{"id":{"repo_id":"eiu","oai_identifier":"oai:thekeep.eiu.edu:theses-1755"},"canonical_url":"https://search.ndltd.org/etd/eiu/oai:thekeep.eiu.edu:theses-1755","repository":{"repo_id":"eiu","name":"Eastern Illinois University","base_url":"https://thekeep.eiu.edu/do/oai/"},"display":{"title":"The validity of the s/z ratio as a voice screening tool","abstract":"This study investigated the validity of the s/z ratio as a voice screening tool. Twenty female subjects, ten with vocal fold pathology and ten normal control subjects, participated in the current research project. Results indicated that although the s/z ratio was higher for the disordered group than the normal group, the difference was not significant (p=.18). Sensitivity equaled 90% while specificity equaled 50% when 1.1 was used as the cutoff value. When 1.4 was used as the cutoff value, sensitivity was 30% while specificity was 80%. In addition, there was a weak relationship between the clinician's perception of the size of the vocal pathology (roughness of the vocal folds) and the s/z value for the vocal pathology group. Overall, results indicated that the s/z ratio was not a reliable screening tool to differentiate 10 participants who present with vocal fold pathology and 10 participants without vocal fold pathology.","abstract_html":"This study investigated the validity of the s/z ratio as a voice screening tool. Twenty female subjects, ten with vocal fold pathology and ten normal control subjects, participated in the current research project. Results indicated that although the s/z ratio was higher for the disordered group than the normal group, the difference was not significant (p=.18). Sensitivity equaled 90% while specificity equaled 50% when 1.1 was used as the cutoff value. When 1.4 was used as the cutoff value, sensitivity was 30% while specificity was 80%. In addition, there was a weak relationship between the clinician&#x27;s perception of the size of the vocal pathology (roughness of the vocal folds) and the s/z value for the vocal pathology group. Overall, results indicated that the s/z ratio was not a reliable screening tool to differentiate 10 participants who present with vocal fold pathology and 10 participants without vocal fold pathology.","abstract_has_math":false,"creators":["Panozzo, Larry L., Jr."],"institution":null,"degree_name":"Master of Science (MS)","degree_level":null,"degree_discipline":"Communication Disorders and Sciences","degree_department":null,"school":null,"contributors":["Rebecca Throneburg","Frank Goldacker","Mary Anne Hanner"],"advisors":[],"committee_chairs":[],"committee_members":[],"year":null,"date_issued":"","date_published":null,"updated_at":"2026-11-19T07:55:19Z","subjects":["Communication Sciences and Disorders"],"languages":[],"rights":[],"rights_urls":["http://creativecommons.org/licenses/by-nc-nd/3.0/"],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"https://thekeep.eiu.edu/theses/756","outbound_label":"Repository record","outbound_source":"dc:identifier","record_url":"https://thekeep.eiu.edu/theses/756","record_label":"Repository record","record_kind":"record","record_source":"dc:identifier","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://thekeep.eiu.edu/do/oai/?verb=GetRecord&metadataPrefix=oai_etdms&identifier=oai%3Athekeep.eiu.edu%3Atheses-1755","prefix":"oai_etdms"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor","label":"Contributor","values":["Rebecca Throneburg","Frank Goldacker","Mary Anne Hanner"]},{"key":"dc:creator","label":"Author","values":["Panozzo, Larry L., Jr."]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.available","label":"Dc Date Available","values":["2012-04-13T07:00:00Z"]},{"key":"dc:date.created","label":"Dc Date Created","values":["2006-01-01T08:00:00Z"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Communication Disorders and Sciences"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Science (MS)"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Communication Sciences and Disorders"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:rights.license","label":"Dc Rights License","values":["http://creativecommons.org/licenses/by-nc-nd/3.0/"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["https://thekeep.eiu.edu/theses/756"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["This study investigated the validity of the s/z ratio as a voice screening tool. Twenty female subjects, ten with vocal fold pathology and ten normal control subjects, participated in the current research project. Results indicated that although the s/z ratio was higher for the disordered group than the normal group, the difference was not significant (p=.18). Sensitivity equaled 90% while specificity equaled 50% when 1.1 was used as the cutoff value. When 1.4 was used as the cutoff value, sensitivity was 30% while specificity was 80%. In addition, there was a weak relationship between the clinician's perception of the size of the vocal pathology (roughness of the vocal folds) and the s/z value for the vocal pathology group. Overall, results indicated that the s/z ratio was not a reliable screening tool to differentiate 10 participants who present with vocal fold pathology and 10 participants without vocal fold pathology."]},{"key":"dc:title","label":"Title","values":["The validity of the s/z ratio as a voice screening tool"]}]}],"canonical_facts":{"dc:contributor":["Rebecca Throneburg","Frank Goldacker","Mary Anne Hanner"],"dc:creator":["Panozzo, Larry L., Jr."],"dc:date.available":["2012-04-13T07:00:00Z"],"dc:date.created":["2006-01-01T08:00:00Z"],"dc:description.abstract":["This study investigated the validity of the s/z ratio as a voice screening tool. Twenty female subjects, ten with vocal fold pathology and ten normal control subjects, participated in the current research project. Results indicated that although the s/z ratio was higher for the disordered group than the normal group, the difference was not significant (p=.18). Sensitivity equaled 90% while specificity equaled 50% when 1.1 was used as the cutoff value. When 1.4 was used as the cutoff value, sensitivity was 30% while specificity was 80%. In addition, there was a weak relationship between the clinician's perception of the size of the vocal pathology (roughness of the vocal folds) and the s/z value for the vocal pathology group. Overall, results indicated that the s/z ratio was not a reliable screening tool to differentiate 10 participants who present with vocal fold pathology and 10 participants without vocal fold pathology."],"dc:identifier":["https://thekeep.eiu.edu/theses/756"],"dc:rights.license":["http://creativecommons.org/licenses/by-nc-nd/3.0/"],"dc:subject":["Communication Sciences and Disorders"],"dc:title":["The validity of the s/z ratio as a voice screening tool"],"thesis:degree_discipline":["Communication Disorders and Sciences"],"thesis:degree_name":["Master of Science (MS)"]},"updated_at":"2026-11-19T07:55:19Z"}