{"id":{"repo_id":"edinburgh","oai_identifier":"oai:era.ed.ac.uk:1842/28877"},"canonical_url":"https://search.ndltd.org/etd/edinburgh/oai:era.ed.ac.uk:1842/28877","repository":{"repo_id":"edinburgh","name":"University of Edinburgh","base_url":"https://era.ed.ac.uk/server/oai/request"},"display":{"title":"Multicentre evaluation of MRI variability in the quantification of infarct size in experimental focal cerebral ischaemia","abstract":"Ischaemic stroke is a leading cause of death and disability in the developed world. Despite that considerable advances in experimental research enabled understanding of the pathophysiology of the disease and identified hundreds of potential neuroprotective drugs for treatment, no such drug has shown efficacy in humans. The failure in the translation from bench to bedside has been partially attributed to the poor quality and rigour of animal studies. Recently, it has been suggested that multicentre animal studies imitating the design of randomised clinical trials could improve the translation of experimental research. Magnetic resonance imaging (MRI) could be pivotal in such studies due to its non-invasive nature and its high sensitivity to ischaemic lesions, but its accuracy and concordance across centres has not yet been evaluated. This thesis focussed on the use of MRI for the assessment of late infarct size, the primary outcome used in stroke models. Initially, a systematic review revealed that a plethora of imaging protocols and data analysis methods are used for this purpose. Using meta-analysis techniques, it was determined that T2-weighted imaging (T2WI) was best correlated with gold standard histology for the measurement of infarctbased treatment effects. Then, geometric accuracy in six different preclinical MRI scanners was assessed using structural phantoms and automated data analysis tools developed in-house. It was found that geometric accuracy varies between scanners, particularly when centre-specific T2WI protocols are used instead of a standardised protocol, though longitudinal stability over six months is high. Finally, a simulation study suggested that the measured geometric errors and the different protocols are sufficient to render infarct volumes and related group comparisons across centres incomparable. The variability increases when both factors are taken into account and when infarct volume is expressed as a relative estimate. Data in this study were analysed using a custom-made semi-automated tool that was faster and more reliable in repeated analyses than manual analysis. Findings of this thesis support the implementation of standardised methods for the assessment and optimisation of geometric accuracy in MRI scanners, as well as image acquisition and analysis of in vivo data for the measurement of infarct size in multicentre animal studies. Tools and techniques developed as part of the thesis show great promise in the analysis of phantom and in vivo data and could be a step towards this endeavour.","abstract_html":"Ischaemic stroke is a leading cause of death and disability in the developed world. Despite that considerable advances in experimental research enabled understanding of the pathophysiology of the disease and identified hundreds of potential neuroprotective drugs for treatment, no such drug has shown efficacy in humans. The failure in the translation from bench to bedside has been partially attributed to the poor quality and rigour of animal studies. Recently, it has been suggested that multicentre animal studies imitating the design of randomised clinical trials could improve the translation of experimental research. Magnetic resonance imaging (MRI) could be pivotal in such studies due to its non-invasive nature and its high sensitivity to ischaemic lesions, but its accuracy and concordance across centres has not yet been evaluated. This thesis focussed on the use of MRI for the assessment of late infarct size, the primary outcome used in stroke models. Initially, a systematic review revealed that a plethora of imaging protocols and data analysis methods are used for this purpose. Using meta-analysis techniques, it was determined that T2-weighted imaging (T2WI) was best correlated with gold standard histology for the measurement of infarctbased treatment effects. Then, geometric accuracy in six different preclinical MRI scanners was assessed using structural phantoms and automated data analysis tools developed in-house. It was found that geometric accuracy varies between scanners, particularly when centre-specific T2WI protocols are used instead