{"id":{"repo_id":"edithcowan","oai_identifier":"oai:ro.ecu.edu.au:theses-3942"},"canonical_url":"https://search.ndltd.org/etd/edithcowan/oai:ro.ecu.edu.au:theses-3942","repository":{"repo_id":"edithcowan","name":"Edith Cowan University","base_url":"https://ro.ecu.edu.au/do/oai/"},"display":{"title":"Sliding mode-based load frequency control in interconnected power systems","abstract":"Load frequency control (LFC) in interconnected multiarea power systems has become increasingly challenging due to the integration of renewable energy sources, random load variations, and system uncertainties. These factors contribute to frequency deviations, reduced system inertia, and compromised stability, necessitating robust control mechanisms. This research proposes an advanced sliding mode control (SMC)-based LFC framework, incorporating disturbance observer-based SMC, memory-based adaptive SMC, and event-triggered SMC to enhance system resilience, transient performance, and computational efficiency. A disturbance observer estimates lumped disturbances from tie-line power deviations, load variations, and renewable fluctuations, while a memory-based sliding mode strategy improves frequency stability by leveraging past system states. Additionally, an event-triggered SMC approach with output feedback reduces computational overhead while ensuring robust performance. The proposed framework guarantees globally stable and adaptive frequency regulation through linear matrix inequalities (LMIs) and H∞ robust performance criteria. Integrating an energy storage system (ESS) further enhances disturbance rejection and frequency response. Compared to conventional robust SMC-based LFC methods, the proposed strategy achieves superior disturbance rejection, reducing frequency overshoot, control effort, and response time. Numerical simulations and comparative studies validate the effectiveness of the framework in improving transient stability and decentralized scalability, making it a viable solution for real-world power systems. This research contributes to advancing resilient LFC strategies in renewable-integrated grids, paving the way for more adaptive and efficient grid management approaches.","abstract_html":"Load frequency control (LFC) in interconnected multiarea power systems has become increasingly challenging due to the integration of renewable energy sources, random load variations, and system uncertainties. These factors contribute to frequency deviations, reduced system inertia, and compromised stability, necessitating robust control mechanisms. This research proposes an advanced sliding mode control (SMC)-based LFC framework, incorporating disturbance observer-based SMC, memory-based adaptive SMC, and event-triggered SMC to enhance system resilience, transient performance, and computational efficiency. A disturbance observer estimates lumped disturbances from tie-line power deviations, load variations, and renewable fluctuations, while a memory-based sliding mode strategy improves frequency stability by leveraging past system states. Additionally, an event-triggered SMC approach with output feedback reduces computational overhead while ensuring robust performance. The proposed framework guarantees globally stable and adaptive frequency regulation through linear matrix inequalities (LMIs) and H∞ robust performance criteria. Integrating an energy storage system (ESS) further enhances disturbance rejection and frequency response. Compared to conventional robust SMC-based LFC methods, the proposed strategy achieves superior disturbance rejection, reducing frequency overshoot, control effort, and response time. Numerical simulations and comparative studies validate the effectiveness of the framework in improving transient stability and decentralized scalability, making it a viable solution for real-world power systems. This research contributes to advancing resilient LFC strategies in renewable-integrated grids, paving the way for more adaptive and efficient grid management approaches.","abstract_has_math":false,"creators":["Farivar, Farhad"],"institution":null,"degree_name":"Doctor of Philosophy","degree_level":null,"degree_discipline":null,"degree_department":null,"school":null,"contributors":["Octavian Bass","Daryoush Habibi"],"advisors":[],"committee_chairs":[],"committee_members":[],"year":null,"date_issued":"","date_published":null,"updated_at":"2026-11-27T02:59:07Z","subjects":["Sliding mode control","load frequency control","robust control","linear matrix inequality","renewable energy","Electrical and Computer Engineering","Engineering","Power and Energy"],"languages":[],"rights":[],"rights_urls":[],"identifier_entries":[{"key":"dc:identifier","label":"Identifier","values":["<p>Farhad Farivar: <a href=\"http://orcid.org/0000-0002-3577-4853\">http://orcid.org/0000-0002-3577-4853</a></p>","https://ro.ecu.edu.au/theses/2938"],"render_values":[{"text":"<p>Farhad Farivar: <a href=\"http://orcid.org/0000-0002-3577-4853\">http://orcid.org/0000-0002-3577-4853</a></p>","href":null,"code":true},{"text":"https://ro.ecu.edu.au/theses/2938","href":"https://ro.ecu.edu.au/theses/2938","code":true}]}],"person_identifier_entries":[]},"links":{"outbound_url":"https://doi.org/10.25958/adc2-6h09","outbound_label":"DOI","outbound_source":"dc:identifier","record_url":"https://doi.org/10.25958/adc2-6h09","record_label":"Repository record","record_kind":"doi","record_source":"dc:identifier","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Aedithcowan%3Aoai%3Aro.ecu.edu.au%3Atheses-3942","prefix":"oai_dc"},"source_record":{"url":"https://ro.ecu.edu.au/do/oai/?verb=GetRecord&metadataPrefix=oai_etdms&identifier=oai%3Aro.ecu.edu.au%3Atheses-3942","prefix":"oai_etdms"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor","label":"Contributor","values":["Octavian