{"id":{"repo_id":"edinburgh","oai_identifier":"oai:era.ed.ac.uk:1842/45432"},"canonical_url":"https://search.ndltd.org/etd/edinburgh/oai:era.ed.ac.uk:1842/45432","repository":{"repo_id":"edinburgh","name":"University of Edinburgh","base_url":"https://era.ed.ac.uk/server/oai/request"},"display":{"title":"Development of a novel in vitro ureter model to investigate urinary tract infections","abstract":"Urinary tract infections (UTIs) affect approximately 150 million individuals worldwide each year. Several in vitro models exist for studying bladder biology and infection but there is a lack of a physiologically relevant human ureter model, which limits the study of ureter-specific disease mechanisms and the development of targeted therapies. Most existing in vitro approaches are two-dimensional cell cultures or simplified collagen-based tubular constructs, which do not replicate the multi-layered and multi-cellular architecture of the ureter. This thesis develops a three-dimensional ureter model using a novel technology termed rotational internal flow layer engineering (RIFLE), which produces layered tubular structures with cells positioned in defined layers. The model was assembled by positioning collagen containing fibroblasts, smooth muscle cells, and epithelial cells into layers. L929 fibroblasts represented the outer adventitial and inner stromal layers, human smooth muscle cells the medial muscularis layer, and Madin-Darby canine kidney (MDCK) epithelial cells represented the luminal epithelium. Three-dimensional confocal imaging confirmed that the three cell types were positioned in layers that resembled the hierarchical cellular arrangement in the human ureter. To make the model better suited for studying bacterial interactions in UTIs, the luminal layer was then modified by replacing the MDCK cells with human 5637 bladder cancer cells, which express uroplakins that uropathogenic Escherichia coli (UPEC) strains use to attach. Further, histology studies indicated that the engineered ureter more closely resembled an embryonic ureter than a mature ureter. In parallel, recombinant SpyTag/SpyCatcher protein hydrogels were explored to improve the mechanical properties of the collagen matrix. Although these hydrogels could be fabricated into tubular structures using RIFLE, poor cell viability, most likely due to endotoxins contaminating the bacterially-produced SpyTag/SpyCatcher proteins, prevented their incorporation into the collagen-based construct. Overall, this thesis develops the first version of a three-dimensional, multi-layered ureter model that positions relevant cell types arranged within microscale collagen layers. It provides a platform to study ureter-specific infection biology, barrier function and drug testing, and a possible alternative to animal models for preclinical work.","abstract_html":"Urinary tract infections (UTIs) affect approximately 150 million individuals worldwide each year. Several in vitro models exist for studying bladder biology and infection but there is a lack of a physiologically relevant human ureter model, which limits the study of ureter-specific disease mechanisms and the development of targeted therapies. Most existing in vitro approaches are two-dimensional cell cultures or simplified collagen-based tubular constructs, which do not replicate the multi-layered and multi-cellular architecture of the ureter. This thesis develops a three-dimensional ureter model using a novel technology termed rotational internal flow layer engineering (RIFLE), which produces layered tubular structures with cells positioned in defined layers. The model was assembled by positioning collagen containing fibroblasts, smooth muscle cells, and epithelial cells into layers. L929 fibroblasts represented the outer adventitial and inner stromal layers, human smooth muscle cells the medial muscularis layer, and Madin-Darby canine kidney (MDCK) epithelial cells represented the luminal epithelium. Three-dimensional confocal imaging confirmed that the three cell types were positioned in layers that resembled the hierarchical cellular arrangement in the human ureter. To make the model better suited for studying bacterial interactions in UTIs, the luminal layer was then modified by replacing the MDCK cells with human 5637 bladder cancer cells, which express uroplakins that uropathogenic Escherichia coli (UPEC) strains use to attach. Further, histology studies indicated that the engineered ureter more closely resembled an embryonic ureter than a mature ureter. In parallel, recombinant SpyTag/SpyCatcher protein hydrogels were explored to improve the mechanical properties of the collagen matrix. Although these hydrogels could be fabricated into