of a standardised protocol, though longitudinal stability over six months is high. Finally, a simulation study suggested that the measured geometric errors and the different protocols are sufficient to render infarct volumes and related group comparisons across centres incomparable. The variability increases when both factors are taken into account and when infarct volume is expressed as a relative estimate. Data in this study were analysed using a custom-made semi-automated tool that was faster and more reliable in repeated analyses than manual analysis. Findings of this thesis support the implementation of standardised methods for the assessment and optimisation of geometric accuracy in MRI scanners, as well as image acquisition and analysis of in vivo data for the measurement of infarct size in multicentre animal studies. Tools and techniques developed as part of the thesis show great promise in the analysis of phantom and in vivo data and could be a step towards this endeavour.","abstract_has_math":false,"creators":["Milidonis, Xenios"],"institution":"The University of Edinburgh","degree_name":null,"degree_level":null,"degree_discipline":null,"degree_department":null,"school":null,"contributors":[],"advisors":["Marshall, Ian","Macleod, Malcolm"],"committee_chairs":[],"committee_members":[],"year":2017,"date_issued":"2017-07-08","date_published":"2017-07-08","updated_at":"2026-11-19T03:34:36Z","subjects":["stroke","magnetic resonance imaging","MRI","scanner variability","lesions"],"languages":["en"],"rights":[],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"http://hdl.handle.net/1842/28877","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"http://hdl.handle.net/1842/28877","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://era.ed.ac.uk/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Aera.ed.ac.uk%3A1842%2F28877","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Marshall, Ian","Macleod, Malcolm"]},{"key":"dc:contributor.sponsor","label":"Sponsor","values":["other"]},{"key":"dc:creator","label":"Author","values":["Milidonis, Xenios"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2018-03-20T10:59:20Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2018-03-20T10:59:20Z"]},{"key":"dc:date.issued","label":"Date","values":["2017-07-08"]},{"key":"dc:publisher","label":"Institution","values":["The University of Edinburgh"]},{"key":"dc:relation.hasversion","label":"Dc Relation Hasversion","values":["Milidonis, X., Marshall, I., Macleod, M. R., & Sena, E. S. (2015). Magnetic resonance imaging in experimental stroke and comparison with histology: systematic review and meta-analysis. Stroke, 46(3), 843-851. doi:10.1161/STROKEAHA.114.007560","Milidonis, X., Marshall, I., Macleod, M. R., & Sena, E. S. (2015). Magnetic resonance imaging for the assessment of lesion size in experimental stroke: systematic review and meta-analysis. Presented at the 7th Annual Scientific Meeting of the Scottish Imaging Network: A Platform for Scientific Excellence (SINAPSE). Aberdeen, UK.","Milidonis, X., Lennen, R. J., Jansen, M. A., & Marshall, I. (2014). Gradient scaling on preclinical magnetic resonance imaging scanners assessed with a dedicated phantom. Presented at the 20th Annual Scientific Meeting of the British Chapter of the International Society for Magnetic Resonance in Medicine (ISMRM). Edinburgh, UK.","Milidonis, X., McCabe, C., Macrae, M. I., Sena, E. S., Macleod, M. R., & Marshall, I. (2016). Segmentation of infarct on structural MRI data in rodent models of stroke using a semiautomated tool. European Stroke Journal, 1(1), 3-612. doi:10.1177/2396987316642909. Proceedings of the 2nd European Stroke Organisation Conference (p. 404). Barcelona, Spain.","Milidonis, X., McCabe, C., Macrae, M. I., Sena, E. S., Macleod, M. R., & Marshall, I. (2016). Comparison of infarct quantification methods in experimental focal cerebral ischaemia. Cerebrovascular Diseases, 41(1), 1-2. doi:10.1159/000446380. Proceedings of the 25th European Stroke Conference (p. 207). Venice, Italy.","Milidonis, X., Lennen, R. J., Jansen, M. A., Mueller, S., Boehm-Sturm, P., Holmes, W. M., . . . Marshall, I. (2016). Multicenter Evaluation of Geometric Accuracy of MRI Protocols Used in Experimental Stroke. PLOS ONE, 11(9), e0162545. doi:10.1371/journal.pone.0162545","Milidonis, X., Lennen, R. J., Sena, E. S., Macleod, M. R., & Marshall, I. (2015). Accuracy of geometric measurements in high-resolution MRI scanners: between- and within-system evaluation. Presented at the 21st Annual Scientific Meeting of the British Chapter of the International Society for Magnetic Resonance in Medicine (ISMRM). London, UK."]