Bass","Daryoush Habibi"]},{"key":"dc:creator","label":"Author","values":["Farivar, Farhad"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.available","label":"Dc Date Available","values":["2026-07-05T07:00:00Z"]},{"key":"dc:date.created","label":"Dc Date Created","values":["2025-01-01T08:00:00Z"]},{"key":"dc:type","label":"Dc Type","values":["Thesis - ECU Access Only"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Doctor of Philosophy"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Sliding mode control","load frequency control","robust control","linear matrix inequality","renewable energy","Electrical and Computer Engineering","Engineering","Power and Energy"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["<p>Farhad Farivar: <a href=\"http://orcid.org/0000-0002-3577-4853\">http://orcid.org/0000-0002-3577-4853</a></p>","10.25958/adc2-6h09","https://ro.ecu.edu.au/theses/2938"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["Load frequency control (LFC) in interconnected multiarea power systems has become increasingly challenging due to the integration of renewable energy sources, random load variations, and system uncertainties. These factors contribute to frequency deviations, reduced system inertia, and compromised stability, necessitating robust control mechanisms. This research proposes an advanced sliding mode control (SMC)-based LFC framework, incorporating disturbance observer-based SMC, memory-based adaptive SMC, and event-triggered SMC to enhance system resilience, transient performance, and computational efficiency. A disturbance observer estimates lumped disturbances from tie-line power deviations, load variations, and renewable fluctuations, while a memory-based sliding mode strategy improves frequency stability by leveraging past system states. Additionally, an event-triggered SMC approach with output feedback reduces computational overhead while ensuring robust performance. The proposed framework guarantees globally stable and adaptive frequency regulation through linear matrix inequalities (LMIs) and H∞ robust performance criteria. Integrating an energy storage system (ESS) further enhances disturbance rejection and frequency response. Compared to conventional robust SMC-based LFC methods, the proposed strategy achieves superior disturbance rejection, reducing frequency overshoot, control effort, and response time. Numerical simulations and comparative studies validate the effectiveness of the framework in improving transient stability and decentralized scalability, making it a viable solution for real-world power systems. This research contributes to advancing resilient LFC strategies in renewable-integrated grids, paving the way for more adaptive and efficient grid management approaches."]},{"key":"dc:title","label":"Title","values":["Sliding mode-based load frequency control in interconnected power systems"]}]}],"canonical_facts":{"dc:contributor":["Octavian Bass","Daryoush Habibi"],"dc:creator":["Farivar, Farhad"],"dc:date.available":["2026-07-05T07:00:00Z"],"dc:date.created":["2025-01-01T08:00:00Z"],"dc:description.abstract":["Load frequency control (LFC) in interconnected multiarea power systems has become increasingly challenging due to the integration of renewable energy sources, random load variations, and system uncertainties. These factors contribute to frequency deviations, reduced system inertia, and compromised stability, necessitating robust control mechanisms. This research proposes an advanced sliding mode control (SMC)-based LFC framework, incorporating disturbance observer-based SMC, memory-based adaptive SMC, and event-triggered SMC to enhance system resilience, transient performance, and computational efficiency. A disturbance observer estimates lumped disturbances from tie-line power deviations, load variations, and renewable fluctuations, while a memory-based sliding mode strategy improves frequency stability by leveraging past system states. Additionally, an event-triggered SMC approach with output feedback reduces computational overhead while ensuring robust performance. The proposed framework guarantees globally stable and adaptive frequency regulation through linear matrix inequalities (LMIs) and H∞ robust performance criteria. Integrating an energy storage system (ESS) further enhances disturbance rejection and frequency response. Compared to conventional robust SMC-based LFC methods, the proposed strategy achieves superior disturbance rejection, reducing frequency overshoot, control effort, and response time. Numerical simulations and comparative studies validate the effectiveness of the framework in improving transient stability and decentralized scalability, making it a viable solution for real-world power systems. This research contributes to advancing resilient LFC strategies in renewable-integrated grids, paving the way for more adaptive and efficient grid management approaches."],"dc:identifier":["<p>Farhad Farivar: <a href=\"http://orcid.org/0000-0002-3577-4853\">http://orcid.org/0000-0002-3577-4853</a></p>","10.25958/adc2-6h09","https://ro.ecu.edu.au/theses/2938"],"dc:subject":["Sliding mode control","load frequency control","robust control","linear matrix inequality","renewable energy","Electrical and Computer Engineering","Engineering","Power and Energy"],"dc:title":["Sliding mode-based load frequency control in interconnected power systems"],"dc:type":["Thesis - ECU Access Only"],"thesis:degree_name":["Doctor of Philosophy"]},"updated_at":"2026-11-27T02:59:07Z"}