{"id":{"repo_id":"edinburgh","oai_identifier":"oai:era.ed.ac.uk:1842/33557"},"canonical_url":"https://search.ndltd.org/etd/edinburgh/oai:era.ed.ac.uk:1842/33557","repository":{"repo_id":"edinburgh","name":"University of Edinburgh","base_url":"https://era.ed.ac.uk/server/oai/request"},"display":{"title":"Studies in haematology","abstract":"For convenience we may divide haemolytic systems into three large classes. (I) Systems in which all the components are known, and in which every component can be sub j e t ed to exact and direct measurement , as, for example, a system containing saline, saponin, and cells, or a system containing saline, saponin, serum, cells, and acetic acid. In such systems there is no doubt about the Quantity of any component present. (2) Systems in which there is one- component the quantity of which can be ascertained only by indirect methods; as, for instance, a system containing cells, saline, silìc acid, and complement. The quantity of complement present cannot be measured directly in any simple physical units, and can be found only by taking account of (a) the amount of complement containing serum. added, and (b) the activity of this serum. The conception of 'activity' at once introduces a difficulty. (3) Systems in which more than one component is incapable of direct measurement, as a system of cells in saline, complement, and amboceptor. A haemolytic system of type (1) we shall call a simple haemolytic system; the kinetics of such a system we propose to study in some detail.","abstract_html":"For convenience we may divide haemolytic systems into three large classes. (I) Systems in which all the components are known, and in which every component can be sub j e t ed to exact and direct measurement , as, for example, a system containing saline, saponin, and cells, or a system containing saline, saponin, serum, cells, and acetic acid. In such systems there is no doubt about the Quantity of any component present. (2) Systems in which there is one- component the quantity of which can be ascertained only by indirect methods; as, for instance, a system containing cells, saline, silìc acid, and complement. The quantity of complement present cannot be measured directly in any simple physical units, and can be found only by taking account of (a) the amount of complement containing serum. added, and (b) the activity of this serum. The conception of &#x27;activity&#x27; at once introduces a difficulty. (3) Systems in which more than one component is incapable of direct measurement, as a system of cells in saline, complement, and amboceptor. A haemolytic system of type (1) we shall call a simple haemolytic system; the kinetics of such a system we propose to study in some detail.","abstract_has_math":false,"creators":["Ponder, Eric"],"institution":"The University of Edinburgh","degree_name":null,"degree_level":null,"degree_discipline":null,"degree_department":null,"school":null,"contributors":[],"advisors":[],"committee_chairs":[],"committee_members":[],"year":1926,"date_issued":"1926","date_published":"1926","updated_at":"2026-11-18T19:25:56Z","subjects":[],"languages":[],"rights":[],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"http://hdl.handle.net/1842/33557","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"http://hdl.handle.net/1842/33557","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://era.ed.ac.uk/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Aera.ed.ac.uk%3A1842%2F33557","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:creator","label":"Author","values":["Ponder, Eric"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2019-02-15T14:16:57Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2019-02-15T14:16:57Z"]},{"key":"dc:date.issued","label":"Date","values":["1926"]},{"key":"dc:publisher","label":"Institution","values":["The University of Edinburgh"]},{"key":"dc:relation.ispartof","label":"Dc Relation Ispartof","values":["Annexe Thesis Digitisation Project 2019 Block 22"]},{"key":"dc:type","label":"Dc Type","values":["Thesis or Dissertation"]},{"key":"dc:type.qualificationlevel","label":"Dc Type Qualificationlevel","values":["Doctoral"]},{"key":"dc:type.qualificationname","label":"Dc Type Qualificationname","values":["MD Doctor of Medicine"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["http://hdl.handle.net/1842/33557"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["For convenience we may divide haemolytic systems into three large classes. (I) Systems in which all the components are known, and in which every component can be sub j e t ed to exact and direct measurement , as, for example, a system containing saline, saponin, and cells, or a system containing saline, saponin, serum, cells, and acetic acid. In such systems there is no doubt about the Quantity of any component present. (2) Systems in which there is one- component the quantity of which can be ascertained only by indirect methods; as, for instance, a system containing cells, saline, silìc acid, and complement. The quantity of complement present cannot be measured directly in any simple physical units, and can be found only by taking account of (a) the amount of complement containing serum. added, and (b) the activity of this serum. The conception of 'activity' at once introduces a difficulty. (3) Systems in which more than one component is incapable of direct measurement, as a system of cells in saline, complement, and amboceptor. A haemolytic system of type (1) we shall call a simple haemolytic system; the kinetics of such a system we propose to study in some detail."]},{"key":"dc:title","label":"Title","values":["Studies in haematology"]},{"key":"others:access_status","label":"Others Access Status","values":["open.access"]}]}],"canonical_facts":{"dc:creator":["Ponder, Eric"],"dc:date.accessioned":["2019-02-15T14:16:57Z"],"dc:date.available":["2019-02-15T14:16:57Z"],"dc:date.issued":["1926"],"dc:description.abstract":["For convenience we may divide haemolytic systems into three large classes. (I) Systems in which all the components are known, and in which every component can be sub j e t ed to exact and direct measurement , as, for example, a system containing saline, saponin, and cells, or a system containing saline, saponin, serum, cells, and acetic acid. In such systems there is no doubt about the Quantity of any component present. (2) Systems in which there is one- component the quantity of which can be ascertained only by indirect methods; as, for instance, a system containing cells, saline, silìc acid, and complement. The quantity of complement present cannot be measured directly in any simple physical units, and can be found only by taking account of (a) the amount of complement containing serum. added, and (b) the activity of this serum. The conception of 'activity' at once introduces a difficulty. (3) Systems in which more than one component is incapable of direct measurement, as a system of cells in saline, complement, and amboceptor. A haemolytic system of type (1) we shall call a simple haemolytic system; the kinetics of such a system we propose to study in some detail."],"dc:identifier.uri":["http://hdl.handle.net/1842/33557"],"dc:publisher":["The University of Edinburgh"],"dc:relation.ispartof":["Annexe Thesis Digitisation Project 2019 Block 22"],"dc:title":["Studies in haematology"],"dc:type":["Thesis or Dissertation"],"dc:type.qualificationlevel":["Doctoral"],"dc:type.qualificationname":["MD Doctor of Medicine"],"others:access_status":["open.access"]},"updated_at":"2026-11-18T19:25:56Z"}