},{"key":"dc:type","label":"Dc Type","values":["Thesis or Dissertation"]},{"key":"dc:type.qualificationlevel","label":"Dc Type Qualificationlevel","values":["Doctoral"]},{"key":"dc:type.qualificationname","label":"Dc Type Qualificationname","values":["PhD Doctor of Philosophy"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["stroke","magnetic resonance imaging","MRI","scanner variability","lesions"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["en"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["http://hdl.handle.net/1842/28877"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["Ischaemic stroke is a leading cause of death and disability in the developed world. Despite that considerable advances in experimental research enabled understanding of the pathophysiology of the disease and identified hundreds of potential neuroprotective drugs for treatment, no such drug has shown efficacy in humans. The failure in the translation from bench to bedside has been partially attributed to the poor quality and rigour of animal studies. Recently, it has been suggested that multicentre animal studies imitating the design of randomised clinical trials could improve the translation of experimental research. Magnetic resonance imaging (MRI) could be pivotal in such studies due to its non-invasive nature and its high sensitivity to ischaemic lesions, but its accuracy and concordance across centres has not yet been evaluated. This thesis focussed on the use of MRI for the assessment of late infarct size, the primary outcome used in stroke models. Initially, a systematic review revealed that a plethora of imaging protocols and data analysis methods are used for this purpose. Using meta-analysis techniques, it was determined that T2-weighted imaging (T2WI) was best correlated with gold standard histology for the measurement of infarctbased treatment effects. Then, geometric accuracy in six different preclinical MRI scanners was assessed using structural phantoms and automated data analysis tools developed in-house. It was found that geometric accuracy varies between scanners, particularly when centre-specific T2WI protocols are used instead of a standardised protocol, though longitudinal stability over six months is high. Finally, a simulation study suggested that the measured geometric errors and the different protocols are sufficient to render infarct volumes and related group comparisons across centres incomparable. The variability increases when both factors are taken into account and when infarct volume is expressed as a relative estimate. Data in this study were analysed using a custom-made semi-automated tool that was faster and more reliable in repeated analyses than manual analysis. Findings of this thesis support the implementation of standardised methods for the assessment and optimisation of geometric accuracy in MRI scanners, as well as image acquisition and analysis of in vivo data for the measurement of infarct size in multicentre animal studies. Tools and techniques developed as part of the thesis show great promise in the analysis of phantom and in vivo data and could be a step towards this endeavour."]},{"key":"dc:title","label":"Title","values":["Multicentre evaluation of MRI variability in the quantification of infarct size in experimental focal cerebral ischaemia"]},{"key":"others:access_status","label":"Others Access Status","values":["open.access"]}]}],"canonical_facts":{"dc:contributor.advisor":["Marshall, Ian","Macleod, Malcolm"],"dc:contributor.sponsor":["other"],"dc:creator":["Milidonis, Xenios"],"dc:date.accessioned":["2018-03-20T10:59:20Z"],"dc:date.available":["2018-03-20T10:59:20Z"],"dc:date.issued":["2017-07-08"],"dc:description.abstract":["Ischaemic stroke is a leading cause of death and disability in the developed world. Despite that considerable advances in experimental research enabled understanding of the pathophysiology of the disease and identified hundreds of potential neuroprotective drugs for treatment, no such drug has shown efficacy in humans. The failure in the translation from bench to bedside has been partially attributed to the poor quality and rigour of animal studies. Recently, it has been suggested that multicentre animal studies imitating the design of randomised clinical trials could improve the translation of experimental research. Magnetic resonance imaging (MRI) could be pivotal in such studies due to its non-invasive nature and its high sensitivity to ischaemic lesions, but