tubular structures using RIFLE, poor cell viability, most likely due to endotoxins contaminating the bacterially-produced SpyTag/SpyCatcher proteins, prevented their incorporation into the collagen-based construct. Overall, this thesis develops the first version of a three-dimensional, multi-layered ureter model that positions relevant cell types arranged within microscale collagen layers. It provides a platform to study ureter-specific infection biology, barrier function and drug testing, and a possible alternative to animal models for preclinical work.","abstract_has_math":false,"creators":["Ravi, Sneha"],"institution":null,"degree_name":null,"degree_level":null,"degree_discipline":null,"degree_department":null,"school":null,"contributors":[],"advisors":["Davies, Jamie","Dimartino, Simone","Holland, Ian","Hadoke, Patrick","Regan, Lynne"],"committee_chairs":[],"committee_members":[],"year":2026,"date_issued":"2026-10-30","date_published":"2026-10-30","updated_at":"2026-11-18T19:26:27Z","subjects":["Urinary tract infections (UTIs)","UTIs","Ureter model","Rotational Internal Flow Layer Engineering (RIFLE)","RIFLE","Three-dimensional tissue engineering","Uropathogenic Escherichia coli (UPEC)","UPEC"],"languages":["en"],"rights":[],"rights_urls":[],"identifier_entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://doi.org/10.7488/era/7946"],"render_values":[{"text":"https://doi.org/10.7488/era/7946","href":"https://doi.org/10.7488/era/7946","code":true}]}],"person_identifier_entries":[]},"links":{"outbound_url":"https://hdl.handle.net/1842/45432","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"https://hdl.handle.net/1842/45432","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://era.ed.ac.uk/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Aera.ed.ac.uk%3A1842%2F45432","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Davies, Jamie","Dimartino, Simone","Holland, Ian","Hadoke, Patrick","Regan, Lynne"]},{"key":"dc:creator","label":"Author","values":["Ravi, Sneha"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2026-10-30T14:49:42Z"]},{"key":"dc:date.issued","label":"Date","values":["2026-10-30"]},{"key":"dc:relation.hasversion","label":"Dc Relation Hasversion","values":["West, G., Ravi, S., Davies, J. A., & Holland, I. (2025). Semi-automated layer-by-layer biofabrication using rotational internal flow layer engineering technology. SLAS Technology, 31, 100256. https://doi.org/10.1016/j.slast.2025.100256"]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]},{"key":"dc:type.qualificationlevel","label":"Dc Type Qualificationlevel","values":["Doctoral"]},{"key":"dc:type.qualificationname","label":"Dc Type Qualificationname","values":["PhD Doctor of Philosophy"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Urinary tract infections (UTIs)","UTIs","Ureter model","Rotational Internal Flow Layer Engineering (RIFLE)","RIFLE","Three-dimensional tissue engineering","Uropathogenic Escherichia coli (UPEC)","UPEC"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["en"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://hdl.handle.net/1842/45432","https://doi.org/10.7488/era/7946"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["Urinary tract infections (UTIs) affect approximately 150 million individuals worldwide each year. Several in vitro models exist for studying bladder biology and infection but there is a lack of a physiologically relevant human ureter model, which limits the study of ureter-specific disease mechanisms and the development of targeted therapies. Most existing in vitro approaches are two-dimensional cell cultures or simplified collagen-based tubular constructs, which do not replicate the multi-layered and multi-cellular architecture of the ureter. This thesis develops a three-dimensional ureter model using a novel technology termed rotational internal flow layer engineering (RIFLE), which produces layered tubular structures with cells positioned in defined layers. The model was assembled by positioning collagen containing fibroblasts, smooth muscle cells, and epithelial cells into layers. L929 fibroblasts represented the outer adventitial and inner stromal layers, human smooth muscle cells the medial muscularis layer, and Madin-Darby canine kidney (MDCK) epithelial cells represented the luminal epithelium. Three-dimensional confocal imaging confirmed that the three cell types were positioned in layers that resembled the hierarchical cellular arrangement in the human ureter. To make the model better suited for studying bacterial interactions in UTIs, the luminal layer was then modified by replacing the MDCK cells with human 5637 bladder cancer cells, which express uroplakins that uropathogenic Escherichia