{"id":{"repo_id":"edinburgh","oai_identifier":"oai:era.ed.ac.uk:1842/35101"},"canonical_url":"https://search.ndltd.org/etd/edinburgh/oai:era.ed.ac.uk:1842/35101","repository":{"repo_id":"edinburgh","name":"University of Edinburgh","base_url":"https://era.ed.ac.uk/server/oai/request"},"display":{"title":"Intra-ocular tension and the general blood pressure: with special reference to the aetiology of glaucoma","abstract":"The question of the relation of blood pressure to intra-ocular pressure has been entered into by more than one observer. My excuse for approaching the same subject again is that, on the one hand, our means of estimating blood pressure clinically have been improved since most of these previous investigations were made and, on the other, that the recent invention of Schiötz's tonometer has given us an instrument whereby we are able clinically to note with accuracy the smallest rise or fall in the intra-ocular pressure . So far as I Know, none of those who have studied this subject before have used (or at least have recorded their use of) the tonometer in conjunction with the sphygmomanometer, while the most recent writer on the subject, Kummell, has stated that some light may be shed on this admittedly difficult problem by such an investigation. The thesis falls into four main divisions. (1) Tonometry. (2) Blood Pressure Measurement. (3) The relation of the Blood Pressure to the Eye Pressure. (4) The question of the place high Blood Pressure has in the aetiology of Glaucoma.","abstract_html":"The question of the relation of blood pressure to intra-ocular pressure has been entered into by more than one observer. My excuse for approaching the same subject again is that, on the one hand, our means of estimating blood pressure clinically have been improved since most of these previous investigations were made and, on the other, that the recent invention of Schiötz&#x27;s tonometer has given us an instrument whereby we are able clinically to note with accuracy the smallest rise or fall in the intra-ocular pressure . So far as I Know, none of those who have studied this subject before have used (or at least have recorded their use of) the tonometer in conjunction with the sphygmomanometer, while the most recent writer on the subject, Kummell, has stated that some light may be shed on this admittedly difficult problem by such an investigation. The thesis falls into four main divisions. (1) Tonometry. (2) Blood Pressure Measurement. (3) The relation of the Blood Pressure to the Eye Pressure. (4) The question of the place high Blood Pressure has in the aetiology of Glaucoma.","abstract_has_math":false,"creators":["MacRae, Alexander"],"institution":"The University of Edinburgh","degree_name":null,"degree_level":null,"degree_discipline":null,"degree_department":null,"school":null,"contributors":[],"advisors":[],"committee_chairs":[],"committee_members":[],"year":1912,"date_issued":"1912","date_published":"1912","updated_at":"2026-11-18T19:24:17Z","subjects":[],"languages":[],"rights":[],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"http://hdl.handle.net/1842/35101","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"http://hdl.handle.net/1842/35101","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://era.ed.ac.uk/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Aera.ed.ac.uk%3A1842%2F35101","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:creator","label":"Author","values":["MacRae, Alexander"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2019-02-15T14:34:42Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2019-02-15T14:34:42Z"]},{"key":"dc:date.issued","label":"Date","values":["1912"]},{"key":"dc:publisher","label":"Institution","values":["The University of Edinburgh"]},{"key":"dc:relation.ispartof","label":"Dc Relation Ispartof","values":["Annexe Thesis Digitisation Project 2019 Block 22"]},{"key":"dc:type","label":"Dc Type","values":["Thesis or Dissertation"]},{"key":"dc:type.qualificationlevel","label":"Dc Type Qualificationlevel","values":["Doctoral"]},{"key":"dc:type.qualificationname","label":"Dc Type Qualificationname","values":["MD Doctor of Medicine"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["http://hdl.handle.net/1842/35101"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["The question of the relation of blood pressure to intra-ocular pressure has been entered into by more than one observer. My excuse for approaching the same subject again is that, on the one hand, our means of estimating blood pressure clinically have been improved since most of these previous investigations were made and, on the other, that the recent invention of Schiötz's tonometer has given us an instrument whereby we are able clinically to note with accuracy the smallest rise or fall in the intra-ocular pressure . So far as I Know, none of those who have studied this subject before have used (or at least have recorded their use of) the tonometer in conjunction with the sphygmomanometer, while the most recent writer on the subject, Kummell, has stated that some light may be shed on this admittedly difficult problem by such an investigation. The thesis falls into four main divisions. (1) Tonometry. (2) Blood Pressure Measurement. (3) The relation of the Blood Pressure to the Eye Pressure. (4) The question of the place high Blood Pressure has in the aetiology of Glaucoma."]},{"key":"dc:title","label":"Title","values":["Intra-ocular tension and the general blood pressure: with special reference to the aetiology of glaucoma"]},{"key":"others:access_status","label":"Others Access Status","values":["open.access"]}]}],"canonical_facts":{"dc:creator":["MacRae, Alexander"],"dc:date.accessioned":["2019-02-15T14:34:42Z"],"dc:date.available":["2019-02-15T14:34:42Z"],"dc:date.issued":["1912"],"dc:description.abstract":["The question of the relation of blood pressure to intra-ocular pressure has been entered into by more than one observer. My excuse for approaching the same subject again is that, on the one hand, our means of estimating blood pressure clinically have been improved since most of these previous investigations were made and, on the other, that the recent invention of Schiötz's tonometer has given us an instrument whereby we are able clinically to note with accuracy the smallest rise or fall in the intra-ocular pressure . So far as I Know, none of those who have studied this subject before have used (or at least have recorded their use of) the tonometer in conjunction with the sphygmomanometer, while the most recent writer on the subject, Kummell, has stated that some light may be shed on this admittedly difficult problem by such an investigation. The thesis falls into four main divisions. (1) Tonometry. (2) Blood Pressure Measurement. (3) The relation of the Blood Pressure to the Eye Pressure. (4) The question of the place high Blood Pressure has in the aetiology of Glaucoma."],"dc:identifier.uri":["http://hdl.handle.net/1842/35101"],"dc:publisher":["The University of Edinburgh"],"dc:relation.ispartof":["Annexe Thesis Digitisation Project 2019 Block 22"],"dc:title":["Intra-ocular tension and the general blood pressure: with special reference to the aetiology of glaucoma"],"dc:type":["Thesis or Dissertation"],"dc:type.qualificationlevel":["Doctoral"],"dc:type.qualificationname":["MD Doctor of Medicine"],"others:access_status":["open.access"]},"updated_at":"2026-11-18T19:24:17Z"}