{"id":{"repo_id":"edinburgh","oai_identifier":"oai:era.ed.ac.uk:1842/32346"},"canonical_url":"https://search.ndltd.org/etd/edinburgh/oai:era.ed.ac.uk:1842/32346","repository":{"repo_id":"edinburgh","name":"University of Edinburgh","base_url":"https://era.ed.ac.uk/server/oai/request"},"display":{"title":"Observations upon the peripheral circulation","abstract":"PART I.","abstract_html":"PART I.","abstract_has_math":false,"creators":["Grant, Charles Landale"],"institution":"The University of Edinburgh","degree_name":null,"degree_level":null,"degree_discipline":null,"degree_department":null,"school":null,"contributors":[],"advisors":[],"committee_chairs":[],"committee_members":[],"year":1938,"date_issued":"1938","date_published":"1938","updated_at":"2026-11-18T19:27:31Z","subjects":[],"languages":[],"rights":[],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"http://hdl.handle.net/1842/32346","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"http://hdl.handle.net/1842/32346","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://era.ed.ac.uk/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Aera.ed.ac.uk%3A1842%2F32346","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:creator","label":"Author","values":["Grant, Charles Landale"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2018-09-13T15:58:29Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2018-09-13T15:58:29Z"]},{"key":"dc:date.issued","label":"Date","values":["1938"]},{"key":"dc:publisher","label":"Institution","values":["The University of Edinburgh"]},{"key":"dc:relation.ispartof","label":"Dc Relation Ispartof","values":["Annexe Thesis Digitisation Project 2018 Block 20"]},{"key":"dc:type","label":"Dc Type","values":["Thesis or Dissertation"]},{"key":"dc:type.qualificationlevel","label":"Dc Type Qualificationlevel","values":["Doctoral"]},{"key":"dc:type.qualificationname","label":"Dc Type Qualificationname","values":["PhD Doctor of Philosophy"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["http://hdl.handle.net/1842/32346"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["PART I.","The experiments were conducted upon sixty normal individuals, of whom the ages ranged from sixteen to sixty -five years. Six patients were chosen from each age- period of five years.","Vaso- dilatation was induced by the method of Gibbon and Landis, and thereafter, the maximum heat eliminatioh from the hand and foot was estimated by means of calorimeters. The external conditions remained constant throughout the experiments.","The values of the maximum heat elimination varied widely in patients of the same age -period. They were decidedly lower in the older patients.","These observations are discussed, and the value of colorimetry in clinical practice is assessed.","PART II.","The experiments were conducted upon seven young adults.","The state of the muscle circulation was investigated by the indirect method of recording the variations in muscle temperature. An intramuscular thermocouple was used for this purpose.","The state of the skin circulation was investigated at the same time. Thermocouples were again employed.","Vaso- dilatation was induced as before, and the external conditions remained constant throughout the experiments.","From the observations, it was inferred that the vessels of the muscles are normally in a state of tonic contraction, and that the degree of this tonus is quite considerable in conditions of rest.","During the period of induced vaso- dilatation, this tonus is inhibited.","There was evidence that the vessels of the skin and muscles may be controlled by a common mechanism.","PART III.","An attempt was made to correlate the variations in skin and muscle temperature, with the variations in rectal temperature on the assumption that rectal temperature is closely related to blood temperature.","The experiments were conducted upon eleven young adults.","The rectal temperature was ascertained by means of a thermocouple.","In six cases, the heat elimination from the hand and foot was ascertained concurrently by means of calorimeters. In five cases, the skin circulation was investigated by means of thermocouples. Vaso- dilatation was induced in the usual way, and the external conditions remained constant during each experiment.","The results were inconclusive. There was evidence that rectal temperature and blood temperature may vary independently.","The reasons for such independent variation are discussed.","APPENDICES.","They contain the full description of the apparatus and. technics. The constructional details are included in many instances.","Three aspects of the construction receive special attention: -","(1) The ether- vapour thermostat - a modification of the usual J -tube is described.","(2) The mercury relay battery circuit - a safety device is described which has been referred to as the \"booster\" battery.","(3) The circuit of a multiple thermocouple system - the question of reciprocal interference is discussed and the methods of its prevention are described."]},{"key":"dc:title","label":"Title","values":["Observations upon the peripheral circulation"]},{"key":"others:access_status","label":"Others Access Status","values":["open.access"]}]}],"canonical_facts":{"dc:creator":["Grant, Charles Landale"],"dc:date.accessioned":["2018-09-13T15:58:29Z"],"dc:date.available":["2018-09-13T15:58:29Z"],"dc:date.issued":["1938"],"dc:description.abstract":["PART I.","The experiments were conducted upon sixty normal individuals, of whom the ages ranged from sixteen to sixty -five years. Six patients were chosen from each age- period of five years.","Vaso- dilatation was induced by the method of Gibbon and Landis, and thereafter, the maximum heat eliminatioh from the hand and foot was estimated by means of calorimeters. The external conditions remained constant throughout the experiments.","The values of the maximum heat elimination varied widely in patients of the same age -period. They were decidedly lower in the older patients.","These observations are discussed, and the value of colorimetry in clinical practice is assessed.","PART II.","The experiments were conducted upon seven young adults.","The state of the muscle circulation was investigated by the indirect method of recording the variations in muscle temperature. An intramuscular thermocouple was used for this purpose.","The state of the skin circulation was investigated at the same time. Thermocouples were again employed.","Vaso- dilatation was induced as before, and the external conditions remained constant throughout the experiments.","From the observations, it was inferred that the vessels of the muscles are normally in a state of tonic contraction, and that the degree of this tonus is quite considerable in conditions of rest.","During the period of induced vaso- dilatation, this tonus is inhibited.","There was evidence that the vessels of the skin and muscles may be controlled by a common mechanism.","PART III.","An attempt was made to correlate the variations in skin and muscle temperature, with the variations in rectal temperature on the assumption that rectal temperature is closely related to blood temperature.","The experiments were conducted upon eleven young adults.","The rectal temperature was ascertained by means of a thermocouple.","In six cases, the heat elimination from the hand and foot was ascertained concurrently by means of calorimeters. In five cases, the skin circulation was investigated by means of thermocouples. Vaso- dilatation was induced in the usual way, and the external conditions remained constant during each experiment.","The results were inconclusive. There was evidence that rectal temperature and blood temperature may vary independently.","The reasons for such independent variation are discussed.","APPENDICES.","They contain the full description of the apparatus and. technics. The constructional details are included in many instances.","Three aspects of the construction receive special attention: -","(1) The ether- vapour thermostat - a modification of the usual J -tube is described.","(2) The mercury relay battery circuit - a safety device is described which has been referred to as the \"booster\" battery.","(3) The circuit of a multiple thermocouple system - the question of reciprocal interference is discussed and the methods of its prevention are described."],"dc:identifier.uri":["http://hdl.handle.net/1842/32346"],"dc:publisher":["The University of Edinburgh"],"dc:relation.ispartof":["Annexe Thesis Digitisation Project 2018 Block 20"],"dc:title":["Observations upon the peripheral circulation"],"dc:type":["Thesis or Dissertation"],"dc:type.qualificationlevel":["Doctoral"],"dc:type.qualificationname":["PhD Doctor of Philosophy"],"others:access_status":["open.access"]},"updated_at":"2026-11-18T19:27:31Z"}