coli (UPEC) strains use to attach. Further, histology studies indicated that the engineered ureter more closely resembled an embryonic ureter than a mature ureter. In parallel, recombinant SpyTag/SpyCatcher protein hydrogels were explored to improve the mechanical properties of the collagen matrix. Although these hydrogels could be fabricated into tubular structures using RIFLE, poor cell viability, most likely due to endotoxins contaminating the bacterially-produced SpyTag/SpyCatcher proteins, prevented their incorporation into the collagen-based construct. Overall, this thesis develops the first version of a three-dimensional, multi-layered ureter model that positions relevant cell types arranged within microscale collagen layers. It provides a platform to study ureter-specific infection biology, barrier function and drug testing, and a possible alternative to animal models for preclinical work."]},{"key":"dc:title","label":"Title","values":["Development of a novel in vitro ureter model to investigate urinary tract infections"]},{"key":"others:access_status","label":"Others Access Status","values":["open.access"]}]}],"canonical_facts":{"dc:contributor.advisor":["Davies, Jamie","Dimartino, Simone","Holland, Ian","Hadoke, Patrick","Regan, Lynne"],"dc:creator":["Ravi, Sneha"],"dc:date.accessioned":["2026-10-30T14:49:42Z"],"dc:date.issued":["2026-10-30"],"dc:description.abstract":["Urinary tract infections (UTIs) affect approximately 150 million individuals worldwide each year. Several in vitro models exist for studying bladder biology and infection but there is a lack of a physiologically relevant human ureter model, which limits the study of ureter-specific disease mechanisms and the development of targeted therapies. Most existing in vitro approaches are two-dimensional cell cultures or simplified collagen-based tubular constructs, which do not replicate the multi-layered and multi-cellular architecture of the ureter. This thesis develops a three-dimensional ureter model using a novel technology termed rotational internal flow layer engineering (RIFLE), which produces layered tubular structures with cells positioned in defined layers. The model was assembled by positioning collagen containing fibroblasts, smooth muscle cells, and epithelial cells into layers. L929 fibroblasts represented the outer adventitial and inner stromal layers, human smooth muscle cells the medial muscularis layer, and Madin-Darby canine kidney (MDCK) epithelial cells represented the luminal epithelium. Three-dimensional confocal imaging confirmed that the three cell types were positioned in layers that resembled the hierarchical cellular arrangement in the human ureter. To make the model better suited for studying bacterial interactions in UTIs, the luminal layer was then modified by replacing the MDCK cells with human 5637 bladder cancer cells, which express uroplakins that uropathogenic Escherichia coli (UPEC) strains use to attach. Further, histology studies indicated that the engineered ureter more closely resembled an embryonic ureter than a mature ureter. In parallel, recombinant SpyTag/SpyCatcher protein hydrogels were explored to improve the mechanical properties of the collagen matrix. Although these hydrogels could be fabricated into tubular structures using RIFLE, poor cell viability, most likely due to endotoxins contaminating the bacterially-produced SpyTag/SpyCatcher proteins, prevented their incorporation into the collagen-based construct. Overall, this thesis develops the first version of a three-dimensional, multi-layered ureter model that positions relevant cell types arranged within microscale collagen layers. It provides a platform to study ureter-specific infection biology, barrier function and drug testing, and a possible alternative to animal models for preclinical work."],"dc:identifier.uri":["https://hdl.handle.net/1842/45432","https://doi.org/10.7488/era/7946"],"dc:language.iso":["en"],"dc:relation.hasversion":["West, G., Ravi, S., Davies, J. A., & Holland, I. (2025). Semi-automated layer-by-layer biofabrication using rotational internal flow layer engineering technology. SLAS Technology, 31, 100256. https://doi.org/10.1016/j.slast.2025.100256"],"dc:subject":["Urinary tract infections (UTIs)","UTIs","Ureter model","Rotational Internal Flow Layer Engineering (RIFLE)","RIFLE","Three-dimensional tissue engineering","Uropathogenic Escherichia coli (UPEC)","UPEC"],"dc:title":["Development of a novel in vitro ureter model to investigate urinary tract infections"],"dc:type":["Thesis"],"dc:type.qualificationlevel":["Doctoral"],"dc:type.qualificationname":["PhD Doctor of Philosophy"],"others:access_status":["open.access"]},"updated_at":"2026-11-18T19:26:27Z"}