{"id":{"repo_id":"edithcowan","oai_identifier":"oai:ro.ecu.edu.au:theses-2712"},"canonical_url":"https://search.ndltd.org/etd/edithcowan/oai:ro.ecu.edu.au:theses-2712","repository":{"repo_id":"edithcowan","name":"Edith Cowan University","base_url":"https://ro.ecu.edu.au/do/oai/"},"display":{"title":"Accurate modelling and positioning of a magnetically-controlled catheter tip","abstract":"This thesis represents the initial phase of a proposed operator and patient friendly method designed to semi-automate the positioning and directing of an intravascular catheter in the human heart using a variable electromagnetically induced field to control a catheter tip equipped with three tiny fixed magnets oriented in XYZ planes. Here we demonstrate a comprehensive mathematical model which accurately calculates the magnetic field generated by the electromagnet system, and the magnetic torques and forces exerted on a three-magnet tip catheter. From this we have developed an iterative predictive computer algorithm to show the displacement and deflection of the catheter tip. Using an eight variable power electromagnet system around a 250mm sphere of air we have proven the ability of this to accurately move the catheter tip from an initial position to a designated position within the field.","abstract_html":"This thesis represents the initial phase of a proposed operator and patient friendly method designed to semi-automate the positioning and directing of an intravascular catheter in the human heart using a variable electromagnetically induced field to control a catheter tip equipped with three tiny fixed magnets oriented in XYZ planes. Here we demonstrate a comprehensive mathematical model which accurately calculates the magnetic field generated by the electromagnet system, and the magnetic torques and forces exerted on a three-magnet tip catheter. From this we have developed an iterative predictive computer algorithm to show the displacement and deflection of the catheter tip. Using an eight variable power electromagnet system around a 250mm sphere of air we have proven the ability of this to accurately move the catheter tip from an initial position to a designated position within the field.","abstract_has_math":false,"creators":["Le, Vi T. H."],"institution":null,"degree_name":"Master of Computer Science","degree_level":null,"degree_discipline":null,"degree_department":null,"school":null,"contributors":["Professor Kamal Alameh","Dr Hoang Nguyen"],"advisors":[],"committee_chairs":[],"committee_members":[],"year":null,"date_issued":"","date_published":null,"updated_at":"2026-11-27T02:58:57Z","subjects":["magnetically controlled catheter tip","Cardiology","Surgical Procedures, Operative"],"languages":[],"rights":[],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"https://ro.ecu.edu.au/theses/1711","outbound_label":"Repository record","outbound_source":"dc:identifier","record_url":"https://ro.ecu.edu.au/theses/1711","record_label":"Repository record","record_kind":"record","record_source":"dc:identifier","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Aedithcowan%3Aoai%3Aro.ecu.edu.au%3Atheses-2712","prefix":"oai_dc"},"source_record":{"url":"https://ro.ecu.edu.au/do/oai/?verb=GetRecord&metadataPrefix=oai_etdms&identifier=oai%3Aro.ecu.edu.au%3Atheses-2712","prefix":"oai_etdms"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor","label":"Contributor","values":["Professor Kamal Alameh","Dr Hoang Nguyen"]},{"key":"dc:creator","label":"Author","values":["Le, Vi T. H."]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.available","label":"Dc Date Available","values":["2015-11-05T08:00:00Z"]},{"key":"dc:date.created","label":"Dc Date Created","values":["2015-01-01T08:00:00Z"]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Computer Science"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["magnetically controlled catheter tip","Cardiology","Surgical Procedures, Operative"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["https://ro.ecu.edu.au/theses/1711"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["This thesis represents the initial phase of a proposed operator and patient friendly method designed to semi-automate the positioning and directing of an intravascular catheter in the human heart using a variable electromagnetically induced field to control a catheter tip equipped with three tiny fixed magnets oriented in XYZ planes. Here we demonstrate a comprehensive mathematical model which accurately calculates the magnetic field generated by the electromagnet system, and the magnetic torques and forces exerted on a three-magnet tip catheter. From this we have developed an iterative predictive computer algorithm to show the displacement and deflection of the catheter tip. Using an eight variable power electromagnet system around a 250mm sphere of air we have proven the ability of this to accurately move the catheter tip from an initial position to a designated position within the field."]},{"key":"dc:title","label":"Title","values":["Accurate modelling and positioning of a magnetically-controlled catheter tip"]}]}],"canonical_facts":{"dc:contributor":["Professor Kamal Alameh","Dr Hoang Nguyen"],"dc:creator":["Le, Vi T. H."],"dc:date.available":["2015-11-05T08:00:00Z"],"dc:date.created":["2015-01-01T08:00:00Z"],"dc:description.abstract":["This thesis represents the initial phase of a proposed operator and patient friendly method designed to semi-automate the positioning and directing of an intravascular catheter in the human heart using a variable electromagnetically induced field to control a catheter tip equipped with three tiny fixed magnets oriented in XYZ planes. Here we demonstrate a comprehensive mathematical model which accurately calculates the magnetic field generated by the electromagnet system, and the magnetic torques and forces exerted on a three-magnet tip catheter. From this we have developed an iterative predictive computer algorithm to show the displacement and deflection of the catheter tip. Using an eight variable power electromagnet system around a 250mm sphere of air we have proven the ability of this to accurately move the catheter tip from an initial position to a designated position within the field."],"dc:identifier":["https://ro.ecu.edu.au/theses/1711"],"dc:subject":["magnetically controlled catheter tip","Cardiology","Surgical Procedures, Operative"],"dc:title":["Accurate modelling and positioning of a magnetically-controlled catheter tip"],"dc:type":["Thesis"],"thesis:degree_name":["Master of Computer Science"]},"updated_at":"2026-11-27T02:58:57Z"}