its accuracy and concordance across centres has not yet been evaluated. This thesis focussed on the use of MRI for the assessment of late infarct size, the primary outcome used in stroke models. Initially, a systematic review revealed that a plethora of imaging protocols and data analysis methods are used for this purpose. Using meta-analysis techniques, it was determined that T2-weighted imaging (T2WI) was best correlated with gold standard histology for the measurement of infarctbased treatment effects. Then, geometric accuracy in six different preclinical MRI scanners was assessed using structural phantoms and automated data analysis tools developed in-house. It was found that geometric accuracy varies between scanners, particularly when centre-specific T2WI protocols are used instead of a standardised protocol, though longitudinal stability over six months is high. Finally, a simulation study suggested that the measured geometric errors and the different protocols are sufficient to render infarct volumes and related group comparisons across centres incomparable. The variability increases when both factors are taken into account and when infarct volume is expressed as a relative estimate. Data in this study were analysed using a custom-made semi-automated tool that was faster and more reliable in repeated analyses than manual analysis. Findings of this thesis support the implementation of standardised methods for the assessment and optimisation of geometric accuracy in MRI scanners, as well as image acquisition and analysis of in vivo data for the measurement of infarct size in multicentre animal studies. Tools and techniques developed as part of the thesis show great promise in the analysis of phantom and in vivo data and could be a step towards this endeavour."],"dc:identifier.uri":["http://hdl.handle.net/1842/28877"],"dc:language.iso":["en"],"dc:publisher":["The University of Edinburgh"],"dc:relation.hasversion":["Milidonis, X., Marshall, I., Macleod, M. R., & Sena, E. S. (2015). Magnetic resonance imaging in experimental stroke and comparison with histology: systematic review and meta-analysis. Stroke, 46(3), 843-851. doi:10.1161/STROKEAHA.114.007560","Milidonis, X., Marshall, I., Macleod, M. R., & Sena, E. S. (2015). Magnetic resonance imaging for the assessment of lesion size in experimental stroke: systematic review and meta-analysis. Presented at the 7th Annual Scientific Meeting of the Scottish Imaging Network: A Platform for Scientific Excellence (SINAPSE). Aberdeen, UK.","Milidonis, X., Lennen, R. J., Jansen, M. A., & Marshall, I. (2014). Gradient scaling on preclinical magnetic resonance imaging scanners assessed with a dedicated phantom. Presented at the 20th Annual Scientific Meeting of the British Chapter of the International Society for Magnetic Resonance in Medicine (ISMRM). Edinburgh, UK.","Milidonis, X., McCabe, C., Macrae, M. I., Sena, E. S., Macleod, M. R., & Marshall, I. (2016). Segmentation of infarct on structural MRI data in rodent models of stroke using a semiautomated tool. European Stroke Journal, 1(1), 3-612. doi:10.1177/2396987316642909. Proceedings of the 2nd European Stroke Organisation Conference (p. 404). Barcelona, Spain.","Milidonis, X., McCabe, C., Macrae, M. I., Sena, E. S., Macleod, M. R., & Marshall, I. (2016). Comparison of infarct quantification methods in experimental focal cerebral ischaemia. Cerebrovascular Diseases, 41(1), 1-2. doi:10.1159/000446380. Proceedings of the 25th European Stroke Conference (p. 207). Venice, Italy.","Milidonis, X., Lennen, R. J., Jansen, M. A., Mueller, S., Boehm-Sturm, P., Holmes, W. M., . . . Marshall, I. (2016). Multicenter Evaluation of Geometric Accuracy of MRI Protocols Used in Experimental Stroke. PLOS ONE, 11(9), e0162545. doi:10.1371/journal.pone.0162545","Milidonis, X., Lennen, R. J., Sena, E. S., Macleod, M. R., & Marshall, I. (2015). Accuracy of geometric measurements in high-resolution MRI scanners: between- and within-system evaluation. Presented at the 21st Annual Scientific Meeting of the British Chapter of the International Society for Magnetic Resonance in Medicine (ISMRM). London, UK."],"dc:subject":["stroke","magnetic resonance imaging","MRI","scanner variability","lesions"],"dc:title":["Multicentre evaluation of MRI variability in the quantification of infarct size in experimental focal cerebral ischaemia"],"dc:type":["Thesis or Dissertation"],"dc:type.qualificationlevel":["Doctoral"],"dc:type.qualificationname":["PhD Doctor of Philosophy"],"others:access_status":["open.access"]},"updated_at":"2026-11-19T03:34:36Z"}