{"id":{"repo_id":"edinburgh","oai_identifier":"oai:era.ed.ac.uk:1842/28583"},"canonical_url":"https://search.ndltd.org/etd/edinburgh/oai:era.ed.ac.uk:1842/28583","repository":{"repo_id":"edinburgh","name":"University of Edinburgh","base_url":"https://era.ed.ac.uk/server/oai/request"},"display":{"title":"Ultrasonic blood flow detection: Doppler techniques for obstetrics","abstract":"Ultrasonic Doppler techniques have been developed for the detection of uterine blood flow. The work was undertaken to provide a noninvasive method for the study of foetal haemodynamics.","abstract_html":"Ultrasonic Doppler techniques have been developed for the detection of uterine blood flow. The work was undertaken to provide a noninvasive method for the study of foetal haemodynamics.","abstract_has_math":false,"creators":["McHugh, Ronald"],"institution":"The University of Edinburgh","degree_name":null,"degree_level":null,"degree_discipline":null,"degree_department":null,"school":null,"contributors":[],"advisors":[],"committee_chairs":[],"committee_members":[],"year":1980,"date_issued":"1980","date_published":"1980","updated_at":"2026-11-18T19:25:08Z","subjects":[],"languages":[],"rights":[],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"http://hdl.handle.net/1842/28583","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"http://hdl.handle.net/1842/28583","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://era.ed.ac.uk/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Aera.ed.ac.uk%3A1842%2F28583","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:creator","label":"Author","values":["McHugh, Ronald"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2018-01-31T11:48:11Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2018-01-31T11:48:11Z"]},{"key":"dc:date.issued","label":"Date","values":["1980"]},{"key":"dc:publisher","label":"Institution","values":["The University of Edinburgh"]},{"key":"dc:relation.ispartof","label":"Dc Relation Ispartof","values":["Annexe Thesis Digitisation Project 2017 Block 16"]},{"key":"dc:relation.isreferencedby","label":"Dc Relation Isreferencedby","values":["Already catalogued"]},{"key":"dc:type","label":"Dc Type","values":["Thesis or Dissertation"]},{"key":"dc:type.qualificationlevel","label":"Dc Type Qualificationlevel","values":["Doctoral"]},{"key":"dc:type.qualificationname","label":"Dc Type Qualificationname","values":["MPhil Master of Philosophy"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["http://hdl.handle.net/1842/28583"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["Ultrasonic Doppler techniques have been developed for the detection of uterine blood flow. The work was undertaken to provide a noninvasive method for the study of foetal haemodynamics.","The operation of the continuous wave and the pulsed wave Doppler instruments and the factors which influence their performance are discussed. The different types of Doppler signal extraction techniques which can be used with the pulsed wave Doppler are described. A design for a 2.5 MHz pulsed wave Doppler instrument is presented. The results of in vivo and in vitro trials with this instrument are presented.","A blood flow instrument specially designed for examining blood flow in the pregnant uterus is described. It consists of a real time ultrasonic scanner of rotating transducer design used in conjunction with the above types of Doppler instrument. In vivo evaluation of this equipment is presented.","A novel type of continuous wave Doppler instrument, the intersecting zone Doppler is described. This device overcomes the problem of lack of localisation normally associated with the continuous wave device.","A composite blood flow system incorporating all three Doppler techniques is described. Blood flow spectrograms from various sites within the pregnant uterus are presented."]},{"key":"dc:title","label":"Title","values":["Ultrasonic blood flow detection: Doppler techniques for obstetrics"]},{"key":"others:access_status","label":"Others Access Status","values":["open.access"]}]}],"canonical_facts":{"dc:creator":["McHugh, Ronald"],"dc:date.accessioned":["2018-01-31T11:48:11Z"],"dc:date.available":["2018-01-31T11:48:11Z"],"dc:date.issued":["1980"],"dc:description.abstract":["Ultrasonic Doppler techniques have been developed for the detection of uterine blood flow. The work was undertaken to provide a noninvasive method for the study of foetal haemodynamics.","The operation of the continuous wave and the pulsed wave Doppler instruments and the factors which influence their performance are discussed. The different types of Doppler signal extraction techniques which can be used with the pulsed wave Doppler are described. A design for a 2.5 MHz pulsed wave Doppler instrument is presented. The results of in vivo and in vitro trials with this instrument are presented.","A blood flow instrument specially designed for examining blood flow in the pregnant uterus is described. It consists of a real time ultrasonic scanner of rotating transducer design used in conjunction with the above types of Doppler instrument. In vivo evaluation of this equipment is presented.","A novel type of continuous wave Doppler instrument, the intersecting zone Doppler is described. This device overcomes the problem of lack of localisation normally associated with the continuous wave device.","A composite blood flow system incorporating all three Doppler techniques is described. Blood flow spectrograms from various sites within the pregnant uterus are presented."],"dc:identifier.uri":["http://hdl.handle.net/1842/28583"],"dc:publisher":["The University of Edinburgh"],"dc:relation.ispartof":["Annexe Thesis Digitisation Project 2017 Block 16"],"dc:relation.isreferencedby":["Already catalogued"],"dc:title":["Ultrasonic blood flow detection: Doppler techniques for obstetrics"],"dc:type":["Thesis or Dissertation"],"dc:type.qualificationlevel":["Doctoral"],"dc:type.qualificationname":["MPhil Master of Philosophy"],"others:access_status":["open.access"]},"updated_at":"2026-11-18T19:25:08Z"}