{"id":{"repo_id":"edinburgh","oai_identifier":"oai:era.ed.ac.uk:1842/33750"},"canonical_url":"https://search.ndltd.org/etd/edinburgh/oai:era.ed.ac.uk:1842/33750","repository":{"repo_id":"edinburgh","name":"University of Edinburgh","base_url":"https://era.ed.ac.uk/server/oai/request"},"display":{"title":"The correlation of vital capacity readings and clinical examination: with special reference to vital capacity observations in obese subjects","abstract":"After taking many hundreds of observations of vital lung capacity, the following conclusions are arrived at :-","abstract_html":"After taking many hundreds of observations of vital lung capacity, the following conclusions are arrived at :-","abstract_has_math":false,"creators":["Rolt, John B."],"institution":"The University of Edinburgh","degree_name":null,"degree_level":null,"degree_discipline":null,"degree_department":null,"school":null,"contributors":[],"advisors":[],"committee_chairs":[],"committee_members":[],"year":1930,"date_issued":"1930","date_published":"1930","updated_at":"2026-11-18T19:27:08Z","subjects":[],"languages":[],"rights":[],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"https://hdl.handle.net/1842/33750","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"https://hdl.handle.net/1842/33750","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://era.ed.ac.uk/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Aera.ed.ac.uk%3A1842%2F33750","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:creator","label":"Author","values":["Rolt, John B."]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2019-02-15T14:19:10Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2019-02-15T14:19:10Z"]},{"key":"dc:date.issued","label":"Date","values":["1930"]},{"key":"dc:publisher","label":"Institution","values":["The University of Edinburgh"]},{"key":"dc:relation.ispartof","label":"Dc Relation Ispartof","values":["Annexe Thesis Digitisation Project 2019 Block 22"]},{"key":"dc:type","label":"Dc Type","values":["Thesis or Dissertation"]},{"key":"dc:type.qualificationlevel","label":"Dc Type Qualificationlevel","values":["Doctoral"]},{"key":"dc:type.qualificationname","label":"Dc Type Qualificationname","values":["MD Doctor of Medicine"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["http://hdl.handle.net/1842/33750"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["After taking many hundreds of observations of vital lung capacity, the following conclusions are arrived at :-","(1) Individual variations present one of the greatest drawbacks to the value of vital capacity readings.","It is necessary to know the individuals own standard while in health, before anything like complete reliance can be placed on an observation taken from a patient suffering from disease of the heart or lungs.","(2) The normal standards at present in use tend to be unreliable as a very large class of people do not conform to the so called normal body build.","(3) Standards based on surface area are probably the most accurate, but for quick clinical work the Height Standard is satisfactory.","(4) Lack of co- operation on the part of the patient is the chief factor militating against reliable readings.","(5) Vital capacity readings must in no sense be used as a short cut to diagnosis. An observation not in accordance with clinical findings should be looked on with suspicion.","(6) Anthracosis appears to have no effect on the vital capacity.","(7) Vital capacity readings give no indication of physical fitness except in so far as the heart and lungs are concerned.","(8) In acute heart failure the vital capacity follows very closely on the daily changes in the patient's clinical condition but in general it may be said that no undue weight should be attached to a sudden unexpectedly low reading unless it can be confirmed by clinical findings.","(9) As a class obese subjects have low vital capacities but considerable individual variation is met with.","In the obese person the vital capacity increases as the weight is reduced.","(10) In working with obese patients the Height Standard, or the Surface area standard using the patients correct weight, may be used.","If the Surface area standard and the patient's observed weight be employed it is suggested that 135 be added to the observed vital capacity instead of 20% advocated by BOWEN & PLATT.","(11) It would appear that more than one factor is at work in causing a reduction of vital capacity in the obese subject.","Vital capacity readings are of questionable value in diagnosing myocardial changes in the obese.","(12) Definite Electro cardiographic changes were observed in obese subjects. A satisfactory explanation has not been found but these changes seem to be of sufficient importance to warrant further investigation."]},{"key":"dc:title","label":"Title","values":["The correlation of vital capacity readings and clinical examination: with special reference to vital capacity observations in obese subjects"]},{"key":"others:access_status","label":"Others Access Status","values":["open.access"]}]}],"canonical_facts":{"dc:creator":["Rolt, John B."],"dc:date.accessioned":["2019-02-15T14:19:10Z"],"dc:date.available":["2019-02-15T14:19:10Z"],"dc:date.issued":["1930"],"dc:description.abstract":["After taking many hundreds of observations of vital lung capacity, the following conclusions are arrived at :-","(1) Individual variations present one of the greatest drawbacks to the value of vital capacity readings.","It is necessary to know the individuals own standard while in health, before anything like complete reliance can be placed on an observation taken from a patient suffering from disease of the heart or lungs.","(2) The normal standards at present in use tend to be unreliable as a very large class of people do not conform to the so called normal body build.","(3) Standards based on surface area are probably the most accurate, but for quick clinical work the Height Standard is satisfactory.","(4) Lack of co- operation on the part of the patient is the chief factor militating against reliable readings.","(5) Vital capacity readings must in no sense be used as a short cut to diagnosis. An observation not in accordance with clinical findings should be looked on with suspicion.","(6) Anthracosis appears to have no effect on the vital capacity.","(7) Vital capacity readings give no indication of physical fitness except in so far as the heart and lungs are concerned.","(8) In acute heart failure the vital capacity follows very closely on the daily changes in the patient's clinical condition but in general it may be said that no undue weight should be attached to a sudden unexpectedly low reading unless it can be confirmed by clinical findings.","(9) As a class obese subjects have low vital capacities but considerable individual variation is met with.","In the obese person the vital capacity increases as the weight is reduced.","(10) In working with obese patients the Height Standard, or the Surface area standard using the patients correct weight, may be used.","If the Surface area standard and the patient's observed weight be employed it is suggested that 135 be added to the observed vital capacity instead of 20% advocated by BOWEN & PLATT.","(11) It would appear that more than one factor is at work in causing a reduction of vital capacity in the obese subject.","Vital capacity readings are of questionable value in diagnosing myocardial changes in the obese.","(12) Definite Electro cardiographic changes were observed in obese subjects. A satisfactory explanation has not been found but these changes seem to be of sufficient importance to warrant further investigation."],"dc:identifier.uri":["http://hdl.handle.net/1842/33750"],"dc:publisher":["The University of Edinburgh"],"dc:relation.ispartof":["Annexe Thesis Digitisation Project 2019 Block 22"],"dc:title":["The correlation of vital capacity readings and clinical examination: with special reference to vital capacity observations in obese subjects"],"dc:type":["Thesis or Dissertation"],"dc:type.qualificationlevel":["Doctoral"],"dc:type.qualificationname":["MD Doctor of Medicine"],"others:access_status":["open.access"]},"updated_at":"2026-11-18T19:27:08Z"}