO antigen copies per cell.","A range of clinically significant antigens on red cells were visually detectable using the fluorescent liposomes. These included heterozygoualy expressed Kell, Duffy and Kidd antigens which had not previously been demonstrated by fluorescence due to the fluorescence quenching effect of haemoglobin. The technique was an order of magnitude more sensitive than the fluorescent antibody method and also proved more sensitive than the indirect antiglobulin teat in the detection of heterozygous Rh(D) and Fya cells. The probe was used to predict foeto-maternal blood group antagonism in a pregnancy at risk for haemolytic disease of the newborn using cells obtained from a chorionic villous sample in the first trimester.","Liposomes containing methotrexate were targeted to T cells among peripheral blood lymphocytes using anti-CD3 antibody. Evidence demonstrating the intracellular delivery of methotrexate is given. The cytotoxic effect was dose-dependent with respect to the concentration of targeting antibody and liposome concentration. There was 80* and 90* growth inhibition after 24 and 48 hours respectively. The kinetics of the response made the technique impractical for the purposes of T cell depletion or purging of harvested bone marrow. However the specificity of the toxicity to targeted cells validated the approach for use with more rapidly cytotoxic agents."],"dc:identifier.uri":["http://hdl.handle.net/1842/26559"],"dc:publisher":["The University of Edinburgh"],"dc:relation.ispartof":["Annexe Thesis Digitisation Project 2017 Block 15"],"dc:title":["Immunoliposomes in haematology"],"dc:type":["Thesis or Dissertation"],"dc:type.qualificationlevel":["Doctoral"],"dc:type.qualificationname":["MD Doctor of Medicine"],"others:access_status":["open.access"]},"updated_at":"2026-11-18T19:26:33Z"}