{"id":{"repo_id":"edinburgh","oai_identifier":"oai:era.ed.ac.uk:1842/30245"},"canonical_url":"https://search.ndltd.org/etd/edinburgh/oai:era.ed.ac.uk:1842/30245","repository":{"repo_id":"edinburgh","name":"University of Edinburgh","base_url":"https://era.ed.ac.uk/server/oai/request"},"display":{"title":"The development and testing of an artificial anal sphincter","abstract":"The physiological mechanisms for achieving fecal continence and the results of the surgical methods to correct incontinence are reviewed. The devices hitherto designed to attempt to achieve continence artificially are discussed and an analysis of 4130 reported complications of a successful device for the control of urinary incontinence (the AMS 800) are presented. Based on these reviews, the need to design and evaluate a prosthetic anal sphincter is identified and such a device is presented in this thesis.","abstract_html":"The physiological mechanisms for achieving fecal continence and the results of the surgical methods to correct incontinence are reviewed. The devices hitherto designed to attempt to achieve continence artificially are discussed and an analysis of 4130 reported complications of a successful device for the control of urinary incontinence (the AMS 800) are presented. Based on these reviews, the need to design and evaluate a prosthetic anal sphincter is identified and such a device is presented in this thesis.","abstract_has_math":false,"creators":["Hajivassiliou, Constantinos Argyrou Papachristodoulou"],"institution":"The University of Edinburgh","degree_name":null,"degree_level":null,"degree_discipline":null,"degree_department":null,"school":null,"contributors":[],"advisors":[],"committee_chairs":[],"committee_members":[],"year":1998,"date_issued":"1998","date_published":"1998","updated_at":"2026-11-18T19:24:38Z","subjects":[],"languages":[],"rights":[],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"https://hdl.handle.net/1842/30245","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"https://hdl.handle.net/1842/30245","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://era.ed.ac.uk/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Aera.ed.ac.uk%3A1842%2F30245","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:creator","label":"Author","values":["Hajivassiliou, Constantinos Argyrou Papachristodoulou"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2018-05-22T12:39:19Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2018-05-22T12:39:19Z"]},{"key":"dc:date.issued","label":"Date","values":["1998"]},{"key":"dc:publisher","label":"Institution","values":["The University of Edinburgh"]},{"key":"dc:relation.ispartof","label":"Dc Relation Ispartof","values":["Annexe Thesis Digitisation Project 2018 Block 19"]},{"key":"dc:relation.isreferencedby","label":"Dc Relation Isreferencedby","values":["Already catalogued"]},{"key":"dc:type","label":"Dc Type","values":["Thesis or Dissertation"]},{"key":"dc:type.qualificationlevel","label":"Dc Type Qualificationlevel","values":["Doctoral"]},{"key":"dc:type.qualificationname","label":"Dc Type Qualificationname","values":["MD Doctor of Medicine"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["http://hdl.handle.net/1842/30245"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["The physiological mechanisms for achieving fecal continence and the results of the surgical methods to correct incontinence are reviewed. The devices hitherto designed to attempt to achieve continence artificially are discussed and an analysis of 4130 reported complications of a successful device for the control of urinary incontinence (the AMS 800) are presented. Based on these reviews, the need to design and evaluate a prosthetic anal sphincter is identified and such a device is presented in this thesis.","The effect of circumferential occlusive pressure on the blood flow of porcine colon was assessed by a Laser Doppler flow meter. It was demonstrated that distal blood flow is reduced by 50% at 52 mmHg. The occlusion pressure required to achieve continence to semi-solids was shown to be reduced by the introduction of angulation both in a theoretical model and experimentally, using a specifically designed fecal substitute.","The Neosphincter was, therefore, designed to simulate the normal physiology of the anorectum by closing and angulating the bowel without causing crenation and ischaemia.","The design parameters of the device were evaluated in an in-vitro model and its placement assessed in a series of acute animal experiments in a porcine model. The effects of the prosthesis set at an operating occlusion pressure of 33-45 mmHg were then evaluated in survival animal experiments by implantation in Yucatan minipigs for up to 20 weeks. The device produced fecal continence in 85% of the activation times without causing ischaemic injury. Mechanical complications associated with the control pump were encountered and design faults were identified. A new pump was designed by the author.","The effect of Neosphincter function on blood flow distribution in the human colon was studied during colectomy using a prototype Laser Doppler flow scanner. Blood flow remained greater than 50% at 60 mmHg occlusion pressure.","d flow remained greater than 50% at 60 mmHg occlusion pressure. The data presented show that the Neosphincter achieves continence in the mini-pig model and further suggest that continence would be achieved in the human without producing intestinal ischaemia. Ethical approval has been obtained to proceed to trials in human patients."]},{"key":"dc:title","label":"Title","values":["The development and testing of an artificial anal sphincter"]},{"key":"others:access_status","label":"Others Access Status","values":["open.access"]}]}],"canonical_facts":{"dc:creator":["Hajivassiliou, Constantinos Argyrou Papachristodoulou"],"dc:date.accessioned":["2018-05-22T12:39:19Z"],"dc:date.available":["2018-05-22T12:39:19Z"],"dc:date.issued":["1998"],"dc:description.abstract":["The physiological mechanisms for achieving fecal continence and the results of the surgical methods to correct incontinence are reviewed. The devices hitherto designed to attempt to achieve continence artificially are discussed and an analysis of 4130 reported complications of a successful device for the control of urinary incontinence (the AMS 800) are presented. Based on these reviews, the need to design and evaluate a prosthetic anal sphincter is identified and such a device is presented in this thesis.","The effect of circumferential occlusive pressure on the blood flow of porcine colon was assessed by a Laser Doppler flow meter. It was demonstrated that distal blood flow is reduced by 50% at 52 mmHg. The occlusion pressure required to achieve continence to semi-solids was shown to be reduced by the introduction of angulation both in a theoretical model and experimentally, using a specifically designed fecal substitute.","The Neosphincter was, therefore, designed to simulate the normal physiology of the anorectum by closing and angulating the bowel without causing crenation and ischaemia.","The design parameters of the device were evaluated in an in-vitro model and its placement assessed in a series of acute animal experiments in a porcine model. The effects of the prosthesis set at an operating occlusion pressure of 33-45 mmHg were then evaluated in survival animal experiments by implantation in Yucatan minipigs for up to 20 weeks. The device produced fecal continence in 85% of the activation times without causing ischaemic injury. Mechanical complications associated with the control pump were encountered and design faults were identified. A new pump was designed by the author.","The effect of Neosphincter function on blood flow distribution in the human colon was studied during colectomy using a prototype Laser Doppler flow scanner. Blood flow remained greater than 50% at 60 mmHg occlusion pressure.","d flow remained greater than 50% at 60 mmHg occlusion pressure. The data presented show that the Neosphincter achieves continence in the mini-pig model and further suggest that continence would be achieved in the human without producing intestinal ischaemia. Ethical approval has been obtained to proceed to trials in human patients."],"dc:identifier.uri":["http://hdl.handle.net/1842/30245"],"dc:publisher":["The University of Edinburgh"],"dc:relation.ispartof":["Annexe Thesis Digitisation Project 2018 Block 19"],"dc:relation.isreferencedby":["Already catalogued"],"dc:title":["The development and testing of an artificial anal sphincter"],"dc:type":["Thesis or Dissertation"],"dc:type.qualificationlevel":["Doctoral"],"dc:type.qualificationname":["MD Doctor of Medicine"],"others:access_status":["open.access"]},"updated_at":"2026-11-18T19:24:38Z"}